A Rapid RT-LAMP Assay for SARS-CoV-2 with Colorimetric Detection Assisted by a Mobile Application

Loop-mediated amplification has been promoted for SARS-CoV-2 screening, however, antigen tests are preferred in low-income countries and remote zones. Poor training in molecular biology, plus the need for RNA purification or reading instruments to overcome issues of sensitivity in colorimetric detec...

Full description

Bibliographic Details
Main Authors: María Aurora Londono-Avendano, Gerardo Libreros, Lyda Osorio, Beatriz Parra
Format: Article
Language:English
Published: MDPI AG 2022-03-01
Series:Diagnostics
Subjects:
Online Access:https://www.mdpi.com/2075-4418/12/4/848
_version_ 1827621069106708480
author María Aurora Londono-Avendano
Gerardo Libreros
Lyda Osorio
Beatriz Parra
author_facet María Aurora Londono-Avendano
Gerardo Libreros
Lyda Osorio
Beatriz Parra
author_sort María Aurora Londono-Avendano
collection DOAJ
description Loop-mediated amplification has been promoted for SARS-CoV-2 screening, however, antigen tests are preferred in low-income countries and remote zones. Poor training in molecular biology, plus the need for RNA purification or reading instruments to overcome issues of sensitivity in colorimetric detection, are some of the reasons limiting the use of this technique. In this study, nasopharyngeal swabs, aspirates and saliva were amplified in an in-house LAMP assay and subject to colorimetric detection, achieved by the naked eye and by image analysis with a mobile application. Accuracy of detection by the naked eye ranged from 61–74% but improved to 75–86% when using the application. Sensitivity of the digital approach was 81% and specificity 83%, with poor positive predictive value, and acceptable negative predictive value. Additionally to the reported effect of some transport media’s pH, the presence of mucus and warming up of reagents while setting up the reaction critically affected performance. Accuracy per type of sample was 55, 70 and 80%, for swabs, aspirates and saliva, respectively, suggesting potential to improve the test in saliva. This assay, carried out in a closed tube, reduces contamination, has few pipetting steps and requires minimal equipment. Strategies to improve performance and implications of the use this sort of colorimetric LAMP for massive testing are discussed.
first_indexed 2024-03-09T10:57:30Z
format Article
id doaj.art-aef9063eb53a46a9aab1b7ccb7ca8692
institution Directory Open Access Journal
issn 2075-4418
language English
last_indexed 2024-03-09T10:57:30Z
publishDate 2022-03-01
publisher MDPI AG
record_format Article
series Diagnostics
spelling doaj.art-aef9063eb53a46a9aab1b7ccb7ca86922023-12-01T01:31:33ZengMDPI AGDiagnostics2075-44182022-03-0112484810.3390/diagnostics12040848A Rapid RT-LAMP Assay for SARS-CoV-2 with Colorimetric Detection Assisted by a Mobile ApplicationMaría Aurora Londono-Avendano0Gerardo Libreros1Lyda Osorio2Beatriz Parra3Departamento de Microbiología, Escuela de Ciencias Básicas, Facultad de Salud, Universidad del Valle, Calle 4B # 36-00, edificio 120, oficina 223/229, Cali 760043, ColombiaDepartamento de Microbiología, Escuela de Ciencias Básicas, Facultad de Salud, Universidad del Valle, Calle 4B # 36-00, edificio 120, oficina 223/229, Cali 760043, ColombiaEscuela de Salud Pública, Facultad de Salud, Universidad del Valle, Calle 4B # 36-00, edificio 120, oficina 223/229, Cali 760043, ColombiaDepartamento de Microbiología, Escuela de Ciencias Básicas, Facultad de Salud, Universidad del Valle, Calle 4B # 36-00, edificio 120, oficina 223/229, Cali 760043, ColombiaLoop-mediated amplification has been promoted for SARS-CoV-2 screening, however, antigen tests are preferred in low-income countries and remote zones. Poor training in molecular biology, plus the need for RNA purification or reading instruments to overcome issues of sensitivity in colorimetric detection, are some of the reasons limiting the use of this technique. In this study, nasopharyngeal swabs, aspirates and saliva were amplified in an in-house LAMP assay and subject to colorimetric detection, achieved by the naked eye and by image analysis with a mobile application. Accuracy of detection by the naked eye ranged from 61–74% but improved to 75–86% when using the application. Sensitivity of the digital approach was 81% and specificity 83%, with poor positive predictive value, and acceptable negative predictive value. Additionally to the reported effect of some transport media’s pH, the presence of mucus and warming up of reagents while setting up the reaction critically affected performance. Accuracy per type of sample was 55, 70 and 80%, for swabs, aspirates and saliva, respectively, suggesting potential to improve the test in saliva. This assay, carried out in a closed tube, reduces contamination, has few pipetting steps and requires minimal equipment. Strategies to improve performance and implications of the use this sort of colorimetric LAMP for massive testing are discussed.https://www.mdpi.com/2075-4418/12/4/848SARS-CoV-2COVID-19isothermal amplificationcolorimetrycell phone application
spellingShingle María Aurora Londono-Avendano
Gerardo Libreros
Lyda Osorio
Beatriz Parra
A Rapid RT-LAMP Assay for SARS-CoV-2 with Colorimetric Detection Assisted by a Mobile Application
Diagnostics
SARS-CoV-2
COVID-19
isothermal amplification
colorimetry
cell phone application
title A Rapid RT-LAMP Assay for SARS-CoV-2 with Colorimetric Detection Assisted by a Mobile Application
title_full A Rapid RT-LAMP Assay for SARS-CoV-2 with Colorimetric Detection Assisted by a Mobile Application
title_fullStr A Rapid RT-LAMP Assay for SARS-CoV-2 with Colorimetric Detection Assisted by a Mobile Application
title_full_unstemmed A Rapid RT-LAMP Assay for SARS-CoV-2 with Colorimetric Detection Assisted by a Mobile Application
title_short A Rapid RT-LAMP Assay for SARS-CoV-2 with Colorimetric Detection Assisted by a Mobile Application
title_sort rapid rt lamp assay for sars cov 2 with colorimetric detection assisted by a mobile application
topic SARS-CoV-2
COVID-19
isothermal amplification
colorimetry
cell phone application
url https://www.mdpi.com/2075-4418/12/4/848
work_keys_str_mv AT mariaauroralondonoavendano arapidrtlampassayforsarscov2withcolorimetricdetectionassistedbyamobileapplication
AT gerardolibreros arapidrtlampassayforsarscov2withcolorimetricdetectionassistedbyamobileapplication
AT lydaosorio arapidrtlampassayforsarscov2withcolorimetricdetectionassistedbyamobileapplication
AT beatrizparra arapidrtlampassayforsarscov2withcolorimetricdetectionassistedbyamobileapplication
AT mariaauroralondonoavendano rapidrtlampassayforsarscov2withcolorimetricdetectionassistedbyamobileapplication
AT gerardolibreros rapidrtlampassayforsarscov2withcolorimetricdetectionassistedbyamobileapplication
AT lydaosorio rapidrtlampassayforsarscov2withcolorimetricdetectionassistedbyamobileapplication
AT beatrizparra rapidrtlampassayforsarscov2withcolorimetricdetectionassistedbyamobileapplication