3.6 mW Active-Electrode ECG/ETI Sensor System Using Wideband Low-Noise Instrumentation Amplifier and High Impedance Balanced Current Driver

An active electrode (AE) and back-end (BE) integrated system for enhanced electrocardiogram (ECG)/electrode-tissue impedance (ETI) measurement is proposed. The AE consists of a balanced current driver and a preamplifier. To increase the output impedance, the current driver uses a matched current sou...

Full description

Bibliographic Details
Main Authors: Xuan Tien Nguyen, Muhammad Ali, Jong-Wook Lee
Format: Article
Language:English
Published: MDPI AG 2023-02-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/23/5/2536
_version_ 1797614393250283520
author Xuan Tien Nguyen
Muhammad Ali
Jong-Wook Lee
author_facet Xuan Tien Nguyen
Muhammad Ali
Jong-Wook Lee
author_sort Xuan Tien Nguyen
collection DOAJ
description An active electrode (AE) and back-end (BE) integrated system for enhanced electrocardiogram (ECG)/electrode-tissue impedance (ETI) measurement is proposed. The AE consists of a balanced current driver and a preamplifier. To increase the output impedance, the current driver uses a matched current source and sink, which operates under negative feedback. To increase the linear input range, a new source degeneration method is proposed. The preamplifier is realized using a capacitively-coupled instrumentation amplifier (CCIA) with a ripple-reduction loop (RRL). Compared to the traditional Miller compensation, active frequency feedback compensation (AFFC) achieves bandwidth extension using the reduced size of the compensation capacitor. The BE performs three types of signal sensing: ECG, band power (BP), and impedance (IMP) data. The BP channel is used to detect the Q-, R-, and S-wave (QRS) complex in the ECG signal. The IMP channel measures the resistance and reactance of the electrode-tissue. The integrated circuits for the ECG/ETI system are realized in the 180 nm CMOS process and occupy a 1.26 mm<sup>2</sup> area. The measured results show that the current driver supplies a relatively high current (>600 μA<sub>pp</sub>) and achieves a high output impedance (1 MΩ at 500 kHz). The ETI system can detect resistance and capacitance in the ranges of 10 mΩ–3 kΩ and 100 nF–100 μF, respectively. The ECG/ETI system consumes 3.6 mW using a single 1.8 V supply.
first_indexed 2024-03-11T07:10:44Z
format Article
id doaj.art-b4d717150ade464cbfd3b1d8b0d1fb0d
institution Directory Open Access Journal
issn 1424-8220
language English
last_indexed 2024-03-11T07:10:44Z
publishDate 2023-02-01
publisher MDPI AG
record_format Article
series Sensors
spelling doaj.art-b4d717150ade464cbfd3b1d8b0d1fb0d2023-11-17T08:36:08ZengMDPI AGSensors1424-82202023-02-01235253610.3390/s230525363.6 mW Active-Electrode ECG/ETI Sensor System Using Wideband Low-Noise Instrumentation Amplifier and High Impedance Balanced Current DriverXuan Tien Nguyen0Muhammad Ali1Jong-Wook Lee2Information and Communication System-on-Chip (SoC) Research Center, School of Electronics and Information, Kyung Hee University, Yongin 17104, Republic of KoreaInformation and Communication System-on-Chip (SoC) Research Center, School of Electronics and Information, Kyung Hee University, Yongin 17104, Republic of KoreaInformation and Communication System-on-Chip (SoC) Research Center, School of Electronics and Information, Kyung Hee University, Yongin 17104, Republic of KoreaAn active electrode (AE) and back-end (BE) integrated system for enhanced electrocardiogram (ECG)/electrode-tissue impedance (ETI) measurement is proposed. The AE consists of a balanced current driver and a preamplifier. To increase the output impedance, the current driver uses a matched current source and sink, which operates under negative feedback. To increase the linear input range, a new source degeneration method is proposed. The preamplifier is realized using a capacitively-coupled instrumentation amplifier (CCIA) with a ripple-reduction loop (RRL). Compared to the traditional Miller compensation, active frequency feedback compensation (AFFC) achieves bandwidth extension using the reduced size of the compensation capacitor. The BE performs three types of signal sensing: ECG, band power (BP), and impedance (IMP) data. The BP channel is used to detect the Q-, R-, and S-wave (QRS) complex in the ECG signal. The IMP channel measures the resistance and reactance of the electrode-tissue. The integrated circuits for the ECG/ETI system are realized in the 180 nm CMOS process and occupy a 1.26 mm<sup>2</sup> area. The measured results show that the current driver supplies a relatively high current (>600 μA<sub>pp</sub>) and achieves a high output impedance (1 MΩ at 500 kHz). The ETI system can detect resistance and capacitance in the ranges of 10 mΩ–3 kΩ and 100 nF–100 μF, respectively. The ECG/ETI system consumes 3.6 mW using a single 1.8 V supply.https://www.mdpi.com/1424-8220/23/5/2536active electrodebioimpedanceelectrocardiogrampreamplifierintegrated circuit
spellingShingle Xuan Tien Nguyen
Muhammad Ali
Jong-Wook Lee
3.6 mW Active-Electrode ECG/ETI Sensor System Using Wideband Low-Noise Instrumentation Amplifier and High Impedance Balanced Current Driver
Sensors
active electrode
bioimpedance
electrocardiogram
preamplifier
integrated circuit
title 3.6 mW Active-Electrode ECG/ETI Sensor System Using Wideband Low-Noise Instrumentation Amplifier and High Impedance Balanced Current Driver
title_full 3.6 mW Active-Electrode ECG/ETI Sensor System Using Wideband Low-Noise Instrumentation Amplifier and High Impedance Balanced Current Driver
title_fullStr 3.6 mW Active-Electrode ECG/ETI Sensor System Using Wideband Low-Noise Instrumentation Amplifier and High Impedance Balanced Current Driver
title_full_unstemmed 3.6 mW Active-Electrode ECG/ETI Sensor System Using Wideband Low-Noise Instrumentation Amplifier and High Impedance Balanced Current Driver
title_short 3.6 mW Active-Electrode ECG/ETI Sensor System Using Wideband Low-Noise Instrumentation Amplifier and High Impedance Balanced Current Driver
title_sort 3 6 mw active electrode ecg eti sensor system using wideband low noise instrumentation amplifier and high impedance balanced current driver
topic active electrode
bioimpedance
electrocardiogram
preamplifier
integrated circuit
url https://www.mdpi.com/1424-8220/23/5/2536
work_keys_str_mv AT xuantiennguyen 36mwactiveelectrodeecgetisensorsystemusingwidebandlownoiseinstrumentationamplifierandhighimpedancebalancedcurrentdriver
AT muhammadali 36mwactiveelectrodeecgetisensorsystemusingwidebandlownoiseinstrumentationamplifierandhighimpedancebalancedcurrentdriver
AT jongwooklee 36mwactiveelectrodeecgetisensorsystemusingwidebandlownoiseinstrumentationamplifierandhighimpedancebalancedcurrentdriver