Sensorless Robust Flatness-Based Control With Nonlinear Observer for Non-Ideal Parallel DC–AC Inverters
Parallel operation of multiple AC/DC inverters is favorable in hybrid AC/DC microgrids to avert consecutive conversion stages and increase the system’s efficacy. Yet, several emerging technical challenges impede the expansion of such layout such as the circulating currents, sensitiveness...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
IEEE
2022-01-01
|
Series: | IEEE Access |
Subjects: | |
Online Access: | https://ieeexplore.ieee.org/document/9775947/ |
_version_ | 1818552199789150208 |
---|---|
author | Ahmed Shahin Sayed Abulanwar Abdelhady Ghanem Mohammad E. M. Rizk Fujin Deng Serge Pierfederici Islam Ismael |
author_facet | Ahmed Shahin Sayed Abulanwar Abdelhady Ghanem Mohammad E. M. Rizk Fujin Deng Serge Pierfederici Islam Ismael |
author_sort | Ahmed Shahin |
collection | DOAJ |
description | Parallel operation of multiple AC/DC inverters is favorable in hybrid AC/DC microgrids to avert consecutive conversion stages and increase the system’s efficacy. Yet, several emerging technical challenges impede the expansion of such layout such as the circulating currents, sensitiveness to the input voltage disturbances, load variations and complexity of the control structures caused by using several required measurements. This paper proposes a one-loop sensorless controller which is based on the flatness technique for a non-isolated power supply consisting of n-parallel inverters. The proposed control scheme primarily relies on employing a nonlinear online observer to estimate the line inductor currents and the dc link voltage via information from the input voltage, output voltage, and load conditions to avoid using excessive sensors. In this way, the system reliability is improved by reducing burdens of the communication delays and/or the failures, signal noise, thus the system is featured by simple control. Besides, the system entire losses are modeled by equivalent voltage sources and one current source which implicitly represent all types of the losses by using an online nonlinear estimator for the control purposes. The proposed controller not only has high dynamic performance, wide-bandwidth, low voltage THD but also robust to the abrupt variations in the load and the input voltage. To validate the applicability of the proposed control method and the observer, both simulations and experimental investigations are performed for two paralleled three-phase inverters setup. The obtained results assure the effectiveness of the proposed control method in regulating the output voltage of the parallel DC/AC inverters with fewer number of the sensors against the fluctuations of the input dc voltage and the load perturbations. |
first_indexed | 2024-12-12T09:10:05Z |
format | Article |
id | doaj.art-b4837cbff07641f3b9d31a1afd106f8b |
institution | Directory Open Access Journal |
issn | 2169-3536 |
language | English |
last_indexed | 2024-12-12T09:10:05Z |
publishDate | 2022-01-01 |
publisher | IEEE |
record_format | Article |
series | IEEE Access |
spelling | doaj.art-b4837cbff07641f3b9d31a1afd106f8b2022-12-22T00:29:32ZengIEEEIEEE Access2169-35362022-01-0110539405395310.1109/ACCESS.2022.31758479775947Sensorless Robust Flatness-Based Control With Nonlinear Observer for Non-Ideal Parallel DC–AC InvertersAhmed Shahin0https://orcid.org/0000-0002-0564-5188Sayed Abulanwar1https://orcid.org/0000-0002-3396-4020Abdelhady Ghanem2https://orcid.org/0000-0002-6178-6022Mohammad E. M. Rizk3https://orcid.org/0000-0002-4507-0956Fujin Deng4https://orcid.org/0000-0002-9832-004XSerge Pierfederici5https://orcid.org/0000-0003-3682-6317Islam Ismael6https://orcid.org/0000-0002-9249-0443Electrical Engineering Department, Faculty of Engineering, Mansoura University, Mansoura, EgyptElectrical Engineering Department, Faculty of Engineering, Mansoura University, Mansoura, EgyptElectrical Engineering Department, Faculty of Engineering, Mansoura University, Mansoura, EgyptElectrical Engineering Department, Faculty of Engineering, Mansoura University, Mansoura, EgyptJiangsu Key Laboratory of Smart Grid Technology and Equipment, School of Electrical Engineering, Southeast