Islanding Detection with Reduced Non-Detection Zones and Restoration by Reconfiguration
The development and use of PV (Photovoltaic), Wind, and Hydro-based Distributed Generation (DG) is presently on the rise worldwide for improving stability and reliability, and reducing the power loss in the distribution system with reduced emission of harmful gases. A crucial issue addressed in this...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2023-03-01
|
Series: | Energies |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1073/16/7/3035 |
_version_ | 1797608048342073344 |
---|---|
author | Sowmya Ramachandradurai Narayanan Krishnan Gulshan Sharma Pitshou N. Bokoro |
author_facet | Sowmya Ramachandradurai Narayanan Krishnan Gulshan Sharma Pitshou N. Bokoro |
author_sort | Sowmya Ramachandradurai |
collection | DOAJ |
description | The development and use of PV (Photovoltaic), Wind, and Hydro-based Distributed Generation (DG) is presently on the rise worldwide for improving stability and reliability, and reducing the power loss in the distribution system with reduced emission of harmful gases. A crucial issue addressed in this article, due to the increased penetration of DGs, is islanding operations. The detection of islanding is performed by a proposed v&f (voltage and frequency) index method. The reliability indices of the IEEE-33 and 118 radial bus distribution system after the detection of islanding by the proposed method is evaluated by considering the islanding issue as customer interruption. To mitigate the islanding, a reconfiguration strategy using Particle Swarm Optimization (PSO) is also performed and the proposed strategy is also evaluated with the conventional reconfiguration strategy of the distribution system. |
first_indexed | 2024-03-11T05:39:07Z |
format | Article |
id | doaj.art-b22cb6f35255400a93cb1075cc1a9071 |
institution | Directory Open Access Journal |
issn | 1996-1073 |
language | English |
last_indexed | 2024-03-11T05:39:07Z |
publishDate | 2023-03-01 |
publisher | MDPI AG |
record_format | Article |
series | Energies |
spelling | doaj.art-b22cb6f35255400a93cb1075cc1a90712023-11-17T16:36:32ZengMDPI AGEnergies1996-10732023-03-01167303510.3390/en16073035Islanding Detection with Reduced Non-Detection Zones and Restoration by ReconfigurationSowmya Ramachandradurai0Narayanan Krishnan1Gulshan Sharma2Pitshou N. Bokoro3Department of Electrical and Electronics Engineering, Sri Shakthi Institute of Engineering & Technology, Coimbatore 641062, IndiaDepartment of Electrical and Electronics Engineering, SASTRA Deemed to be University, Thanjavur 613401, IndiaDepartment of Electrical Engineering Technology, University of Johannesburg, Johannesburg 2006, South AfricaDepartment of Electrical Engineering Technology, University of Johannesburg, Johannesburg 2006, South AfricaThe development and use of PV (Photovoltaic), Wind, and Hydro-based Distributed Generation (DG) is presently on the rise worldwide for improving stability and reliability, and reducing the power loss in the distribution system with reduced emission of harmful gases. A crucial issue addressed in this article, due to the increased penetration of DGs, is islanding operations. The detection of islanding is performed by a proposed v&f (voltage and frequency) index method. The reliability indices of the IEEE-33 and 118 radial bus distribution system after the detection of islanding by the proposed method is evaluated by considering the islanding issue as customer interruption. To mitigate the islanding, a reconfiguration strategy using Particle Swarm Optimization (PSO) is also performed and the proposed strategy is also evaluated with the conventional reconfiguration strategy of the distribution system.https://www.mdpi.com/1996-1073/16/7/3035distributed generation (DG)v&f (voltage and frequency) indexparticle swarm optimization (PSO)reconfigurationreliabilityENS |
spellingShingle | Sowmya Ramachandradurai Narayanan Krishnan Gulshan Sharma Pitshou N. Bokoro Islanding Detection with Reduced Non-Detection Zones and Restoration by Reconfiguration Energies distributed generation (DG) v&f (voltage and frequency) index particle swarm optimization (PSO) reconfiguration reliability ENS |
title | Islanding Detection with Reduced Non-Detection Zones and Restoration by Reconfiguration |
title_full | Islanding Detection with Reduced Non-Detection Zones and Restoration by Reconfiguration |
title_fullStr | Islanding Detection with Reduced Non-Detection Zones and Restoration by Reconfiguration |
title_full_unstemmed | Islanding Detection with Reduced Non-Detection Zones and Restoration by Reconfiguration |
title_short | Islanding Detection with Reduced Non-Detection Zones and Restoration by Reconfiguration |
title_sort | islanding detection with reduced non detection zones and restoration by reconfiguration |
topic | distributed generation (DG) v&f (voltage and frequency) index particle swarm optimization (PSO) reconfiguration reliability ENS |
url | https://www.mdpi.com/1996-1073/16/7/3035 |
work_keys_str_mv | AT sowmyaramachandradurai islandingdetectionwithreducednondetectionzonesandrestorationbyreconfiguration AT narayanankrishnan islandingdetectionwithreducednondetectionzonesandrestorationbyreconfiguration AT gulshansharma islandingdetectionwithreducednondetectionzonesandrestorationbyreconfiguration AT pitshounbokoro islandingdetectionwithreducednondetectionzonesandrestorationbyreconfiguration |