The Influence of Adaptive Statistical Iterative Reconstruction Algorithm on Image Quality and Volume CT Dose Index in Head CT Scan Compared To Filtered Back Projection
Introduction: This study aimed to compare the image quality and volume dose index of head CT scan between two adaptive statistical iterative reconstructions (ASIR) and the filtered back projection (FBP) algorithms.Material and Methods: CT number, noise and signal to noise ratio(SNR) for white matter...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Mashhad University of Medical Sciences
2023-11-01
|
Series: | Iranian Journal of Medical Physics |
Subjects: | |
Online Access: | https://ijmp.mums.ac.ir/article_22065_78f465edb9c6b530076fad01a84b4464.pdf |
_version_ | 1797209642290380800 |
---|---|
author | Sahand Barzanjeh Salman Jafari Kamaledin Hadei Karim Ghazikhanlou sani |
author_facet | Sahand Barzanjeh Salman Jafari Kamaledin Hadei Karim Ghazikhanlou sani |
author_sort | Sahand Barzanjeh |
collection | DOAJ |
description | Introduction: This study aimed to compare the image quality and volume dose index of head CT scan between two adaptive statistical iterative reconstructions (ASIR) and the filtered back projection (FBP) algorithms.Material and Methods: CT number, noise and signal to noise ratio(SNR) for white matter(WM), gray matter(WM), cerebrospinal fluid(CSF( and skull bone were investigated in brain CT scans of 60 patients. All images were reconstructed by FBP and ASIR 40% algorithms. A water phantom was also used to compare the average CT number; noise, signal-to-noise (SNR), and contrast-to-noise ratio (CNR) between algorithms under different acquisition parameters. Volume computed tomography dose index (CTDIvol) and (dose-length product) DLP were obtained from scanner software. Data were analyzed by T-test and Mann-Whitney statistical test with a significance level of less than 0.05.Results: Image noise of gray matter, CSF and skull bone was significantly lower for ASIR algorithm (P<0.05). The difference in SNR for white matter and gray matter was not significant between the two algorithms but it was higher for CSF and bone for ASIR. In phantom study, Image noise, CTDIvol and DLP in both axial and spiral scan modes were higher for FBP algorithm (P<0.05). In addition, there was no significant difference in SNR and CNR between the two algorithms (P>0.05).Conclusion: ASIR algorithm reduces the dose and image noise in head CT scan compared to the filtered back projection. In addition, using ASIR algorithm the image noise does not increase with lower mA. |
first_indexed | 2024-04-24T09:57:57Z |
format | Article |
id | doaj.art-b08aa4f47ef342ea830de6cf0b99db08 |
institution | Directory Open Access Journal |
issn | 2345-3672 |
language | English |
last_indexed | 2024-04-24T09:57:57Z |
publishDate | 2023-11-01 |
publisher | Mashhad University of Medical Sciences |
record_format | Article |
series | Iranian Journal of Medical Physics |
spelling | doaj.art-b08aa4f47ef342ea830de6cf0b99db082024-04-14T06:28:25ZengMashhad University of Medical SciencesIranian Journal of Medical Physics2345-36722023-11-0120632833210.22038/ijmp.2023.70261.223722065The Influence of Adaptive Statistical Iterative Reconstruction Algorithm on Image Quality and Volume CT Dose Index in Head CT Scan Compared To Filtered Back ProjectionSahand Barzanjeh0Salman Jafari1Kamaledin Hadei2Karim Ghazikhanlou sani3School of Medicine, Hamadan University of Medical Sciences, Hamadan, IranDepartment of Radiology Technology, School of Paramedicine, Hamadan University of Medical Sciences, Hamadan, IranDepartment of Radiology, School of Medicine, Hamadan University of Medical Sciences, Hamadan, IranDepartment of Radiology Technology, School of Paramedicine, Hamadan University of Medical Sciences, Hamadan, IranIntroduction: This study aimed to compare the image quality and volume dose index of head CT scan between two adaptive statistical iterative reconstructions (ASIR) and the filtered back projection (FBP) algorithms.Material and Methods: CT number, noise and signal to noise ratio(SNR) for white matter(WM), gray matter(WM), cerebrospinal fluid(CSF( and skull bone were investigated in brain CT scans of 60 patients. All