Use of transesophageal echocardiography during implantation of aortic endoprosthesis (stent). Initial experience

OBJECTIVE: To report the role played by transesophageal echocardiography during implantation of self-expanding aortic endoprostheses (stent) at a hemodynamics laboratory. METHODS: Thirteen patients underwent stent implantation in the descending thoracic aorta with the aid of transesophageal echocard...

Full description

Bibliographic Details
Main Authors: Cláudio Henrique Fischer, Orlando Campos Fº, José Honório de Almeida Palma da Fonseca, Cláudia Maria Rodrigues Alves, José Augusto Marcondes Sousa, Edgar Bezerra de Lira Fº, Antonio Carlos de Camargo Carvalho, Ângelo Amato Vicenzo de Paola, Ênio Buffolo
Format: Article
Language:English
Published: Sociedade Brasileira de Cardiologia (SBC) 2001-07-01
Series:Arquivos Brasileiros de Cardiologia
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2001000700001
_version_ 1818901697325432832
author Cláudio Henrique Fischer
Orlando Campos Fº
José Honório de Almeida Palma da Fonseca
Cláudia Maria Rodrigues Alves
José Augusto Marcondes Sousa
Edgar Bezerra de Lira Fº
Antonio Carlos de Camargo Carvalho
Ângelo Amato Vicenzo de Paola
Ênio Buffolo
author_facet Cláudio Henrique Fischer
Orlando Campos Fº
José Honório de Almeida Palma da Fonseca
Cláudia Maria Rodrigues Alves
José Augusto Marcondes Sousa
Edgar Bezerra de Lira Fº
Antonio Carlos de Camargo Carvalho
Ângelo Amato Vicenzo de Paola
Ênio Buffolo
author_sort Cláudio Henrique Fischer
collection DOAJ
description OBJECTIVE: To report the role played by transesophageal echocardiography during implantation of self-expanding aortic endoprostheses (stent) at a hemodynamics laboratory. METHODS: Thirteen patients underwent stent implantation in the descending thoracic aorta with the aid of transesophageal echocardiography during the entire procedure. Indications for stenting were as follows: 8 aortic dissections, 2 true aneurysms, 2 penetrating atherosclerotic ulcers, and 1 traumatic pseudoaneurysm. RESULTS: No complications resulting from the use of transesophageal echocardiography were observed. In 12 patients, the initial result was considered appropriate, with total or partial resolution of the major lesion confirmed by a posterior examination. In 1 patient, the procedure was suspended after transesophageal echocardiography and angiography showed that the proximal aortic diameter was inappropriate. Transesophageal echocardiography contributed to clarifying relevant points, such as aortic diameter, anatomic detail of the intimal lesion, and location and size of the communicating orifice. In addition, it facilitated placing the stent in the target lesion, reduced the time of exposure to radiation and the use of contrast medium, and provided rapid identification of intercurrent events, possibly reducing the total duration of the procedure. CONCLUSION: The use of transesophageal echocardiography during placement of aortic stents seems appropriate. The actual advantages of the procedure will be defined in a comparative prospective study.
first_indexed 2024-12-19T20:23:52Z
format Article
id doaj.art-afe03a5d37134db5a9e3f67d42392403
institution Directory Open Access Journal
issn 0066-782X
1678-4170
language English
last_indexed 2024-12-19T20:23:52Z
publishDate 2001-07-01
publisher Sociedade Brasileira de Cardiologia (SBC)
record_format Article
series Arquivos Brasileiros de Cardiologia
spelling doaj.art-afe03a5d37134db5a9e3f67d423924032022-12-21T20:06:53ZengSociedade Brasileira de Cardiologia (SBC)Arquivos Brasileiros de Cardiologia0066-782X1678-41702001-07-01771050810.1590/S0066-782X2001000700001Use of transesophageal echocardiography during implantation of aortic endoprosthesis (stent). Initial experienceCláudio Henrique FischerOrlando Campos FºJosé Honório de Almeida Palma da FonsecaCláudia Maria Rodrigues AlvesJosé Augusto Marcondes SousaEdgar Bezerra de Lira FºAntonio Carlos de Camargo CarvalhoÂngelo Amato Vicenzo de PaolaÊnio BuffoloOBJECTIVE: To report the role played by transesophageal echocardiography