The Effect of Liposuction Cannula Diameter on Fat Retention—Based on a Rheological Simulation

Background:. Autologous fat is considered as an ideal material for soft-tissue augmentation in plastic and reconstructive surgery. The primary drawback of autologous fat grafting is the high absorption rate, thus fat retention is considered as an essential indicator. There are several researches abo...

Full description

Bibliographic Details
Main Authors: Yuanren Tong, Penghao Liu, Yuneng Wang, Chang Geng, Xuefeng Han, MD, PhD, Jiguang Ma, MD, Facheng Li, MD, PhD, Lei Cai, MD, PhD
Format: Article
Language:English
Published: Wolters Kluwer 2018-11-01
Series:Plastic and Reconstructive Surgery, Global Open
Online Access:http://journals.lww.com/prsgo/fulltext/10.1097/GOX.0000000000002021
_version_ 1819262739930939392
author Yuanren Tong
Penghao Liu
Yuneng Wang
Chang Geng
Xuefeng Han, MD, PhD
Jiguang Ma, MD
Facheng Li, MD, PhD
Lei Cai, MD, PhD
author_facet Yuanren Tong
Penghao Liu
Yuneng Wang
Chang Geng
Xuefeng Han, MD, PhD
Jiguang Ma, MD
Facheng Li, MD, PhD
Lei Cai, MD, PhD
author_sort Yuanren Tong
collection DOAJ
description Background:. Autologous fat is considered as an ideal material for soft-tissue augmentation in plastic and reconstructive surgery. The primary drawback of autologous fat grafting is the high absorption rate, thus fat retention is considered as an essential indicator. There are several researches about the factors that can influence fat retention, including centrifugation and cannula size. However, rheological models of cannula during liposuction are limited. This research focuses on the effects of cannulas with diameters of 2 mm and 2.5 mm on fat retention, which is based on a rheological simulation of inlet pressure and maximum velocity. Experiments on mice were also conducted to confirm the result from the simulation. Methods:. A simulation was conducted with the physical parameters of the adipose tissue. Human lipoaspirate samples were obtained from patients by liposuction through cannulas of different diameters and were transferred into subcutaneous tissue of nude mice, a part of which were used in viscosity and density measurement. Graft retention was measured and fat quality was assessed through histologic analysis after 6 months. Results:. Viscosity and density of the fat tissue had significant effects on fat retention. The 2.5 mm diameter cannula had significantly lower inlet pressure and maximum velocity and thus led to higher graft retention, but oil cystic nodules appeared meanwhile. Conclusions:. Cannulas with larger diameters have lower inlet pressure and maximum velocity during the liposuction process, which further influences the viability of adipocytes and adipose stem cells and thus has larger fat graft retention. This research built a mathematical model with less bias than in vivo experiments and provides a general way for analyzing the outcome of a liposuction precisely, which adds to the data for cannula optimization.
first_indexed 2024-12-23T20:02:29Z
format Article
id doaj.art-af4ad82cb3f345e7bd0a55af17ff2409
institution Directory Open Access Journal
issn 2169-7574
language English
last_indexed 2024-12-23T20:02:29Z
publishDate 2018-11-01
publisher Wolters Kluwer
record_format Article
series Plastic and Reconstructive Surgery, Global Open
spelling doaj.art-af4ad82cb3f345e7bd0a55af17ff24092022-12-21T17:33:03ZengWolters KluwerPlastic and Reconstructive Surgery, Global Open2169-75742018-11-01611e202110.1097/GOX.0000000000002021201811000-00021The Effect of Liposuction Cannula Diameter on Fat Retention—Based on a Rheological SimulationYuanren Tong0Penghao Liu1Yuneng Wang2Chang Geng3Xuefeng Han, MD, PhD4Jiguang Ma, MD5Facheng Li, MD, PhD6Lei Cai, MD, PhD7From the *Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, ChinaFrom the *Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China†Department of Body Contouring and Fat Grafting Center of Plastic Surgery Hospital of Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, ChinaFrom the *Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China†Department of Body Contouring and Fat Grafting Center of Plastic Surgery Hospital of Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China‡Department of Aesthetic Face and Neck Plastic Surgery Center of Plastic Surgery Hospital of Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China.