Comparison of tracheal tube cuff pressure with two techniques: fixed volume versus pilot balloon palpation
Introduction: Filling tracheal tube cuff (TTC) after intubation is necessary to provide a safe airway in intubated patients. On the other hand, excessive increase or decrease in the pressure of TTC’s balloon leads into the dangerous complications such as necrosis and/or aspiration. Accordingly, in t...
Main Authors: | , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Tabriz University of Medical Sciences
2017-12-01
|
Series: | Journal of Cardiovascular and Thoracic Research |
Subjects: | |
Online Access: | https://jcvtr.tbzmed.ac.ir/PDF/jcvtr-9-169.pdf |
_version_ | 1819106431984467968 |
---|---|
author | Farzad Rahmani Hassan Soleimanpour Ali Zeynali Ata Mahmoodpoor Kavous Shahsavari Nia Jafar Rahimi Panahi Sarvin Sanaei Maryam Soleimanpour Robab Mehdizadeh Esfanjani |
author_facet | Farzad Rahmani Hassan Soleimanpour Ali Zeynali Ata Mahmoodpoor Kavous Shahsavari Nia Jafar Rahimi Panahi Sarvin Sanaei Maryam Soleimanpour Robab Mehdizadeh Esfanjani |
author_sort | Farzad Rahmani |
collection | DOAJ |
description | Introduction: Filling tracheal tube cuff (TTC) after intubation is necessary to provide a safe airway in intubated patients. On the other hand, excessive increase or decrease in the pressure of TTC’s balloon leads into the dangerous complications such as necrosis and/or aspiration. Accordingly, in the present study, we tried to evaluate the most two common fixed volume and pilot balloon palpitation methods to control TTC pressure. Methods: In a prospective cross-sectional study that was carried out in the emergency department of Tabriz Imam Reza hospital upon 194 patients who needed intubation and from April 2015 to June 2016. The patients were randomly allocated into two equal groups. For the first the Pilot Balloon Palpation technique and for the second group 10 cc fixed volume cuff filling technique was assigned. After that, the pressure was checked with manometer and data were analyzed using SPSS software. Results: TTC pressure average in fixed volume group was 44.96±21.77 cmH2O and for palpation group, it was 118.15±22.15 cmH2O. There was a meaningful difference between two groups in terms of cuff inside pressure (P value <0.001) and it was meaningfully lower in fixed volume group than the first one. Conclusion: The present study showed that pilot balloon palpation or fixed volume method was not appropriate methods to assess cuff pressure during intubation and the cuff pressure must be controlled by the manometer. |
first_indexed | 2024-12-22T02:38:02Z |
format | Article |
id | doaj.art-b153d99fe5cb430da7db17bf8fffa652 |
institution | Directory Open Access Journal |
issn | 2008-5117 2008-6830 |
language | English |
last_indexed | 2024-12-22T02:38:02Z |
publishDate | 2017-12-01 |
publisher | Tabriz University of Medical Sciences |
record_format | Article |
series | Journal of Cardiovascular and Thoracic Research |
spelling | doaj.art-b153d99fe5cb430da7db17bf8fffa6522022-12-21T18:41:42ZengTabriz University of Medical SciencesJournal of Cardiovascular and Thoracic Research2008-51172008-68302017-12-019419619910.15171/jcvtr.2017.34JCVTR_4159_20170501192853Comparison of tracheal tube cuff pressure with two techniques: fixed volume versus pilot balloon palpationFarzad Rahmani0Hassan Soleimanpour1Ali Zeynali2Ata Mahmoodpoor3Kavous Shahsavari Nia4Jafar Rahimi Panahi5Sarvin Sanaei6Maryam Soleimanpour7Robab Mehdizadeh Esfanjani8Road Traffic Injury Research Center, Tabriz University of Medical Sciences, Tabriz, IranRoad Traffic Injury Research Center, Tabriz University of Medical Sciences, Tabriz, IranStudents’ Research Committee, Tabriz University of Medical Sciences, Tabriz, IranAnesthesiology Research Team, Department of Anesthesiology, Tabriz University of Medical Sciences, Tabriz, IranEmergency Medicine Research Team, Tabriz University of Medical Sciences, Tabriz, IranAnesthesiology Research Team, Department of Anesthesiology, Tabriz University of Medical Sciences, Tabriz, IranTuberculosis and Lung Research Center, Tabriz