University, Nanjing, ChinaLEMTA, ENSEM, University of Lorraine, Vandoeuvre-lès-Nancy, FranceElectrical Engineering Department, Faculty of Engineering, Mansoura University, Mansoura, EgyptParallel operation of multiple AC/DC inverters is favorable in hybrid AC/DC microgrids to avert consecutive conversion stages and increase the system’s efficacy. Yet, several emerging technical challenges impede the expansion of such layout such as the circulating currents, sensitiveness to the input voltage disturbances, load variations and complexity of the control structures caused by using several required measurements. This paper proposes a one-loop sensorless controller which is based on the flatness technique for a non-isolated power supply consisting of n-parallel inverters. The proposed control scheme primarily relies on employing a nonlinear online observer to estimate the line inductor currents and the dc link voltage via information from the input voltage, output voltage, and load conditions to avoid using excessive sensors. In this way, the system reliability is improved by reducing burdens of the communication delays and/or the failures, signal noise, thus the system is featured by simple control. Besides, the system entire losses are modeled by equivalent voltage sources and one current source which implicitly represent all types of the losses by using an online nonlinear estimator for the control purposes. The proposed controller not only has high dynamic performance, wide-bandwidth, low voltage THD but also robust to the abrupt variations in the load and the input voltage. To validate the applicability of the proposed control method and the observer, both simulations and experimental investigations are performed for two paralleled three-phase inverters setup. The obtained results assure the effectiveness of the proposed control method in regulating the output voltage of the parallel DC/AC inverters with fewer number of the sensors against the fluctuations of the input dc voltage and the load perturbations.https://ieeexplore.ieee.org/document/9775947/Flatness controllosses estimationparallel inverterssensorless controlnonlinear observer |
spellingShingle | Ahmed Shahin Sayed Abulanwar Abdelhady Ghanem Mohammad E. M. Rizk Fujin Deng Serge Pierfederici Islam Ismael Sensorless Robust Flatness-Based Control With Nonlinear Observer for Non-Ideal Parallel DC–AC Inverters IEEE Access Flatness control losses estimation parallel inverters sensorless control nonlinear observer |
title | Sensorless Robust Flatness-Based Control With Nonlinear Observer for Non-Ideal Parallel DC–AC Inverters |
title_full | Sensorless Robust Flatness-Based Control With Nonlinear Observer for Non-Ideal Parallel DC–AC Inverters |
title_fullStr | Sensorless Robust Flatness-Based Control With Nonlinear Observer for Non-Ideal Parallel DC–AC Inverters |
title_full_unstemmed | Sensorless Robust Flatness-Based Control With Nonlinear Observer for Non-Ideal Parallel DC–AC Inverters |
title_short | Sensorless Robust Flatness-Based Control With Nonlinear Observer for Non-Ideal Parallel DC–AC Inverters |
title_sort | sensorless robust flatness based control with nonlinear observer for non ideal parallel dc x2013 ac inverters |
topic | Flatness control losses estimation parallel inverters sensorless control nonlinear observer |
url | https://ieeexplore.ieee.org/document/9775947/ |
work_keys_str_mv | AT ahmedshahin sensorlessrobustflatnessbasedcontrolwithnonlinearobserverfornonidealparalleldcx2013acinverters AT sayedabulanwar sensorlessrobustflatnessbasedcontrolwithnonlinearobserverfornonidealparalleldcx2013acinverters AT abdelhadyghanem sensorlessrobustflatnessbasedcontrolwithnonlinearobserverfornonidealparalleldcx2013acinverters AT mohammademrizk sensorlessrobustflatnessbasedcontrolwithnonlinearobserverfornonidealparalleldcx2013acinverters AT fujindeng sensorlessrobustflatnessbasedcontrolwithnonlinearobserverfornonidealparalleldcx2013acinverters AT sergepierfederici sensorlessrobustflatnessbasedcontrolwithnonlinearobserverfornonidealparalleldcx2013acinverters AT islamismael sensorlessrobustflatnessbasedcontrolwithnonlinearobserverfornonidealparalleldcx2013acinverters |