Noncontact Respiratory Monitoring Using Depth Sensing Cameras: A Review of Current Literature
There is considerable interest in the noncontact monitoring of patients as it allows for reduced restriction of patients, the avoidance of single-use consumables and less patient–clinician contact and hence the reduction of the spread of disease. A technology that has come to the fore for noncontact...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-02-01
|
Series: | Sensors |
Subjects: | |
Online Access: | https://www.mdpi.com/1424-8220/21/4/1135 |
_version_ | 1797413760433913856 |
---|---|
author | Anthony P. Addison Paul S. Addison Philip Smit Dominique Jacquel Ulf R. Borg |
author_facet | Anthony P. Addison Paul S. Addison Philip Smit Dominique Jacquel Ulf R. Borg |
author_sort | Anthony P. Addison |
collection | DOAJ |
description | There is considerable interest in the noncontact monitoring of patients as it allows for reduced restriction of patients, the avoidance of single-use consumables and less patient–clinician contact and hence the reduction of the spread of disease. A technology that has come to the fore for noncontact respiratory monitoring is that based on depth sensing camera systems. This has great potential for the monitoring of a range of respiratory information including the provision of a respiratory waveform, the calculation of respiratory rate and tidal volume (and hence minute volume). Respiratory patterns and apneas can also be observed in the signal. Here we review the ability of this method to provide accurate and clinically useful respiratory information. |
first_indexed | 2024-03-09T05:23:35Z |
format | Article |
id | doaj.art-afcf26e6134c45f5b5011c94c4db2c9e |
institution | Directory Open Access Journal |
issn | 1424-8220 |
language | English |
last_indexed | 2024-03-09T05:23:35Z |
publishDate | 2021-02-01 |
publisher | MDPI AG |
record_format | Article |
series | Sensors |
spelling | doaj.art-afcf26e6134c45f5b5011c94c4db2c9e2023-12-03T12:39:10ZengMDPI AGSensors1424-82202021-02-01214113510.3390/s21041135Noncontact Respiratory Monitoring Using Depth Sensing Cameras: A Review of Current LiteratureAnthony P. Addison0Paul S. Addison1Philip Smit2Dominique Jacquel3Ulf R. Borg4Medtronic, Video Biosignals Group, Patient Monitoring, Edinburgh EH26 0PJ, UKMedtronic, Video Biosignals Group, Patient Monitoring, Edinburgh EH26 0PJ, UKMedtronic, Video Biosignals Group, Patient Monitoring, Edinburgh EH26 0PJ, UKMedtronic, Video Biosignals Group, Patient Monitoring, Edinburgh EH26 0PJ, UKMedtronic, Medical Affairs, Patient Monitoring, Boulder, CO 80301, USAThere is considerable interest in the noncontact monitoring of patients as it allows for reduced restriction of patients, the avoidance of single-use consumables and less patient–clinician contact and hence the reduction of the spread of disease. A technology that has come to the fore for noncontact respiratory monitoring is that based on depth sensing camera systems. This has great potential for the monitoring of a range of respiratory information including the provision of a respiratory waveform, the calculation of respiratory rate and tidal volume (and hence minute volume). Respiratory patterns and apneas can also be observed in the signal. Here we review the ability of this method to provide accurate and clinically useful respiratory information.https://www.mdpi.com/1424-8220/21/4/1135noncontact monitoringdepth-sensing camerarespiratory monitoringrespiratory ratetidal volumerespiratory patterns |
spellingShingle | Anthony P. Addison Paul S. Addison Philip Smit Dominique Jacquel Ulf R. Borg Noncontact Respiratory Monitoring Using Depth Sensing Cameras: A Review of Current Literature Sensors noncontact monitoring depth-sensing camera respiratory monitoring respiratory rate tidal volume respiratory patterns |
title | Noncontact Respiratory Monitoring Using Depth Sensing Cameras: A Review of Current Literature |
title_full | Noncontact Respiratory Monitoring Using Depth Sensing Cameras: A Review of Current Literature |
title_fullStr | Noncontact Respiratory Monitoring Using Depth Sensing Cameras: A Review of Current Literature |
title_full_unstemmed | Noncontact Respiratory Monitoring Using Depth Sensing Cameras: A Review of Current Literature |
title_short | Noncontact Respiratory Monitoring Using Depth Sensing Cameras: A Review of Current Literature |
title_sort | noncontact respiratory monitoring using depth sensing cameras a review of current literature |
topic | noncontact monitoring depth-sensing camera respiratory monitoring respiratory rate tidal volume respiratory patterns |
url | https://www.mdpi.com/1424-8220/21/4/1135 |
work_keys_str_mv | AT anthonypaddison noncontactrespiratorymonitoringusingdepthsensingcamerasareviewofcurrentliterature AT paulsaddison noncontactrespiratorymonitoringusingdepthsensingcamerasareviewofcurrentliterature AT philipsmit noncontactrespiratorymonitoringusingdepthsensingcamerasareviewofcurrentliterature AT dominiquejacquel noncontactrespiratorymonitoringusingdepthsensingcamerasareviewofcurrentliterature AT ulfrborg noncontactrespiratorymonitoringusingdepthsensingcamerasareviewofcurrentliterature |