†Department of Body Contouring and Fat Grafting Center of Plastic Surgery Hospital of Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China†Department of Body Contouring and Fat Grafting Center of Plastic Surgery Hospital of Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, ChinaBackground:. Autologous fat is considered as an ideal material for soft-tissue augmentation in plastic and reconstructive surgery. The primary drawback of autologous fat grafting is the high absorption rate, thus fat retention is considered as an essential indicator. There are several researches about the factors that can influence fat retention, including centrifugation and cannula size. However, rheological models of cannula during liposuction are limited. This research focuses on the effects of cannulas with diameters of 2 mm and 2.5 mm on fat retention, which is based on a rheological simulation of inlet pressure and maximum velocity. Experiments on mice were also conducted to confirm the result from the simulation. Methods:. A simulation was conducted with the physical parameters of the adipose tissue. Human lipoaspirate samples were obtained from patients by liposuction through cannulas of different diameters and were transferred into subcutaneous tissue of nude mice, a part of which were used in viscosity and density measurement. Graft retention was measured and fat quality was assessed through histologic analysis after 6 months. Results:. Viscosity and density of the fat tissue had significant effects on fat retention. The 2.5 mm diameter cannula had significantly lower inlet pressure and maximum velocity and thus led to higher graft retention, but oil cystic nodules appeared meanwhile. Conclusions:. Cannulas with larger diameters have lower inlet pressure and maximum velocity during the liposuction process, which further influences the viability of adipocytes and adipose stem cells and thus has larger fat graft retention. This research built a mathematical model with less bias than in vivo experiments and provides a general way for analyzing the outcome of a liposuction precisely, which adds to the data for cannula optimization.http://journals.lww.com/prsgo/fulltext/10.1097/GOX.0000000000002021
spellingShingle Yuanren Tong
Penghao Liu
Yuneng Wang
Chang Geng
Xuefeng Han, MD, PhD
Jiguang Ma, MD
Facheng Li, MD, PhD
Lei Cai, MD, PhD
The Effect of Liposuction Cannula Diameter on Fat Retention—Based on a Rheological Simulation
Plastic and Reconstructive Surgery, Global Open
title The Effect of Liposuction Cannula Diameter on Fat Retention—Based on a Rheological Simulation
title_full The Effect of Liposuction Cannula Diameter on Fat Retention—Based on a Rheological Simulation
title_fullStr The Effect of Liposuction Cannula Diameter on Fat Retention—Based on a Rheological Simulation
title_full_unstemmed The Effect of Liposuction Cannula Diameter on Fat Retention—Based on a Rheological Simulation
title_short The Effect of Liposuction Cannula Diameter on Fat Retention—Based on a Rheological Simulation
title_sort effect of liposuction cannula diameter on fat retention based on a rheological simulation
url http://journals.lww.com/prsgo/fulltext/10.1097/GOX.0000000000002021
work_keys_str_mv AT yuanrentong theeffectofliposuctioncannuladiameteronfatretentionbasedonarheologicalsimulation
AT penghaoliu theeffectofliposuctioncannuladiameteronfatretentionbasedonarheologicalsimulation
AT yunengwang theeffectofliposuctioncannuladiameteronfatretentionbasedonarheologicalsimulation
AT changgeng theeffectofliposuctioncannuladiameteronfatretentionbasedonarheologicalsimulation
AT xuefenghanmdphd theeffectofliposuctioncannuladiameteronfatretentionbasedonarheologicalsimulation
AT jiguangmamd theeffectofliposuctioncannuladiameteronfatretentionbasedonarheologicalsimulation
AT fachenglimdphd theeffectofliposuctioncannuladiameteronfatretentionbasedonarheologicalsimulation
AT leicaimdphd theeffectofliposuctioncannuladiameteronfatretentionbasedonarheologicalsimulation
AT yuanrentong effectofliposuctioncannuladiameteronfatretentionbasedonarheologicalsimulation
AT penghaoliu effectofliposuctioncannuladiameteronfatretentionbasedonarheologicalsimulation
AT yunengwang effectofliposuctioncannuladiameteronfatretentionbasedonarheologicalsimulation
AT changgeng effectofliposuctioncannuladiameteronfatretentionbasedonarheologicalsimulation
AT xuefenghanmdphd effectofliposuctioncannuladiameteronfatretentionbasedonarheologicalsimulation
AT jiguangmamd effectofliposuctioncannuladiameteronfatretentionbasedonarheologicalsimulation
AT fachenglimdphd effectofliposuctioncannuladiameteronfatretentionbasedonarheologicalsimulation
AT leicaimdphd effectofliposuctioncannuladiameteronfatretentionbasedonarheologicalsimulation