during implantation of self-expanding aortic endoprostheses (stent) at a hemodynamics laboratory. METHODS: Thirteen patients underwent stent implantation in the descending thoracic aorta with the aid of transesophageal echocardiography during the entire procedure. Indications for stenting were as follows: 8 aortic dissections, 2 true aneurysms, 2 penetrating atherosclerotic ulcers, and 1 traumatic pseudoaneurysm. RESULTS: No complications resulting from the use of transesophageal echocardiography were observed. In 12 patients, the initial result was considered appropriate, with total or partial resolution of the major lesion confirmed by a posterior examination. In 1 patient, the procedure was suspended after transesophageal echocardiography and angiography showed that the proximal aortic diameter was inappropriate. Transesophageal echocardiography contributed to clarifying relevant points, such as aortic diameter, anatomic detail of the intimal lesion, and location and size of the communicating orifice. In addition, it facilitated placing the stent in the target lesion, reduced the time of exposure to radiation and the use of contrast medium, and provided rapid identification of intercurrent events, possibly reducing the total duration of the procedure. CONCLUSION: The use of transesophageal echocardiography during placement of aortic stents seems appropriate. The actual advantages of the procedure will be defined in a comparative prospective study.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2001000700001transesophageal echocardiographystentsaortopathies
spellingShingle Cláudio Henrique Fischer
Orlando Campos Fº
José Honório de Almeida Palma da Fonseca
Cláudia Maria Rodrigues Alves
José Augusto Marcondes Sousa
Edgar Bezerra de Lira Fº
Antonio Carlos de Camargo Carvalho
Ângelo Amato Vicenzo de Paola
Ênio Buffolo
Use of transesophageal echocardiography during implantation of aortic endoprosthesis (stent). Initial experience
Arquivos Brasileiros de Cardiologia
transesophageal echocardiography
stents
aortopathies
title Use of transesophageal echocardiography during implantation of aortic endoprosthesis (stent). Initial experience
title_full Use of transesophageal echocardiography during implantation of aortic endoprosthesis (stent). Initial experience
title_fullStr Use of transesophageal echocardiography during implantation of aortic endoprosthesis (stent). Initial experience
title_full_unstemmed Use of transesophageal echocardiography during implantation of aortic endoprosthesis (stent). Initial experience
title_short Use of transesophageal echocardiography during implantation of aortic endoprosthesis (stent). Initial experience
title_sort use of transesophageal echocardiography during implantation of aortic endoprosthesis stent initial experience
topic transesophageal echocardiography
stents
aortopathies
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2001000700001
work_keys_str_mv AT claudiohenriquefischer useoftransesophagealechocardiographyduringimplantationofaorticendoprosthesisstentinitialexperience
AT orlandocamposfo useoftransesophagealechocardiographyduringimplantationofaorticendoprosthesisstentinitialexperience
AT josehonoriodealmeidapalmadafonseca useoftransesophagealechocardiographyduringimplantationofaorticendoprosthesisstentinitialexperience
AT claudiamariarodriguesalves useoftransesophagealechocardiographyduringimplantationofaorticendoprosthesisstentinitialexperience
AT joseaugustomarcondessousa useoftransesophagealechocardiographyduringimplantationofaorticendoprosthesisstentinitialexperience
AT edgarbezerradelirafo useoftransesophagealechocardiographyduringimplantationofaorticendoprosthesisstentinitialexperience
AT antoniocarlosdecamargocarvalho useoftransesophagealechocardiographyduringimplantationofaorticendoprosthesisstentinitialexperience
AT angeloamatovicenzodepaola useoftransesophagealechocardiographyduringimplantationofaorticendoprosthesisstentinitialexperience
AT eniobuffolo useoftransesophagealechocardiographyduringimplantationofaorticendoprosthesisstentinitialexperience