Accuracy of the ankle-brachial index using the SCVL®, an arm and ankle automated device with synchronized cuffs, in a population with increased cardiovascular risk

David Rosenbaum1,2, Sandra Rodriguez-Carranza1,3, Patrick Laroche4, Eric Bruckert1,2, Philippe Giral1,2, Xavier Girerd1,21Unité de Prévention Cardiovasculaire, Service d'Endocrinologie-Métabolisme, Assistance Publique/Hôpitaux de...

Full description

Bibliographic Details
Main Authors: Rosenbaum D, Rodriguez-Carranza S, Laroche P, Bruckert E, Giral P, Girerd X
Format: Article
Language:English
Published: Dove Medical Press 2012-04-01
Series:Vascular Health and Risk Management
Online Access:http://www.dovepress.com/accuracy-of-the-ankle-brachial-index-using-the-scvlreg-an-arm-and-ankl-a9717
_version_ 1818231687455178752
author Rosenbaum D
Rodriguez-Carranza S
Laroche P
Bruckert E
Giral P
Girerd X
author_facet Rosenbaum D
Rodriguez-Carranza S
Laroche P
Bruckert E
Giral P
Girerd X
author_sort Rosenbaum D
collection DOAJ
description David Rosenbaum1,2, Sandra Rodriguez-Carranza1,3, Patrick Laroche4, Eric Bruckert1,2, Philippe Giral1,2, Xavier Girerd1,21Unité de Prévention Cardiovasculaire, Service d'Endocrinologie-Métabolisme, Assistance Publique/Hôpitaux de Paris, Groupe Hospitalier Pitié-Salpêtrière – Université Pierre et Marie Curie, 2Dyslipoproteinemia and Atherosclerosis Research Unit, National Institute for Health and Medical Research (INSERM) and Pierre et Marie Curie University (UPMC – Paris VI), Paris, France; 3Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán Departamento de Endocrinología y Metabolismo, Delegación Tlalpan, México Distrito Federal; 4STACTIS, Paris, FranceObjective: To evaluate the accuracy of the ankle brachial index (ABI) measured with the SCVL® (“screening cardiovascular lab”; GenNov, Paris, France), an automated device with synchronized arm and ankle cuffs with an automatic ABI calculation.Methods: Patients were consecutively included in a cardiovascular prevention unit if they presented with at least two cardiovascular risk factors. ABI measurements were made using the SCVL, following a synchronized assessment of brachial and ankle systolic pressure. These values were compared to the ABI obtained with the usual Doppler-assisted method.Results: We included 157 patients. Mean age was 59.1 years, 56.8% had hypertension, 22.3% had diabetes mellitus, and 17.6% were current smokers. An abnormal ABI was observed in 17.2% with the SCVL and in 16.2% with the Doppler. The prevalence rates of an abnormal ABI by patient measured with each device, ie, 15.7% (confidence interval [CI] 0.95: [11.8; 20.4]) or 14.3% (CI 0.95: [10.7; 18.9]), did not differ. The coefficient of variation of Doppler and SCVL measures was 15.8% and 15.1%, respectively. The regression line between the two measurement methods was statistically significant. The value-to-value comparison also shows a difference of mean equal to 0.010 (CI 0.95: [–0.272; 0.291]) (r = –0.055). Reproducibility of ABI measurements with the SCVL showed a difference of mean equal to 0.009 (CI 0.95: [–0.203; 0.222]), without heteroscedasticity (r = –0.003). Conclusion: The SCVL is a fast and easy to use automated oscillometric device for the determination of ABI. The use of this two-synchronized-cuff device correlates well with the gold standard Doppler ultrasound method and is reproducible. The SCVL may ease the screening for peripheral arterial disease in routine medical practice.Keywords: ankle brachial index, automated device, peripheral arterial disease screening
first_indexed 2024-12-12T10:54:21Z
format Article
id doaj.art-b1ada4284c5448d7a525a1a7f4c5ba17
institution Directory Open Access Journal
issn 1176-6344
1178-2048
language English
last_indexed 2024-12-12T10:54:21Z
publishDate 2012-04-01
publisher Dove Medical Press
record_format Article
series Vascular Health and Risk Management
spelling doaj.art-b1ada4284c5448d7a525a1a7f4c5ba172022-12-22T00:26:41ZengDove Medical PressVascular Health and Risk Management1176-63441178-20482012-04-012012default239246Accuracy of the ankle-brachial index using the SCVL®, an arm and ankle automated device with synchronized cuffs, in a population with increased cardiovascular riskRosenbaum DRodriguez-Carranza SLaroche PBruckert EGiral PGirerd XDavid Rosenbaum1,2, Sandra Rodriguez-Carranza1,3, Patrick Laroche4, Eric Bruckert1,2, Philippe Giral1,2, Xavier Girerd1,21Unité de Prévention Cardiovasculaire, Service d'Endocrinologie-Métabolisme, Assistance Publique/Hôpitaux de Paris, Groupe Hospitalier Pitié-Salpêtrière – Université Pierre et Marie Curie, 2Dyslipoproteinemia and Atherosclerosis Research Unit, National Institute for