A standard sample determination method for the testing of smoke detectors and its application research
The stability of the standard sample plays a key role in the testing of the smoke detectors. A scientific and effective standard sample selection scheme is proposed in this paper. The repeatability and uniformity of the tested samples are evaluated before and after the environmental acceleration tes...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2020-01-01
|
Series: | E3S Web of Conferences |
Online Access: | https://www.e3s-conferences.org/articles/e3sconf/pdf/2020/45/e3sconf_iceeb2020_02035.pdf |
_version_ | 1818862537831088128 |
---|---|
author | Wang Tingting Wu Guoping Zhang Pei Zhang Dake |
author_facet | Wang Tingting Wu Guoping Zhang Pei Zhang Dake |
author_sort | Wang Tingting |
collection | DOAJ |
description | The stability of the standard sample plays a key role in the testing of the smoke detectors. A scientific and effective standard sample selection scheme is proposed in this paper. The repeatability and uniformity of the tested samples are evaluated before and after the environmental acceleration testing, and the most stable standard sample is obtained. At the same time, this paper explores the new application of the standard sample, which can be used in the calibration of the measuring ionization chamber (MIC). This work can greatly reduce the selection time and provide the standard samples for the laboratory of the smoke detectors testing which is scientific and reliable. At the same time, the difficult problem of the calibration of the measuring ionization chamber (MIC) is solved here. |
first_indexed | 2024-12-19T10:01:27Z |
format | Article |
id | doaj.art-b23880b02c7c418891efac0e7f70f20a |
institution | Directory Open Access Journal |
issn | 2267-1242 |
language | English |
last_indexed | 2024-12-19T10:01:27Z |
publishDate | 2020-01-01 |
publisher | EDP Sciences |
record_format | Article |
series | E3S Web of Conferences |
spelling | doaj.art-b23880b02c7c418891efac0e7f70f20a2022-12-21T20:26:39ZengEDP SciencesE3S Web of Conferences2267-12422020-01-011850203510.1051/e3sconf/202018502035e3sconf_iceeb2020_02035A standard sample determination method for the testing of smoke detectors and its application researchWang Tingting0Wu Guoping1Zhang Pei2Zhang Dake3Shanghai Institute of Quality Inspection and Technical ResearchShanghai Institute of Quality Inspection and Technical ResearchShanghai Institute of Quality Inspection and Technical ResearchHoneywell ACS(China) Co Ltd.The stability of the standard sample plays a key role in the testing of the smoke detectors. A scientific and effective standard sample selection scheme is proposed in this paper. The repeatability and uniformity of the tested samples are evaluated before and after the environmental acceleration testing, and the most stable standard sample is obtained. At the same time, this paper explores the new application of the standard sample, which can be used in the calibration of the measuring ionization chamber (MIC). This work can greatly reduce the selection time and provide the standard samples for the laboratory of the smoke detectors testing which is scientific and reliable. At the same time, the difficult problem of the calibration of the measuring ionization chamber (MIC) is solved here.https://www.e3s-conferences.org/articles/e3sconf/pdf/2020/45/e3sconf_iceeb2020_02035.pdf |
spellingShingle | Wang Tingting Wu Guoping Zhang Pei Zhang Dake A standard sample determination method for the testing of smoke detectors and its application research E3S Web of Conferences |
title | A standard sample determination method for the testing of smoke detectors and its application research |
title_full | A standard sample determination method for the testing of smoke detectors and its application research |
title_fullStr | A standard sample determination method for the testing of smoke detectors and its application research |
title_full_unstemmed | A standard sample determination method for the testing of smoke detectors and its application research |
title_short | A standard sample determination method for the testing of smoke detectors and its application research |
title_sort | standard sample determination method for the testing of smoke detectors and its application research |
url | https://www.e3s-conferences.org/articles/e3sconf/pdf/2020/45/e3sconf_iceeb2020_02035.pdf |
work_keys_str_mv | AT wangtingting astandardsampledeterminationmethodforthetestingofsmokedetectorsanditsapplicationresearch AT wuguoping astandardsampledeterminationmethodforthetestingofsmokedetectorsanditsapplicationresearch AT zhangpei astandardsampledeterminationmethodforthetestingofsmokedetectorsanditsapplicationresearch AT zhangdake astandardsampledeterminationmethodforthetestingofsmokedetectorsanditsapplicationresearch AT wangtingting standardsampledeterminationmethodforthetestingofsmokedetectorsanditsapplicationresearch AT wuguoping standardsampledeterminationmethodforthetestingofsmokedetectorsanditsapplicationresearch AT zhangpei standardsampledeterminationmethodforthetestingofsmokedetectorsanditsapplicationresearch AT zhangdake standardsampledeterminationmethodforthetestingofsmokedetectorsanditsapplicationresearch |