Application research of high reliability time unified system based on PTP strategy

Nowadays, the performance requirements of time unified system in various fields are getting higher and higher. In the past, most time unified system used NTP for time synchronization, but the protocol can only provide millisecond-level synchronization accuracy, and the master clock is generally fixe...

Full description

Bibliographic Details
Main Authors: Ma Zhao, Ge Wenshuang, Hu Ailan, Zhang Ruiquan, Zhang Zhicheng
Format: Article
Language:zho
Published: National Computer System Engineering Research Institute of China 2019-05-01
Series:Dianzi Jishu Yingyong
Subjects:
Online Access:http://www.chinaaet.com/article/3000101330
_version_ 1818695072491765760
author Ma Zhao
Ge Wenshuang
Hu Ailan
Zhang Ruiquan
Zhang Zhicheng
author_facet Ma Zhao
Ge Wenshuang
Hu Ailan
Zhang Ruiquan
Zhang Zhicheng
author_sort Ma Zhao
collection DOAJ
description Nowadays, the performance requirements of time unified system in various fields are getting higher and higher. In the past, most time unified system used NTP for time synchronization, but the protocol can only provide millisecond-level synchronization accuracy, and the master clock is generally fixed, which cannot meet the requirements of high precision and high robustness in application fields such as measurement and control. Based on this, this paper conducts an in-depth study on the application of high-reliability time unified system based on PTP timing. The system adopts the PTP protocol for timing, which can make the system time synchronization precision reach nanosecond level, and based on the BMC algorithm,the system is designed and implemented the double mode of manual setting and automatic selection for the dual-system hot standby function, which satisfies the high-performance requirements of the time unified system in the application fields such as measurement and control. Compared with the previous time unified system, the system greatly improves the timing accuracy and robustness of time unified system.
first_indexed 2024-12-17T13:39:39Z
format Article
id doaj.art-afcc637bb2ed4383a835223c81abb538
institution Directory Open Access Journal
issn 0258-7998
language zho
last_indexed 2024-12-17T13:39:39Z
publishDate 2019-05-01
publisher National Computer System Engineering Research Institute of China
record_format Article
series Dianzi Jishu Yingyong
spelling doaj.art-afcc637bb2ed4383a835223c81abb5382022-12-21T21:46:21ZzhoNational Computer System Engineering Research Institute of ChinaDianzi Jishu Yingyong0258-79982019-05-01455384210.16157/j.issn.0258-7998.1901613000101330Application research of high reliability time unified system based on PTP strategyMa Zhao0Ge Wenshuang1Hu Ailan2Zhang Ruiquan3Zhang Zhicheng4National Computer System Engineering Research Institute of China,Beijing 100083,ChinaNational Computer System Engineering Research Institute of China,Beijing 100083,ChinaNational Computer System Engineering Research Institute of China,Beijing 100083,ChinaNational Computer System Engineering Research Institute of China,Beijing 100083,ChinaNational Computer System Engineering Research Institute of China,Beijing 100083,ChinaNowadays, the performance requirements of time unified system in various fields are getting higher and higher. In the past, most time unified system used NTP for time synchronization, but the protocol can only provide millisecond-level synchronization accuracy, and the master clock is generally fixed, which cannot meet the requirements of high precision and high robustness in application fields such as measurement and control. Based on this, this paper conducts an in-depth study on the application of high-reliability time unified system based on PTP timing. The system adopts the PTP protocol for timing, which can make the system time synchronization precision reach nanosecond level, and based on the BMC algorithm,the system is designed and implemented the double mode of manual setting and automatic selection for the dual-system hot standby function, which satisfies the high-performance requirements of the time unified system in the application fields such as measurement and control. Compared with the previous time unified system, the system greatly improves the timing accuracy and robustness of time unified system.http://www.chinaaet.com/article/3000101330high precision timingPTPdual-system hot standbytime unified systemmeasurement and control
spellingShingle Ma Zhao
Ge Wenshuang
Hu Ailan
Zhang Ruiquan
Zhang Zhicheng
Application research of high reliability time unified system based on PTP strategy
Dianzi Jishu Yingyong
high precision timing
PTP
dual-system hot standby
time unified system
measurement and control
title Application research of high reliability time unified system based on PTP strategy
title_full Application research of high reliability time unified system based on PTP strategy
title_fullStr Application research of high reliability time unified system based on PTP strategy
title_full_unstemmed Application research of high reliability time unified system based on PTP strategy
title_short Application research of high reliability time unified system based on PTP strategy
title_sort application research of high reliability time unified system based on ptp strategy
topic high precision timing
PTP
dual-system hot standby
time unified system
measurement and control
url http://www.chinaaet.com/article/3000101330
work_keys_str_mv AT mazhao applicationresearchofhighreliabilitytimeunifiedsystembasedonptpstrategy
AT gewenshuang applicationresearchofhighreliabilitytimeunifiedsystembasedonptpstrategy
AT huailan applicationresearchofhighreliabilitytimeunifiedsystembasedonptpstrategy
AT zhangruiquan applicationresearchofhighreliabilitytimeunifiedsystembasedonptpstrategy
AT zhangzhicheng applicationresearchofhighreliabilitytimeunifiedsystembasedonptpstrategy