Rain Intrusion through Horizontal Joints in Façade Panel Systems—Experimental Investigation

Façade panel systems with horizontal open joints are commonly used on larger buildings in Nordic countries. Excessive water intrusion through open joints may cause deterioration of the façade, a concern exacerbated by climate change. Previous studies have shown that current design recommendations fo...

Full description

Bibliographic Details
Main Authors: Eva Armstrong Støver, Marte Haugen Sundsøy, Erlend Andenæs, Stig Geving, Tore Kvande
Format: Article
Language:English
Published: MDPI AG 2022-09-01
Series:Buildings
Subjects:
Online Access:https://www.mdpi.com/2075-5309/12/10/1497
_version_ 1797474726865534976
author Eva Armstrong Støver
Marte Haugen Sundsøy
Erlend Andenæs
Stig Geving
Tore Kvande
author_facet Eva Armstrong Støver
Marte Haugen Sundsøy
Erlend Andenæs
Stig Geving
Tore Kvande
author_sort Eva Armstrong Støver
collection DOAJ
description Façade panel systems with horizontal open joints are commonly used on larger buildings in Nordic countries. Excessive water intrusion through open joints may cause deterioration of the façade, a concern exacerbated by climate change. Previous studies have shown that current design recommendations for open-joint façade panel systems may not be optimal to prevent water intrusion. It is therefore of interest to investigate the watertightness of different design solutions for horizontal joints to inform recommendations for more durable façades. Large-scale measurements are conducted in a driving rain apparatus. Façade panel systems with different joint solutions are tested according to NS-EN 1027:2016. In total, 72 unique tests are conducted, investigating the impact of the four parameters: panel types, joint widths, joint profiles, and bevelled joint designs. All designs performed differently for the different types of panels, making it difficult to draw general conclusions. Smooth panels consistently exhibit higher water intrusion rates than rough panels, because runoff concentrates in streams on a smooth surface, causing localized, great intrusion in the horizontal joints. Modifications of the joints or the insertion of aluminium profiles may reduce or increase water intrusion. The most watertight among the investigated solutions involves an h-shaped profile. Bevelled joints improve overall watertightness but may direct more water towards the wind barrier. For open joints, a narrower joint width was found to decrease water intrusion to the wind barrier. In general, a barrier is needed to protect the joints against water intrusion. However, the effectiveness of protection measures depends on their design and mounting. Some protection measures led to greater water intrusion than no barrier at all.
first_indexed 2024-03-09T20:34:18Z
format Article
id doaj.art-b1120fd43b474f44b33945d5d0d9d455
institution Directory Open Access Journal
issn 2075-5309
language English
last_indexed 2024-03-09T20:34:18Z
publishDate 2022-09-01
publisher MDPI AG
record_format Article
series Buildings
spelling doaj.art-b1120fd43b474f44b33945d5d0d9d4552023-11-23T23:15:15ZengMDPI AGBuildings2075-53092022-09-011210149710.3390/buildings12101497Rain Intrusion through Horizontal Joints in Façade Panel Systems—Experimental InvestigationEva Armstrong Støver0Marte Haugen Sundsøy1Erlend Andenæs2Stig Geving3Tore Kvande4Department of Civil and Environmental Engineering, Norwegian University of Science and Technology (NTNU), 7491 Trondheim, NorwayDepartment of Civil and Environmental Engineering, Norwegian University of Science and Technology (NTNU), 7491 Trondheim, NorwayDepartment of Civil and Environmental Engineering, Norwegian University of Science and Technology (NTNU), 7491 Trondheim, NorwayDepartment of Architecture, Materials and Structures, SINTEF Community, 7465 Trondheim, NorwayDepartment of Civil and Environmental Engineering, Norwegian University of Science and Technology (NTNU), 7491 Trondheim, NorwayFaçade panel systems with horizontal open joints are commonly used on larger buildings in Nordic countries. Excessive water intrusion through open joints may cause deterioration of the façade, a concern exacerbated by climate change. Previous studies have shown that current design recommendations for open-joint façade panel systems may not be optimal to prevent water intrusion. It is therefore of interest to investigate the watertightness of different design solutions for horizontal joints to inform recommendations for more durable façades. Large-scale measurements are conducted in a driving rain apparatus. Façade panel systems with different joint solutions are tested according to NS-EN 1027:2016. In total, 72 unique tests are conducted, investigating the impact of the four parameters: panel types, joint widths, joint profiles, and bevelled joint designs. All designs performed differently for the different types of panels, making it difficult to draw general conclusions. Smooth panels consistently exhibit higher water intrusion rates than rough panels, because runoff concentrates in streams on a smooth surface, causing localized, great intrusion in the horizontal joints. Modifications of the joints or the insertion of aluminium profiles may reduce or increase water intrusion. The most watertight among the investigated solutions involves an h-shaped profile. Bevelled joints improve overall watertightness but may direct more water towards the wind barrier. For open joints, a narrower joint width was found to decrease water intrusion to the wind barrier. In general, a barrier is needed to protect the joints against water intrusion. However, the effectiveness of protection measures depends on their design and mounting. Some protection measures led to greater water intrusion than no barrier at all.https://www.mdpi.com/2075-5309/12/10/1497water intrusionrain intrusionopen jointlaboratory measurementsfaçade panel systemswatertightness
spellingShingle Eva Armstrong Støver
Marte Haugen Sundsøy
Erlend Andenæs
Stig Geving
Tore Kvande
Rain Intrusion through Horizontal Joints in Façade Panel Systems—Experimental Investigation
Buildings
water intrusion
rain intrusion
open joint
laboratory measurements
façade panel systems
watertightness
title Rain Intrusion through Horizontal Joints in Façade Panel Systems—Experimental Investigation
title_full Rain Intrusion through Horizontal Joints in Façade Panel Systems—Experimental Investigation
title_fullStr Rain Intrusion through Horizontal Joints in Façade Panel Systems—Experimental Investigation
title_full_unstemmed Rain Intrusion through Horizontal Joints in Façade Panel Systems—Experimental Investigation
title_short Rain Intrusion through Horizontal Joints in Façade Panel Systems—Experimental Investigation
title_sort rain intrusion through horizontal joints in facade panel systems experimental investigation
topic water intrusion
rain intrusion
open joint
laboratory measurements
façade panel systems
watertightness
url https://www.mdpi.com/2075-5309/12/10/1497
work_keys_str_mv AT evaarmstrongstøver rainintrusionthroughhorizontaljointsinfacadepanelsystemsexperimentalinvestigation
AT martehaugensundsøy rainintrusionthroughhorizontaljointsinfacadepanelsystemsexperimentalinvestigation
AT erlendandenæs rainintrusionthroughhorizontaljointsinfacadepanelsystemsexperimentalinvestigation
AT stiggeving rainintrusionthroughhorizontaljointsinfacadepanelsystemsexperimentalinvestigation
AT torekvande rainintrusionthroughhorizontaljointsinfacadepanelsystemsexperimentalinvestigation