EFFECT OF FILL RATIO ON EVAPORATOR WALL TEMPERATURE IN A LOOP THERMOSYPHON USED IN ELECTRONIC COOLING APPLICATIONS

This paper presents the effect of filling ratio on thermal performance;of a loop thermosyphon. The experimental setup consists of an evaporator, a condenser, a riser and a downcomer. The dimensions of the loop thermosyphon under consideration were chosen so that they are mostly suitable for use i...

Full description

Bibliographic Details
Main Authors: Samah Ihsan Adnan, Aouf Abdulrahman Ahmad, Adnan Adulamir Abdulrasool
Format: Article
Language:Arabic
Published: Mustansiriyah University/College of Engineering 2020-03-01
Series:Journal of Engineering and Sustainable Development
Subjects:
Online Access:https://jeasd.uomustansiriyah.edu.iq/index.php/jeasd/article/view/145
_version_ 1797683290357891072
author Samah Ihsan Adnan
Aouf Abdulrahman Ahmad
Adnan Adulamir Abdulrasool
author_facet Samah Ihsan Adnan
Aouf Abdulrahman Ahmad
Adnan Adulamir Abdulrasool
author_sort Samah Ihsan Adnan
collection DOAJ
description This paper presents the effect of filling ratio on thermal performance;of a loop thermosyphon. The experimental setup consists of an evaporator, a condenser, a riser and a downcomer. The dimensions of the loop thermosyphon under consideration were chosen so that they are mostly suitable for use in the cooling of electronic components. Distilled water was used as a working fluid. Experiments were carried out to estimate the performance of the loop thermosyphon for a range of input power from 10 to 100 W. Four fill ratios were considered in the present work, namely; 15%, 25%, 50% and 85%. Results showed that the maximum value of wall temperature in evaporator was 95°C, at 100 W input power and 15% fill ratio. The fill ratio of 50% gave the minimum evaporator wall temperature which was 80°C. Increasing fill ratio tends to decrease the evaporator wall temperature for evaporator.  
first_indexed 2024-03-12T00:12:22Z
format Article
id doaj.art-b4ce30ac62ed4bb1871c469873682c4b
institution Directory Open Access Journal
issn 2520-0917
2520-0925
language Arabic
last_indexed 2024-03-12T00:12:22Z
publishDate 2020-03-01
publisher Mustansiriyah University/College of Engineering
record_format Article
series Journal of Engineering and Sustainable Development
spelling doaj.art-b4ce30ac62ed4bb1871c469873682c4b2023-09-15T22:01:19ZaraMustansiriyah University/College of EngineeringJournal of Engineering and Sustainable Development2520-09172520-09252020-03-01242 EFFECT OF FILL RATIO ON EVAPORATOR WALL TEMPERATURE IN A LOOP THERMOSYPHON USED IN ELECTRONIC COOLING APPLICATIONSSamah Ihsan Adnan0Aouf Abdulrahman Ahmad1Adnan Adulamir Abdulrasool2Mechanical Engineering Department, College of Engineering, Mustansiriyah University, Baghdad, IraqMechanical Engineering Department, College of Engineering, Mustansiriyah University, Baghdad, IraqMechanical Engineering Department, College of Engineering, Mustansiriyah University, Baghdad, Iraq This paper presents the effect of filling ratio on thermal performance;of a loop thermosyphon. The experimental setup consists of an evaporator, a condenser, a riser and a downcomer. The dimensions of the loop thermosyphon under consideration were chosen so that they are mostly suitable for use in the cooling of electronic components. Distilled water was used as a working fluid. Experiments were carried out to estimate the performance of the loop thermosyphon for a range of input power from 10 to 100 W. Four fill ratios were considered in the present work, namely; 15%, 25%, 50% and 85%. Results showed that the maximum value of wall temperature in evaporator was 95°C, at 100 W input power and 15% fill ratio. The fill ratio of 50% gave the minimum evaporator wall temperature which was 80°C. Increasing fill ratio tends to decrease the evaporator wall temperature for evaporator.   https://jeasd.uomustansiriyah.edu.iq/index.php/jeasd/article/view/145loop heat pipethermosyphonfill ratiosaturation temperature
spellingShingle Samah Ihsan Adnan
Aouf Abdulrahman Ahmad
Adnan Adulamir Abdulrasool
EFFECT OF FILL RATIO ON EVAPORATOR WALL TEMPERATURE IN A LOOP THERMOSYPHON USED IN ELECTRONIC COOLING APPLICATIONS
Journal of Engineering and Sustainable Development
loop heat pipe
thermosyphon
fill ratio
saturation temperature
title EFFECT OF FILL RATIO ON EVAPORATOR WALL TEMPERATURE IN A LOOP THERMOSYPHON USED IN ELECTRONIC COOLING APPLICATIONS
title_full EFFECT OF FILL RATIO ON EVAPORATOR WALL TEMPERATURE IN A LOOP THERMOSYPHON USED IN ELECTRONIC COOLING APPLICATIONS
title_fullStr EFFECT OF FILL RATIO ON EVAPORATOR WALL TEMPERATURE IN A LOOP THERMOSYPHON USED IN ELECTRONIC COOLING APPLICATIONS
title_full_unstemmed EFFECT OF FILL RATIO ON EVAPORATOR WALL TEMPERATURE IN A LOOP THERMOSYPHON USED IN ELECTRONIC COOLING APPLICATIONS
title_short EFFECT OF FILL RATIO ON EVAPORATOR WALL TEMPERATURE IN A LOOP THERMOSYPHON USED IN ELECTRONIC COOLING APPLICATIONS
title_sort effect of fill ratio on evaporator wall temperature in a loop thermosyphon used in electronic cooling applications
topic loop heat pipe
thermosyphon
fill ratio
saturation temperature
url https://jeasd.uomustansiriyah.edu.iq/index.php/jeasd/article/view/145
work_keys_str_mv AT samahihsanadnan effectoffillratioonevaporatorwalltemperatureinaloopthermosyphonusedinelectroniccoolingapplications
AT aoufabdulrahmanahmad effectoffillratioonevaporatorwalltemperatureinaloopthermosyphonusedinelectroniccoolingapplications
AT adnanadulamirabdulrasool effectoffillratioonevaporatorwalltemperatureinaloopthermosyphonusedinelectroniccoolingapplications