Dosimetric Parameter Simulation of Domestic 6711 125I Seed Source

The dose rate constant, radial dose function, one-dimensional anisotropy function and two-dimensional anisotropy function of domestic 6711 particle source were simulated by MCNP software. The error between the dose rate constant and the recommended value reported by TG 43-U1 was -0.83%. The radial d...

Full description

Bibliographic Details
Main Author: HANG Zhongbin1, LIU Chuanfeng2, TENG Zhongbin1, GENG Xuan1, HU Kaixuan1, JIA Minghan1, LI Qiao1, GAO Fei1, WANG Hongyu1, WEI Kexin1, SONG Mingzhe1, LIU Yuntao1
Format: Article
Language:zho
Published: Editorial Board of Journal of Isotopes 2023-06-01
Series:Journal of Isotopes
Subjects:
Online Access:https://tws.xml-journal.net/cn/article/doi/10.7538/tws.2022.youxian.085
_version_ 1797323863260921856
author HANG Zhongbin1, LIU Chuanfeng2, TENG Zhongbin1, GENG Xuan1, HU Kaixuan1, JIA Minghan1, LI Qiao1, GAO Fei1, WANG Hongyu1, WEI Kexin1, SONG Mingzhe1, LIU Yuntao1
author_facet HANG Zhongbin1, LIU Chuanfeng2, TENG Zhongbin1, GENG Xuan1, HU Kaixuan1, JIA Minghan1, LI Qiao1, GAO Fei1, WANG Hongyu1, WEI Kexin1, SONG Mingzhe1, LIU Yuntao1
author_sort HANG Zhongbin1, LIU Chuanfeng2, TENG Zhongbin1, GENG Xuan1, HU Kaixuan1, JIA Minghan1, LI Qiao1, GAO Fei1, WANG Hongyu1, WEI Kexin1, SONG Mingzhe1, LIU Yuntao1
collection DOAJ
description The dose rate constant, radial dose function, one-dimensional anisotropy function and two-dimensional anisotropy function of domestic 6711 particle source were simulated by MCNP software. The error between the dose rate constant and the recommended value reported by TG 43-U1 was -0.83%. The radial dose function in the range of 0.05-10 cm was obtained, and the fifth-order polynomial fitting of the data in the range of 0.25-10 cm was proposed to improve the accuracy of the fitting function. The one-dimensional anisotropy function and the two-dimensional anisotropy function in the range of 0.25-7 cm are obtained, and compared with the relevant literature, it can be seen that the difference of the structure of the domestic type 6711 particle core will cause the phenomenon of the one-dimensional anisotropy function and the two-dimensional anisotropy function.
first_indexed 2024-03-08T05:34:15Z
format Article
id doaj.art-b4dbe52c948f4bb5bd10705af9522ebf
institution Directory Open Access Journal
issn 1000-7512
language zho
last_indexed 2024-03-08T05:34:15Z
publishDate 2023-06-01
publisher Editorial Board of Journal of Isotopes
record_format Article
series Journal of Isotopes
spelling doaj.art-b4dbe52c948f4bb5bd10705af9522ebf2024-02-06T01:53:13ZzhoEditorial Board of Journal of IsotopesJournal of Isotopes1000-75122023-06-01366572578Dosimetric Parameter Simulation of Domestic 6711 125I Seed SourceHANG Zhongbin1, LIU Chuanfeng2, TENG Zhongbin1, GENG Xuan1, HU Kaixuan1, JIA Minghan1, LI Qiao1, GAO Fei1, WANG Hongyu1, WEI Kexin1, SONG Mingzhe1, LIU Yuntao101. China Institute of Atomic Energy, Key Laboratory of Measurement and Calibration Technology, Beijing 102413, China 2. National Institute of Metrology, Beijing 100029, ChinaThe dose rate constant, radial dose function, one-dimensional anisotropy function and two-dimensional anisotropy function of domestic 6711 particle source were simulated by MCNP software. The error between the dose rate constant and the recommended value reported by TG 43-U1 was -0.83%. The radial dose function in the range of 0.05-10 cm was obtained, and the fifth-order polynomial fitting of the data in the range of 0.25-10 cm was proposed to improve the accuracy of the fitting function. The one-dimensional anisotropy function and the two-dimensional anisotropy function in the range of 0.25-7 cm are obtained, and compared with the relevant literature, it can be seen that the difference of the structure of the domestic type 6711 particle core will cause the phenomenon of the one-dimensional anisotropy function and the two-dimensional anisotropy function.https://tws.xml-journal.net/cn/article/doi/10.7538/tws.2022.youxian.085125i seed sourcethe monte carlo methoddosimetric parameters
spellingShingle HANG Zhongbin1, LIU Chuanfeng2, TENG Zhongbin1, GENG Xuan1, HU Kaixuan1, JIA Minghan1, LI Qiao1, GAO Fei1, WANG Hongyu1, WEI Kexin1, SONG Mingzhe1, LIU Yuntao1
Dosimetric Parameter Simulation of Domestic 6711 125I Seed Source
Journal of Isotopes
125i seed source
the monte carlo method
dosimetric parameters
title Dosimetric Parameter Simulation of Domestic 6711 125I Seed Source
title_full Dosimetric Parameter Simulation of Domestic 6711 125I Seed Source
title_fullStr Dosimetric Parameter Simulation of Domestic 6711 125I Seed Source
title_full_unstemmed Dosimetric Parameter Simulation of Domestic 6711 125I Seed Source
title_short Dosimetric Parameter Simulation of Domestic 6711 125I Seed Source
title_sort dosimetric parameter simulation of domestic 6711 125i seed source
topic 125i seed source
the monte carlo method
dosimetric parameters
url https://tws.xml-journal.net/cn/article/doi/10.7538/tws.2022.youxian.085
work_keys_str_mv AT hangzhongbin1liuchuanfeng2tengzhongbin1gengxuan1hukaixuan1jiaminghan1liqiao1gaofei1wanghongyu1weikexin1songmingzhe1liuyuntao1 dosimetricparametersimulationofdomestic6711125iseedsource