images were reconstructed by FBP and ASIR 40% algorithms. A water phantom was also used to compare the average CT number; noise, signal-to-noise (SNR), and contrast-to-noise ratio (CNR) between algorithms under different acquisition parameters. Volume computed tomography dose index (CTDIvol) and (dose-length product) DLP were obtained from scanner software. Data were analyzed by T-test and Mann-Whitney statistical test with a significance level of less than 0.05.Results: Image noise of gray matter, CSF and skull bone was significantly lower for ASIR algorithm (P<0.05). The difference in SNR for white matter and gray matter was not significant between the two algorithms but it was higher for CSF and bone for ASIR. In phantom study, Image noise, CTDIvol and DLP in both axial and spiral scan modes were higher for FBP algorithm (P<0.05). In addition, there was no significant difference in SNR and CNR between the two algorithms (P>0.05).Conclusion: ASIR algorithm reduces the dose and image noise in head CT scan compared to the filtered back projection. In addition, using ASIR algorithm the image noise does not increase with lower mA.https://ijmp.mums.ac.ir/article_22065_78f465edb9c6b530076fad01a84b4464.pdfct scanreconstruction algorithmradiation dosagesimage quality |
spellingShingle | Sahand Barzanjeh Salman Jafari Kamaledin Hadei Karim Ghazikhanlou sani The Influence of Adaptive Statistical Iterative Reconstruction Algorithm on Image Quality and Volume CT Dose Index in Head CT Scan Compared To Filtered Back Projection Iranian Journal of Medical Physics ct scan reconstruction algorithm radiation dosages image quality |
title | The Influence of Adaptive Statistical Iterative Reconstruction Algorithm on Image Quality and Volume CT Dose Index in Head CT Scan Compared To Filtered Back Projection |
title_full | The Influence of Adaptive Statistical Iterative Reconstruction Algorithm on Image Quality and Volume CT Dose Index in Head CT Scan Compared To Filtered Back Projection |
title_fullStr | The Influence of Adaptive Statistical Iterative Reconstruction Algorithm on Image Quality and Volume CT Dose Index in Head CT Scan Compared To Filtered Back Projection |
title_full_unstemmed | The Influence of Adaptive Statistical Iterative Reconstruction Algorithm on Image Quality and Volume CT Dose Index in Head CT Scan Compared To Filtered Back Projection |
title_short | The Influence of Adaptive Statistical Iterative Reconstruction Algorithm on Image Quality and Volume CT Dose Index in Head CT Scan Compared To Filtered Back Projection |
title_sort | influence of adaptive statistical iterative reconstruction algorithm on image quality and volume ct dose index in head ct scan compared to filtered back projection |
topic | ct scan reconstruction algorithm radiation dosages image quality |
url | https://ijmp.mums.ac.ir/article_22065_78f465edb9c6b530076fad01a84b4464.pdf |
work_keys_str_mv | AT sahandbarzanjeh theinfluenceofadaptivestatisticaliterativereconstructionalgorithmonimagequalityandvolumectdoseindexinheadctscancomparedtofilteredbackprojection AT salmanjafari theinfluenceofadaptivestatisticaliterativereconstructionalgorithmonimagequalityandvolumectdoseindexinheadctscancomparedtofilteredbackprojection AT kamaledinhadei theinfluenceofadaptivestatisticaliterativereconstructionalgorithmonimagequalityandvolumectdoseindexinheadctscancomparedtofilteredbackprojection AT karimghazikhanlousani theinfluenceofadaptivestatisticaliterativereconstructionalgorithmonimagequalityandvolumectdoseindexinheadctscancomparedtofilteredbackprojection AT sahandbarzanjeh influenceofadaptivestatisticaliterativereconstructionalgorithmonimagequalityandvolumectdoseindexinheadctscancomparedtofilteredbackprojection AT salmanjafari influenceofadaptivestatisticaliterativereconstructionalgorithmonimagequalityandvolumectdoseindexinheadctscancomparedtofilteredbackprojection AT kamaledinhadei influenceofadaptivestatisticaliterativereconstructionalgorithmonimagequalityandvolumectdoseindexinheadctscancomparedtofilteredbackprojection AT karimghazikhanlousani influenceofadaptivestatisticaliterativereconstructionalgorithmonimagequalityandvolumectdoseindexinheadctscancomparedtofilteredbackprojection |