Comparison of assessment of diaphragm function using speckle tracking between patients with successful and failed weaning: a multicentre, observational, pilot study

Abstract Background Diaphragmatic ultrasound has been increasingly used to evaluate diaphragm function. However, current diaphragmatic ultrasound parameters provide indirect estimates of diaphragmatic contractile function, and the predictive value is controversial. Two-dimensional (2D) speckle track...

Full description

Bibliographic Details
Main Authors: Qiancheng Xu, Xiao Yang, Yan Qian, Chang Hu, Weihua Lu, Shuhan Cai, Bo Hu, Jianguo Li
Format: Article
Language:English
Published: BMC 2022-12-01
Series:BMC Pulmonary Medicine
Subjects:
Online Access:https://doi.org/10.1186/s12890-022-02260-z
_version_ 1811208063096455168
author Qiancheng Xu
Xiao Yang
Yan Qian
Chang Hu
Weihua Lu
Shuhan Cai
Bo Hu
Jianguo Li
author_facet Qiancheng Xu
Xiao Yang
Yan Qian
Chang Hu
Weihua Lu
Shuhan Cai
Bo Hu
Jianguo Li
author_sort Qiancheng Xu
collection DOAJ
description Abstract Background Diaphragmatic ultrasound has been increasingly used to evaluate diaphragm function. However, current diaphragmatic ultrasound parameters provide indirect estimates of diaphragmatic contractile function, and the predictive value is controversial. Two-dimensional (2D) speckle tracking is an effective technology for measuring tissue deformation and can be used to measure diaphragm longitudinal strain (DLS) to assess diaphragm function. The purpose of this study was to determine the feasibility and reproducibility of DLS quantification by 2D speckle tracking and to determine whether maximal DLS could be used to predict weaning outcomes. Methods This study was performed in the intensive care unit of two teaching hospitals, and was divided into two studies. Study A was a prospective study to evaluate the feasibility, reliability, and repeatability of speckle tracking in assessing DLS in healthy subjects and mechanically ventilated patients. Study B was a multicentre retrospective study to assess the use of maximal DLS measured by speckle tracking in predicting weaning outcomes. Results Twenty-five healthy subjects and twenty mechanically ventilated patients were enrolled in Study A. Diaphragmatic speckle tracking was easily accessible. The intra- and interoperator reliability were good to excellent under conditions of eupnoea, deep breathing, and mechanical ventilation. The intraclass correlation coefficient (ICC) ranged from 0.78 to 0.95. Ninety-six patients (fifty-nine patients were successfully weaned) were included in Study B. DLS exhibited a fair linear relationship with both the diaphragmatic thickening fraction (DTF) (R2 = 0.73, p < 0.0001) and diaphragmatic excursion (DE) (R2 = 0.61, p < 0.0001). For the prediction of successful weaning, the areas under the ROC curves of DLS, diaphragmatic thickening fraction DTF, RSBI, and DE were 0.794, 0.794, 0.723, and 0.728, respectively. The best cut-off value for predicting the weaning success of DLS was less than -21%, which had the highest sensitivity of 89.19% and specificity of 64.41%. Conclusions Diaphragmatic strain quantification using speckle tracking is easy to obtain in healthy subjects and mechanically ventilated patients and has a high predictive value for mechanical weaning. However, this method offers no advantage over RSBI. Future research should assess its value as a predictor of weaning. Trial registration This study was registered in the Chinese Clinical Trial Register (ChiCTR), ChiCTR2100049816. Registered 10 August 2021. http://www.chictr.org.cn/showproj.aspx?proj=131790
first_indexed 2024-04-12T04:16:01Z
format Article
id doaj.art-b4ae8d10e6774dd9bdf92bb87d8517a9
institution Directory Open Access Journal
issn 1471-2466
language English
last_indexed 2024-04-12T04:16:01Z
publishDate 2022-12-01
publisher BMC
record_format Article
series BMC Pulmonary Medicine
spelling doaj.art-b4ae8d10e6774dd9bdf92bb87d8517a92022-12-22T03:48:24ZengBMCBMC Pulmonary Medicine1471-24662022-12-0122111210.1186/s12890-022-02260-zComparison of assessment of diaphragm function using speckle tracking between patients with successful and failed weaning: a multicentre, observational, pilot studyQiancheng Xu0Xiao Yang1Yan Qian2Chang Hu3Weihua Lu4Shuhan Cai5Bo Hu6Jianguo Li7Department of Critical Care Medicine, Zhongnan Hospital of Wuhan UniversityDepartment of Critical Care Medicine, Zhongnan Hospital of Wuhan UniversityDepartment of Emergency Intensive Care Unit, EastChina Normal UniversityDepartment of Critical Care Medicine, Zhongnan Hospital of Wuhan UniversityDepartment of Critical Care Medicine, The First Affiliated Hospital of Wannan Medical College (Yijishan Hospital of Wannan Medical College)Department of Critical Care Medicine, Zhongnan Hospital of Wuhan UniversityDepartment of Critical Care Medicine, Zhongnan Hospital of Wuhan UniversityDepartment of Critical Care Medicine, Zhongnan Hospital of Wuhan UniversityAbstract Background Diaphragmatic ultrasound has been increasingly used to evaluate diaphragm function. However, current diaphragmatic ultrasound parameters provide indirect estimates of diaphragmatic contractile function, and the predictive value is controversial. Two-dimensional (2D) speckle tracking is an effective technology for measuring tissue deformation and can be used to measure diaphragm longitudinal strain (DLS) to assess diaphragm function. The purpose of this study was to determine the feasibility and reproducibility of DLS quantification by 2D speckle tracking and to determine whether maximal DLS could be used to predict weaning outcomes. Methods This study was performed in the intensive care unit of two teaching hospitals, and was divided into two studies. Study A was a prospective study to evaluate the feasibility, reliability, and repeatability of speckle tracking in assessing DLS in healthy subjects and mechanically ventilated patients. Study B was a multicentre retrospective study to assess the use of maximal DLS measured by speckle tracking in predicting weaning outcomes. Results Twenty-five healthy subjects and twenty mechanically ventilated patients were enrolled in Study A. Diaphragmatic speckle tracking was easily accessible. The intra- and interoperator reliability were good to excellent under conditions of eupnoea, deep breathing, and mechanical ventilation. The intraclass correlation coefficient (ICC) ranged from 0.78 to 0.95. Ninety-six patients (fifty-nine patients were successfully weaned) were included in Study B. DLS exhibited a fair linear relationship with both the diaphragmatic thickening fraction (DTF) (R2 = 0.73, p < 0.0001) and diaphragmatic excursion (DE) (R2 = 0.61, p < 0.0001). For the prediction of successful weaning, the areas under the ROC curves of DLS, diaphragmatic thickening fraction DTF, RSBI, and DE were 0.794, 0.794, 0.723, and 0.728, respectively. The best cut-off value for predicting the weaning success of DLS was less than -21%, which had the highest sensitivity of 89.19% and specificity of 64.41%. Conclusions Diaphragmatic strain quantification using speckle tracking is easy to obtain in healthy subjects and mechanically ventilated patients and has a high predictive value for mechanical weaning. However, this method offers no advantage over RSBI. Future research should assess its value as a predictor of weaning. Trial registration This study was registered in the Chinese Clinical Trial Register (ChiCTR), ChiCTR2100049816. Registered 10 August 2021. http://www.chictr.org.cn/showproj.aspx?proj=131790https://doi.org/10.1186/s12890-022-02260-zSpeckle trackingDiaphragmUltrasoundStrainWeaningMechanical ventilation
spellingShingle Qiancheng Xu
Xiao Yang
Yan Qian
Chang Hu
Weihua Lu
Shuhan Cai
Bo Hu
Jianguo Li
Comparison of assessment of diaphragm function using speckle tracking between patients with successful and failed weaning: a multicentre, observational, pilot study
BMC Pulmonary Medicine
Speckle tracking
Diaphragm
Ultrasound
Strain
Weaning
Mechanical ventilation
title Comparison of assessment of diaphragm function using speckle tracking between patients with successful and failed weaning: a multicentre, observational, pilot study
title_full Comparison of assessment of diaphragm function using speckle tracking between patients with successful and failed weaning: a multicentre, observational, pilot study
title_fullStr Comparison of assessment of diaphragm function using speckle tracking between patients with successful and failed weaning: a multicentre, observational, pilot study
title_full_unstemmed Comparison of assessment of diaphragm function using speckle tracking between patients with successful and failed weaning: a multicentre, observational, pilot study
title_short Comparison of assessment of diaphragm function using speckle tracking between patients with successful and failed weaning: a multicentre, observational, pilot study
title_sort comparison of assessment of diaphragm function using speckle tracking between patients with successful and failed weaning a multicentre observational pilot study
topic Speckle tracking
Diaphragm
Ultrasound
Strain
Weaning
Mechanical ventilation
url https://doi.org/10.1186/s12890-022-02260-z
work_keys_str_mv AT qianchengxu comparisonofassessmentofdiaphragmfunctionusingspeckletrackingbetweenpatientswithsuccessfulandfailedweaningamulticentreobservationalpilotstudy
AT xiaoyang comparisonofassessmentofdiaphragmfunctionusingspeckletrackingbetweenpatientswithsuccessfulandfailedweaningamulticentreobservationalpilotstudy
AT yanqian comparisonofassessmentofdiaphragmfunctionusingspeckletrackingbetweenpatientswithsuccessfulandfailedweaningamulticentreobservationalpilotstudy
AT changhu comparisonofassessmentofdiaphragmfunctionusingspeckletrackingbetweenpatientswithsuccessfulandfailedweaningamulticentreobservationalpilotstudy
AT weihualu comparisonofassessmentofdiaphragmfunctionusingspeckletrackingbetweenpatientswithsuccessfulandfailedweaningamulticentreobservationalpilotstudy
AT shuhancai comparisonofassessmentofdiaphragmfunctionusingspeckletrackingbetweenpatientswithsuccessfulandfailedweaningamulticentreobservationalpilotstudy
AT bohu comparisonofassessmentofdiaphragmfunctionusingspeckletrackingbetweenpatientswithsuccessfulandfailedweaningamulticentreobservationalpilotstudy
AT jianguoli comparisonofassessmentofdiaphragmfunctionusingspeckletrackingbetweenpatientswithsuccessfulandfailedweaningamulticentreobservationalpilotstudy