Research on Measurement Methods of Radiation Dose in DSA Diagnosis

Doctors have to perform surgery under the guidance of X-rays during DSA intervention diagnosis. Long-term surgery may cause excessive radiation exposure to doctors. It is necessary to develop a small real-time radiation detector to measure the radiation exposure of the different tissues during the...

Full description

Bibliographic Details
Main Author: XIONG Wenjun, BO Yuqi, LIU Hongkai, HUANG Jinfeng, HUA Chengbin
Format: Article
Language:zho
Published: Editorial Board of Journal of Isotopes 2024-02-01
Series:Journal of Isotopes
Subjects:
Online Access:https://tws.xml-journal.net/cn/article/doi/10.7538/tws.2023.youxian.090
_version_ 1797324148643463168
author XIONG Wenjun, BO Yuqi, LIU Hongkai, HUANG Jinfeng, HUA Chengbin
author_facet XIONG Wenjun, BO Yuqi, LIU Hongkai, HUANG Jinfeng, HUA Chengbin
author_sort XIONG Wenjun, BO Yuqi, LIU Hongkai, HUANG Jinfeng, HUA Chengbin
collection DOAJ
description Doctors have to perform surgery under the guidance of X-rays during DSA intervention diagnosis. Long-term surgery may cause excessive radiation exposure to doctors. It is necessary to develop a small real-time radiation detector to measure the radiation exposure of the different tissues during the surgery, identify weak points in radiation shielding, and develop safer shielding plans. Based on chip technology, we developed a miniaturized, low-power, real-time radiation dose measurement module, which can be easily worn on the hand for real-time measurement of radiation dose. Using the MCNP simulation program, the energy response curve of the detector was calculated under different compensation thicknesses, and the optimal thickness of the compensation was obtained. Various parameters of the measurement module, such as repeatability, dose linearity, energy response, and radiation tolerance dose, were tested and verified. The results showed that the weight of the measurement module was less than 15 g, the volume was less than 15 mm×10 mm×5 mm, the upper limit of dose rate could be extended to 1 Sv/h, and the energy response was better than ±30% in the range of 10~250 keV. The radiation tolerance dose was better than 100 Gy. This work solved the problem of miniaturization of real-time radiation detector, provided radiation real-time measurement methods of exposure dose on the hand for doctors in DSA diagnosis and treatment, measuring X-ray. Through analysis of post data, it can analyze the radiation risk during the surgical process, thus providing technical means and data support for optimization of radiation protection.
first_indexed 2024-03-08T05:46:00Z
format Article
id doaj.art-b32f0426749a40f28b48c5f5a34b18a6
institution Directory Open Access Journal
issn 1000-7512
language zho
last_indexed 2024-03-08T05:46:00Z
publishDate 2024-02-01
publisher Editorial Board of Journal of Isotopes
record_format Article
series Journal of Isotopes
spelling doaj.art-b32f0426749a40f28b48c5f5a34b18a62024-02-05T08:59:58ZzhoEditorial Board of Journal of IsotopesJournal of Isotopes1000-75122024-02-013713035Research on Measurement Methods of Radiation Dose in DSA DiagnosisXIONG Wenjun, BO Yuqi, LIU Hongkai, HUANG Jinfeng, HUA Chengbin0Ratection Co., LTD., Guangzhou 510000, China Doctors have to perform surgery under the guidance of X-rays during DSA intervention diagnosis. Long-term surgery may cause excessive radiation exposure to doctors. It is necessary to develop a small real-time radiation detector to measure the radiation exposure of the different tissues during the surgery, identify weak points in radiation shielding, and develop safer shielding plans. Based on chip technology, we developed a miniaturized, low-power, real-time radiation dose measurement module, which can be easily worn on the hand for real-time measurement of radiation dose. Using the MCNP simulation program, the energy response curve of the detector was calculated under different compensation thicknesses, and the optimal thickness of the compensation was obtained. Various parameters of the measurement module, such as repeatability, dose linearity, energy response, and radiation tolerance dose, were tested and verified. The results showed that the weight of the measurement module was less than 15 g, the volume was less than 15 mm×10 mm×5 mm, the upper limit of dose rate could be extended to 1 Sv/h, and the energy response was better than ±30% in the range of 10~250 keV. The radiation tolerance dose was better than 100 Gy. This work solved the problem of miniaturization of real-time radiation detector, provided radiation real-time measurement methods of exposure dose on the hand for doctors in DSA diagnosis and treatment, measuring X-ray. Through analysis of post data, it can analyze the radiation risk during the surgical process, thus providing technical means and data support for optimization of radiation protection.https://tws.xml-journal.net/cn/article/doi/10.7538/tws.2023.youxian.090dsa diagnosissilicon detectorradiation monitoringintegrated circuitradiation dose
spellingShingle XIONG Wenjun, BO Yuqi, LIU Hongkai, HUANG Jinfeng, HUA Chengbin
Research on Measurement Methods of Radiation Dose in DSA Diagnosis
Journal of Isotopes
dsa diagnosis
silicon detector
radiation monitoring
integrated circuit
radiation dose
title Research on Measurement Methods of Radiation Dose in DSA Diagnosis
title_full Research on Measurement Methods of Radiation Dose in DSA Diagnosis
title_fullStr Research on Measurement Methods of Radiation Dose in DSA Diagnosis
title_full_unstemmed Research on Measurement Methods of Radiation Dose in DSA Diagnosis
title_short Research on Measurement Methods of Radiation Dose in DSA Diagnosis
title_sort research on measurement methods of radiation dose in dsa diagnosis
topic dsa diagnosis
silicon detector
radiation monitoring
integrated circuit
radiation dose
url https://tws.xml-journal.net/cn/article/doi/10.7538/tws.2023.youxian.090
work_keys_str_mv AT xiongwenjunboyuqiliuhongkaihuangjinfenghuachengbin researchonmeasurementmethodsofradiationdoseindsadiagnosis