Calculated left ventricular outflow tract diameter for critically ill patients
Abstract A fast and reliable left ventricular outflow diameter (LVOTd) estimation may aid in quickly estimating cardiac output. However, obtaining a correct LVOTd can be difficult in intensive care patients, potentially leading to errors and a cardiac output deviation. In this study, the measured LV...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
BMC
2022-06-01
|
Series: | Journal of Intensive Care |
Subjects: | |
Online Access: | https://doi.org/10.1186/s40560-022-00623-6 |
_version_ | 1811227235818930176 |
---|---|
author | Eline G. M. Cox Jacqueline Koeze Iwan C. C. van der Horst Renske Wiersema |
author_facet | Eline G. M. Cox Jacqueline Koeze Iwan C. C. van der Horst Renske Wiersema |
author_sort | Eline G. M. Cox |
collection | DOAJ |
description | Abstract A fast and reliable left ventricular outflow diameter (LVOTd) estimation may aid in quickly estimating cardiac output. However, obtaining a correct LVOTd can be difficult in intensive care patients, potentially leading to errors and a cardiac output deviation. In this study, the measured LVOTd was compared with the expected LVOTd when estimated using an existing formula in 1177 critically ill patients. We show that estimated LVOTd based on baseline data can aid when obtaining LVOTd is difficult or impossible and simplified estimation based on a formula may allow for more reliable and accessible measurement of cardiac output. |
first_indexed | 2024-04-12T09:38:05Z |
format | Article |
id | doaj.art-aff64d55d1774e67aa7669bdb2f5e9cc |
institution | Directory Open Access Journal |
issn | 2052-0492 |
language | English |
last_indexed | 2024-04-12T09:38:05Z |
publishDate | 2022-06-01 |
publisher | BMC |
record_format | Article |
series | Journal of Intensive Care |
spelling | doaj.art-aff64d55d1774e67aa7669bdb2f5e9cc2022-12-22T03:38:10ZengBMCJournal of Intensive Care2052-04922022-06-011011310.1186/s40560-022-00623-6Calculated left ventricular outflow tract diameter for critically ill patientsEline G. M. Cox0Jacqueline Koeze1Iwan C. C. van der Horst2Renske Wiersema3Department of Critical Care, University of Groningen, University Medical Center GroningenDepartment of Critical Care, University of Groningen, University Medical Center GroningenDepartment of Intensive Care Medicine, Maastricht University, Maastricht University Medical Centre+ MaastrichtDepartment of Critical Care, University of Groningen, University Medical Center GroningenAbstract A fast and reliable left ventricular outflow diameter (LVOTd) estimation may aid in quickly estimating cardiac output. However, obtaining a correct LVOTd can be difficult in intensive care patients, potentially leading to errors and a cardiac output deviation. In this study, the measured LVOTd was compared with the expected LVOTd when estimated using an existing formula in 1177 critically ill patients. We show that estimated LVOTd based on baseline data can aid when obtaining LVOTd is difficult or impossible and simplified estimation based on a formula may allow for more reliable and accessible measurement of cardiac output.https://doi.org/10.1186/s40560-022-00623-6Prospective studyCritical care ultrasoundCardiac outputLeft ventricular outflow tractCritical careIntensive care unit |
spellingShingle | Eline G. M. Cox Jacqueline Koeze Iwan C. C. van der Horst Renske Wiersema Calculated left ventricular outflow tract diameter for critically ill patients Journal of Intensive Care Prospective study Critical care ultrasound Cardiac output Left ventricular outflow tract Critical care Intensive care unit |
title | Calculated left ventricular outflow tract diameter for critically ill patients |
title_full | Calculated left ventricular outflow tract diameter for critically ill patients |
title_fullStr | Calculated left ventricular outflow tract diameter for critically ill patients |
title_full_unstemmed | Calculated left ventricular outflow tract diameter for critically ill patients |
title_short | Calculated left ventricular outflow tract diameter for critically ill patients |
title_sort | calculated left ventricular outflow tract diameter for critically ill patients |
topic | Prospective study Critical care ultrasound Cardiac output Left ventricular outflow tract Critical care Intensive care unit |
url | https://doi.org/10.1186/s40560-022-00623-6 |
work_keys_str_mv | AT elinegmcox calculatedleftventricularoutflowtractdiameterforcriticallyillpatients AT jacquelinekoeze calculatedleftventricularoutflowtractdiameterforcriticallyillpatients AT iwanccvanderhorst calculatedleftventricularoutflowtractdiameterforcriticallyillpatients AT renskewiersema calculatedleftventricularoutflowtractdiameterforcriticallyillpatients |