Universal test bench for repeatable multiparametric cochlear implant insertion tests

Introduction: In cochlear implant surgery, the insertion of the electrode array (EA) into the cochlea is critical as its implementation can influence the preservation of residual hearing. Insertion tests are the primary method for basic research on parameters influencing the insertion and help to fu...

Full description

Bibliographic Details
Main Authors: Böttcher-Rebmann Georg, Lange Vera, Schell Viktor, Cramer Jakob, Lenarz Thomas, Rau Thomas S.
Format: Article
Language:English
Published: De Gruyter 2023-09-01
Series:Current Directions in Biomedical Engineering
Subjects:
Online Access:https://doi.org/10.1515/cdbme-2023-1032
_version_ 1827780102637748224
author Böttcher-Rebmann Georg
Lange Vera
Schell Viktor
Cramer Jakob
Lenarz Thomas
Rau Thomas S.
author_facet Böttcher-Rebmann Georg
Lange Vera
Schell Viktor
Cramer Jakob
Lenarz Thomas
Rau Thomas S.
author_sort Böttcher-Rebmann Georg
collection DOAJ
description Introduction: In cochlear implant surgery, the insertion of the electrode array (EA) into the cochlea is critical as its implementation can influence the preservation of residual hearing. Insertion tests are the primary method for basic research on parameters influencing the insertion and help to further improve the design of EAs and surgical techniques. With automated insertion devices close to clinical application, a consensus on optimal insertion parameters is needed, which requires reliable testing methods. Moreover, the limited availability of EAs needs to be considered. We propose a test setup that provides high repeatability and flexibility for various research questions. Methods: Design requirements for multiple types of experiments such as variability of insertion speed or trajectory as well as cochlear geometry guided the computer aided design of the test bench. Moreover, repeated insertions with the same EA were supposed to be possible. To evaluate its functionality, insertion tests into a 3D printed cochlea model were performed and recorded. Results: The central components of the test bench are a linear actuator driving the EA and a goniometer changing the orientation of the target - a cochlea model or a specimen. A force sensor can be mounted below the target to measure forces in its frame of reference. The experimental results show high reproducibility of insertion forces for recurring trajectories with a single EA. Conclusion: The test bench enables reproducible insertion tests with a high number of repetitions and reduced EA usage. This allows a more detailed investigation of broadly discussed influences on the insertion such as the insertion speed or trajectory as well as cochlear geometry and can thereby drive future EA development.
first_indexed 2024-03-11T15:01:07Z
format Article
id doaj.art-b30a707f540d4157ae2cf340d363326e
institution Directory Open Access Journal
issn 2364-5504
language English
last_indexed 2024-03-11T15:01:07Z
publishDate 2023-09-01
publisher De Gruyter
record_format Article
series Current Directions in Biomedical Engineering
spelling doaj.art-b30a707f540d4157ae2cf340d363326e2023-10-30T07:58:11ZengDe GruyterCurrent Directions in Biomedical Engineering2364-55042023-09-019112612910.1515/cdbme-2023-1032Universal test bench for repeatable multiparametric cochlear implant insertion testsBöttcher-Rebmann Georg0Lange Vera1Schell Viktor2Cramer Jakob3Lenarz Thomas4Rau Thomas S.5Department for Otorhinolaryngology, Head and Neck Surgery and Cluster of Excellence EXC 2177/1 “Hearing4all”, Hannover Medical School, 30625Hannover, GermanyDepartment for Otorhinolaryngology, Head and Neck Surgery and Cluster of Excellence EXC 2177/1 “Hearing4all”, Hannover Medical School, 30625Hannover, GermanyDepartment for Otorhinolaryngology, Head and Neck Surgery and Cluster of Excellence EXC 2177/1 “Hearing4all”, Hannover Medical School, 30625Hannover, GermanyDepartment for Otorhinolaryngology, Head and Neck Surgery and Cluster of Excellence EXC 2177/1 “Hearing4all”, Hannover Medical School, 30625Hannover, GermanyDepartment for Otorhinolaryngology, Head and Neck Surgery and Cluster of Excellence EXC 2177/1 “Hearing4all”, Hannover Medical School, 30625Hannover, GermanyDepartment for Otorhinolaryngology, Head and Neck Surgery and Cluster of Excellence EXC 2177/1 “Hearing4all”, Hannover Medical School, 30625Hannover, GermanyIntroduction: In cochlear implant surgery, the insertion of the electrode array (EA) into the cochlea is critical as its implementation can influence the preservation of residual hearing. Insertion tests are the primary method for basic research on parameters influencing the insertion and help to further improve the design of EAs and surgical techniques. With automated insertion devices close to clinical application, a consensus on optimal insertion parameters is needed, which requires reliable testing methods. Moreover, the limited availability of EAs needs to be considered. We propose a test setup that provides high repeatability and flexibility for various research questions. Methods: Design requirements for multiple types of experiments such as variability of insertion speed or trajectory as well as cochlear geometry guided the computer aided design of the test bench. Moreover, repeated insertions with the same EA were supposed to be possible. To evaluate its functionality, insertion tests into a 3D printed cochlea model were performed and recorded. Results: The central components of the test bench are a linear actuator driving the EA and a goniometer changing the orientation of the target - a cochlea model or a specimen. A force sensor can be mounted below the target to measure forces in its frame of reference. The experimental results show high reproducibility of insertion forces for recurring trajectories with a single EA. Conclusion: The test bench enables reproducible insertion tests with a high number of repetitions and reduced EA usage. This allows a more detailed investigation of broadly discussed influences on the insertion such as the insertion speed or trajectory as well as cochlear geometry and can thereby drive future EA development.https://doi.org/10.1515/cdbme-2023-1032cochlear implantinsertion test benchinsertion trajectoryinsertion forcesinsertion speed
spellingShingle Böttcher-Rebmann Georg
Lange Vera
Schell Viktor
Cramer Jakob
Lenarz Thomas
Rau Thomas S.
Universal test bench for repeatable multiparametric cochlear implant insertion tests
Current Directions in Biomedical Engineering
cochlear implant
insertion test bench
insertion trajectory
insertion forces
insertion speed
title Universal test bench for repeatable multiparametric cochlear implant insertion tests
title_full Universal test bench for repeatable multiparametric cochlear implant insertion tests
title_fullStr Universal test bench for repeatable multiparametric cochlear implant insertion tests
title_full_unstemmed Universal test bench for repeatable multiparametric cochlear implant insertion tests
title_short Universal test bench for repeatable multiparametric cochlear implant insertion tests
title_sort universal test bench for repeatable multiparametric cochlear implant insertion tests
topic cochlear implant
insertion test bench
insertion trajectory
insertion forces
insertion speed
url https://doi.org/10.1515/cdbme-2023-1032
work_keys_str_mv AT bottcherrebmanngeorg universaltestbenchforrepeatablemultiparametriccochlearimplantinsertiontests
AT langevera universaltestbenchforrepeatablemultiparametriccochlearimplantinsertiontests
AT schellviktor universaltestbenchforrepeatablemultiparametriccochlearimplantinsertiontests
AT cramerjakob universaltestbenchforrepeatablemultiparametriccochlearimplantinsertiontests
AT lenarzthomas universaltestbenchforrepeatablemultiparametriccochlearimplantinsertiontests
AT rauthomass universaltestbenchforrepeatablemultiparametriccochlearimplantinsertiontests