Experimental Investigation the effect of slot on bed scouring in Series Triangular of Vane Attached to The Bank in 90 Degree Mild Bend

Triangular vanes attached to the bank are a new method to control erosion and help protection the bank in meandering rivers. This structure is subjected to scouring due to flow convergence at the tips of the structures. Therefore, countermeasure methods should be employed in order to prevent financi...

Full description

Bibliographic Details
Main Authors: Mohsen Dorosti, Ahmad fathi, Mohammad Mahmoodian Shooshtari
Format: Article
Language:fas
Published: Shahid Chamran University of Ahvaz 1970-01-01
Series:علوم و مهندسی آبیاری
Subjects:
Online Access:http://jise.scu.ac.ir/article_12971_4f84e1c585d506ed271c84657369da31.pdf
_version_ 1818684500598587392
author Mohsen Dorosti
Ahmad fathi
Mohammad Mahmoodian Shooshtari
author_facet Mohsen Dorosti
Ahmad fathi
Mohammad Mahmoodian Shooshtari
author_sort Mohsen Dorosti
collection DOAJ
description Triangular vanes attached to the bank are a new method to control erosion and help protection the bank in meandering rivers. This structure is subjected to scouring due to flow convergence at the tips of the structures. Therefore, countermeasure methods should be employed in order to prevent financial damages and life hazards. One of these methods is to use a slot. In this study, the series of triangular vanes that a parallel chord rectangular slot, with the opening of the full vane area of 10% and a ratio of a/b=4 (a and b are the length and width of the slot) the bed in which they are established position near has been used. The vanes angle is 30 degrees upstream of the bank. Experiments under different installation distances, 4, 6 and 8 times the effective vane length, hydraulic conditions are different (Froude number 0.287, 0.304, 0.322), and the clear water. In all experiments depth of flow is constant and equal to 14 cm. Then the results were compared with no slot. The results showed that the slot reduces the average depths of scour around the tips of vanes. In average, the reduce percent of the average scour depths around the tips of the structure in distances 4Le, 6Le and 8Le is equal to 9 percent, 17 percent and 18 percent respectively. The triangular vanes caused flow diversion from outer bank towards the center bend and thus the formation of thalweg. The slot reduces the maximum depth of scour thalweg. In average, the reduce percent of the maximum depth of scour thalweg in distances 4Le, 6Le and 8Le is equal to 22.6 percent, 46 percent and 30 percent respectively. The first of effective length of vanes was 1/5 flume wide. In start tests and erosion around the vanes increased the first of effective length of vanes. The slot reduces the effective length variation of vanes. In average, the reduce percent of average the effective length variation of vanes in distances 4Le, 6Le and 8Le is equal to 15.5 percent, 13.7 percent and 15.7 percent respectively.
first_indexed 2024-12-17T10:51:37Z
format Article
id doaj.art-aeb864134dd8473b90435d8db23b1983
institution Directory Open Access Journal
issn 2588-5952
2588-5960
language fas
last_indexed 2024-12-17T10:51:37Z
publishDate 1970-01-01
publisher Shahid Chamran University of Ahvaz
record_format Article
series علوم و مهندسی آبیاری
spelling doaj.art-aeb864134dd8473b90435d8db23b19832022-12-21T21:51:57ZfasShahid Chamran University of Ahvazعلوم و مهندسی آبیاری2588-59522588-59601970-01-01401-124926010.22055/jise.2017.1297112971Experimental Investigation the effect of slot on bed scouring in Series Triangular of Vane Attached to The Bank in 90 Degree Mild BendMohsen Dorosti0Ahmad fathi1Mohammad Mahmoodian Shooshtari2دانشجوی کارشناسی‌ارشد سازه‌های آبی، دانشکده مهندسی علوم آب، دانشگاه شهید چمران اهوازUniversity of Ahvaz,Iranاستاد بازنشته گروه عمران، دانشکده مهندسی دانشگاه شهید چمران اهوازTriangular vanes attached to the bank are a new method to control erosion and help protection the bank in meandering rivers. This structure is subjected to scouring due to flow convergence at the tips of the structures. Therefore, countermeasure methods should be employed in order to prevent financial damages and life hazards. One of these methods is to use a slot. In this study, the series of triangular vanes that a parallel chord rectangular slot, with the opening of the full vane area of 10% and a ratio of a/b=4 (a and b are the length and width of the slot) the bed in which they are established position near has been used. The vanes angle is 30 degrees upstream of the bank. Experiments under different installation distances, 4, 6 and 8 times the effective vane length, hydraulic conditions are different (Froude number 0.287, 0.304, 0.322), and the clear water. In all experiments depth of flow is constant and equal to 14 cm. Then the results were compared with no slot. The results showed that the slot reduces the average depths of scour around the tips of vanes. In average, the reduce percent of the average scour depths around the tips of the structure in distances 4Le, 6Le and 8Le is equal to 9 percent, 17 percent and 18 percent respectively. The triangular vanes caused flow diversion from outer bank towards the center bend and thus the formation of thalweg. The slot reduces the maximum depth of scour thalweg. In average, the reduce percent of the maximum depth of scour thalweg in distances 4Le, 6Le and 8Le is equal to 22.6 percent, 46 percent and 30 percent respectively. The first of effective length of vanes was 1/5 flume wide. In start tests and erosion around the vanes increased the first of effective length of vanes. The slot reduces the effective length variation of vanes. In average, the reduce percent of average the effective length variation of vanes in distances 4Le, 6Le and 8Le is equal to 15.5 percent, 13.7 percent and 15.7 percent respectively.http://jise.scu.ac.ir/article_12971_4f84e1c585d506ed271c84657369da31.pdfslottriangular vanesbed scouring90 degree mild bend
spellingShingle Mohsen Dorosti
Ahmad fathi
Mohammad Mahmoodian Shooshtari
Experimental Investigation the effect of slot on bed scouring in Series Triangular of Vane Attached to The Bank in 90 Degree Mild Bend
علوم و مهندسی آبیاری
slot
triangular vanes
bed scouring
90 degree mild bend
title Experimental Investigation the effect of slot on bed scouring in Series Triangular of Vane Attached to The Bank in 90 Degree Mild Bend
title_full Experimental Investigation the effect of slot on bed scouring in Series Triangular of Vane Attached to The Bank in 90 Degree Mild Bend
title_fullStr Experimental Investigation the effect of slot on bed scouring in Series Triangular of Vane Attached to The Bank in 90 Degree Mild Bend
title_full_unstemmed Experimental Investigation the effect of slot on bed scouring in Series Triangular of Vane Attached to The Bank in 90 Degree Mild Bend
title_short Experimental Investigation the effect of slot on bed scouring in Series Triangular of Vane Attached to The Bank in 90 Degree Mild Bend
title_sort experimental investigation the effect of slot on bed scouring in series triangular of vane attached to the bank in 90 degree mild bend
topic slot
triangular vanes
bed scouring
90 degree mild bend
url http://jise.scu.ac.ir/article_12971_4f84e1c585d506ed271c84657369da31.pdf
work_keys_str_mv AT mohsendorosti experimentalinvestigationtheeffectofslotonbedscouringinseriestriangularofvaneattachedtothebankin90degreemildbend
AT ahmadfathi experimentalinvestigationtheeffectofslotonbedscouringinseriestriangularofvaneattachedtothebankin90degreemildbend
AT mohammadmahmoodianshooshtari experimentalinvestigationtheeffectofslotonbedscouringinseriestriangularofvaneattachedtothebankin90degreemildbend