Health and Medical Research (INSERM) and Pierre et Marie Curie University (UPMC – Paris VI), Paris, France; 3Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán Departamento de Endocrinología y Metabolismo, Delegación Tlalpan, México Distrito Federal; 4STACTIS, Paris, FranceObjective: To evaluate the accuracy of the ankle brachial index (ABI) measured with the SCVL® (“screening cardiovascular lab”; GenNov, Paris, France), an automated device with synchronized arm and ankle cuffs with an automatic ABI calculation.Methods: Patients were consecutively included in a cardiovascular prevention unit if they presented with at least two cardiovascular risk factors. ABI measurements were made using the SCVL, following a synchronized assessment of brachial and ankle systolic pressure. These values were compared to the ABI obtained with the usual Doppler-assisted method.Results: We included 157 patients. Mean age was 59.1 years, 56.8% had hypertension, 22.3% had diabetes mellitus, and 17.6% were current smokers. An abnormal ABI was observed in 17.2% with the SCVL and in 16.2% with the Doppler. The prevalence rates of an abnormal ABI by patient measured with each device, ie, 15.7% (confidence interval [CI] 0.95: [11.8; 20.4]) or 14.3% (CI 0.95: [10.7; 18.9]), did not differ. The coefficient of variation of Doppler and SCVL measures was 15.8% and 15.1%, respectively. The regression line between the two measurement methods was statistically significant. The value-to-value comparison also shows a difference of mean equal to 0.010 (CI 0.95: [–0.272; 0.291]) (r = –0.055). Reproducibility of ABI measurements with the SCVL showed a difference of mean equal to 0.009 (CI 0.95: [–0.203; 0.222]), without heteroscedasticity (r = –0.003). Conclusion: The SCVL is a fast and easy to use automated oscillometric device for the determination of ABI. The use of this two-synchronized-cuff device correlates well with the gold standard Doppler ultrasound method and is reproducible. The SCVL may ease the screening for peripheral arterial disease in routine medical practice.Keywords: ankle brachial index, automated device, peripheral arterial disease screeninghttp://www.dovepress.com/accuracy-of-the-ankle-brachial-index-using-the-scvlreg-an-arm-and-ankl-a9717
spellingShingle Rosenbaum D
Rodriguez-Carranza S
Laroche P
Bruckert E
Giral P
Girerd X
Accuracy of the ankle-brachial index using the SCVL®, an arm and ankle automated device with synchronized cuffs, in a population with increased cardiovascular risk
Vascular Health and Risk Management
title Accuracy of the ankle-brachial index using the SCVL®, an arm and ankle automated device with synchronized cuffs, in a population with increased cardiovascular risk
title_full Accuracy of the ankle-brachial index using the SCVL®, an arm and ankle automated device with synchronized cuffs, in a population with increased cardiovascular risk
title_fullStr Accuracy of the ankle-brachial index using the SCVL®, an arm and ankle automated device with synchronized cuffs, in a population with increased cardiovascular risk
title_full_unstemmed Accuracy of the ankle-brachial index using the SCVL®, an arm and ankle automated device with synchronized cuffs, in a population with increased cardiovascular risk
title_short Accuracy of the ankle-brachial index using the SCVL®, an arm and ankle automated device with synchronized cuffs, in a population with increased cardiovascular risk
title_sort accuracy of the ankle brachial index using the scvl amp reg an arm and ankle automated device with synchronized cuffs in a population with increased cardiovascular risk
url http://www.dovepress.com/accuracy-of-the-ankle-brachial-index-using-the-scvlreg-an-arm-and-ankl-a9717
work_keys_str_mv AT rosenbaumd accuracyoftheanklebrachialindexusingthescvlampreganarmandankleautomateddevicewithsynchronizedcuffsinapopulationwithincreasedcardiovascularrisk
AT rodriguezcarranzas accuracyoftheanklebrachialindexusingthescvlampreganarmandankleautomateddevicewithsynchronizedcuffsinapopulationwithincreasedcardiovascularrisk
AT larochep accuracyoftheanklebrachialindexusingthescvlampreganarmandankleautomateddevicewithsynchronizedcuffsinapopulationwithincreasedcardiovascularrisk
AT bruckerte accuracyoftheanklebrachialindexusingthescvlampreganarmandankleautomateddevicewithsynchronizedcuffsinapopulationwithincreasedcardiovascularrisk
AT giralp accuracyoftheanklebrachialindexusingthescvlampreganarmandankleautomateddevicewithsynchronizedcuffsinapopulationwithincreasedcardiovascularrisk
AT girerdx accuracyoftheanklebrachialindexusingthescvlampreganarmandankleautomateddevicewithsynchronizedcuffsinapopulationwithincreasedcardiovascularrisk