University of Medical Sciences, Tabriz, IranSocial Determinants of Health Research Center, Tabriz University of Medical Sciences, Tabriz, IranNeurosciences Research Center, Tabriz University of Medical Sciences, Tabriz, IranIntroduction: Filling tracheal tube cuff (TTC) after intubation is necessary to provide a safe airway in intubated patients. On the other hand, excessive increase or decrease in the pressure of TTC’s balloon leads into the dangerous complications such as necrosis and/or aspiration. Accordingly, in the present study, we tried to evaluate the most two common fixed volume and pilot balloon palpitation methods to control TTC pressure. Methods: In a prospective cross-sectional study that was carried out in the emergency department of Tabriz Imam Reza hospital upon 194 patients who needed intubation and from April 2015 to June 2016. The patients were randomly allocated into two equal groups. For the first the Pilot Balloon Palpation technique and for the second group 10 cc fixed volume cuff filling technique was assigned. After that, the pressure was checked with manometer and data were analyzed using SPSS software. Results: TTC pressure average in fixed volume group was 44.96±21.77 cmH2O and for palpation group, it was 118.15±22.15 cmH2O. There was a meaningful difference between two groups in terms of cuff inside pressure (P value <0.001) and it was meaningfully lower in fixed volume group than the first one. Conclusion: The present study showed that pilot balloon palpation or fixed volume method was not appropriate methods to assess cuff pressure during intubation and the cuff pressure must be controlled by the manometer.https://jcvtr.tbzmed.ac.ir/PDF/jcvtr-9-169.pdfendotracheal intubationtracheal tube cuff pressureemergency department |
spellingShingle | Farzad Rahmani Hassan Soleimanpour Ali Zeynali Ata Mahmoodpoor Kavous Shahsavari Nia Jafar Rahimi Panahi Sarvin Sanaei Maryam Soleimanpour Robab Mehdizadeh Esfanjani Comparison of tracheal tube cuff pressure with two techniques: fixed volume versus pilot balloon palpation Journal of Cardiovascular and Thoracic Research endotracheal intubation tracheal tube cuff pressure emergency department |
title | Comparison of tracheal tube cuff pressure with two techniques: fixed volume versus pilot balloon palpation |
title_full | Comparison of tracheal tube cuff pressure with two techniques: fixed volume versus pilot balloon palpation |
title_fullStr | Comparison of tracheal tube cuff pressure with two techniques: fixed volume versus pilot balloon palpation |
title_full_unstemmed | Comparison of tracheal tube cuff pressure with two techniques: fixed volume versus pilot balloon palpation |
title_short | Comparison of tracheal tube cuff pressure with two techniques: fixed volume versus pilot balloon palpation |
title_sort | comparison of tracheal tube cuff pressure with two techniques fixed volume versus pilot balloon palpation |
topic | endotracheal intubation tracheal tube cuff pressure emergency department |
url | https://jcvtr.tbzmed.ac.ir/PDF/jcvtr-9-169.pdf |
work_keys_str_mv | AT farzadrahmani comparisonoftrachealtubecuffpressurewithtwotechniquesfixedvolumeversuspilotballoonpalpation AT hassansoleimanpour comparisonoftrachealtubecuffpressurewithtwotechniquesfixedvolumeversuspilotballoonpalpation AT alizeynali comparisonoftrachealtubecuffpressurewithtwotechniquesfixedvolumeversuspilotballoonpalpation AT atamahmoodpoor comparisonoftrachealtubecuffpressurewithtwotechniquesfixedvolumeversuspilotballoonpalpation AT kavousshahsavarinia comparisonoftrachealtubecuffpressurewithtwotechniquesfixedvolumeversuspilotballoonpalpation AT jafarrahimipanahi comparisonoftrachealtubecuffpressurewithtwotechniquesfixedvolumeversuspilotballoonpalpation AT sarvinsanaei comparisonoftrachealtubecuffpressurewithtwotechniquesfixedvolumeversuspilotballoonpalpation AT maryamsoleimanpour comparisonoftrachealtubecuffpressurewithtwotechniquesfixedvolumeversuspilotballoonpalpation AT robabmehdizadehesfanjani comparisonoftrachealtubecuffpressurewithtwotechniquesfixedvolumeversuspilotballoonpalpation |