Determined the bulk etch rate VB by different methods for nuclear track detector CR-39

In this study, the bulk etch rate (VB) was measured by three different methods forCR-39 with a thickness of 200µm and an area of (1 × 1 cm2), where CR_39 was irradiated through from Am241source with energy of alpha particles is 2.6MeV and at an angle of fall perpendicular to the surface of the CR-39...

Full description

Bibliographic Details
Main Authors: Zainab Mohialdeen, Mushtaq Al-Jubbori
Format: Article
Language:Arabic
Published: College of Education for Pure Sciences 2023-03-01
Series:مجلة التربية والعلم
Subjects:
Online Access:https://edusj.mosuljournals.com/article_176776_963d04a9e61b20e97834796001d35088.pdf
_version_ 1811161446711558144
author Zainab Mohialdeen
Mushtaq Al-Jubbori
author_facet Zainab Mohialdeen
Mushtaq Al-Jubbori
author_sort Zainab Mohialdeen
collection DOAJ
description In this study, the bulk etch rate (VB) was measured by three different methods forCR-39 with a thickness of 200µm and an area of (1 × 1 cm2), where CR_39 was irradiated through from Am241source with energy of alpha particles is 2.6MeV and at an angle of fall perpendicular to the surface of the CR-39 detector, the detector etching with (NaOH) at a concentration of 6.25N and (70 ± 1°C) and showing the effects formed on the surface of the detector with time periods ranging from (0.25h) and the formed effects were photographed In the detector at different eching times using an optical microscope of the type (XSZ-H Series Biological Microscope) equipped with a digital camera of the type (MADC_5A) connected to a personal computer, in order to find the length, thickness and diameters of the track formed on the surface of the detector.VB determind by methods are: Removed thickness method, the second method, the saturation track method, and the diameter-length method (D_L method), as the first method does not require irradiation of the detector, but the other two methods require irradiation of the detector and measurement of lengths and diameters And the time of proving the effect, and we found that the values of VB rate for the three methods, the removed thickness method, the saturation track method, and the diameter-length of the effect ((D_L method) respectively are:, (1.206, 1.204, 1.271 (µm/h) and compare the results between the mentioned methods, as we found that they are close.
first_indexed 2024-04-10T06:14:18Z
format Article
id doaj.art-b4fbe93453144cdc80248667de2eac3c
institution Directory Open Access Journal
issn 1812-125X
2664-2530
language Arabic
last_indexed 2024-04-10T06:14:18Z
publishDate 2023-03-01
publisher College of Education for Pure Sciences
record_format Article
series مجلة التربية والعلم
spelling doaj.art-b4fbe93453144cdc80248667de2eac3c2023-03-02T10:05:14ZaraCollege of Education for Pure Sciencesمجلة التربية والعلم1812-125X2664-25302023-03-01321475510.33899/edusj.2023.137160.1297176776Determined the bulk etch rate VB by different methods for nuclear track detector CR-39Zainab Mohialdeen0Mushtaq Al-Jubbori1Department of Physics college of education for pure Sciences University of MosulDepartment of Physics, College of Education for Pure Science, Mosul University, Mosul-IraqIn this study, the bulk etch rate (VB) was measured by three different methods forCR-39 with a thickness of 200µm and an area of (1 × 1 cm2), where CR_39 was irradiated through from Am241source with energy of alpha particles is 2.6MeV and at an angle of fall perpendicular to the surface of the CR-39 detector, the detector etching with (NaOH) at a concentration of 6.25N and (70 ± 1°C) and showing the effects formed on the surface of the detector with time periods ranging from (0.25h) and the formed effects were photographed In the detector at different eching times using an optical microscope of the type (XSZ-H Series Biological Microscope) equipped with a digital camera of the type (MADC_5A) connected to a personal computer, in order to find the length, thickness and diameters of the track formed on the surface of the detector.VB determind by methods are: Removed thickness method, the second method, the saturation track method, and the diameter-length method (D_L method), as the first method does not require irradiation of the detector, but the other two methods require irradiation of the detector and measurement of lengths and diameters And the time of proving the effect, and we found that the values of VB rate for the three methods, the removed thickness method, the saturation track method, and the diameter-length of the effect ((D_L method) respectively are:, (1.206, 1.204, 1.271 (µm/h) and compare the results between the mentioned methods, as we found that they are close.https://edusj.mosuljournals.com/article_176776_963d04a9e61b20e97834796001d35088.pdfalpha particlescr_39 detectorbulk etch ratetrack depthremoved layer
spellingShingle Zainab Mohialdeen
Mushtaq Al-Jubbori
Determined the bulk etch rate VB by different methods for nuclear track detector CR-39
مجلة التربية والعلم
alpha particles
cr_39 detector
bulk etch rate
track depth
removed layer
title Determined the bulk etch rate VB by different methods for nuclear track detector CR-39
title_full Determined the bulk etch rate VB by different methods for nuclear track detector CR-39
title_fullStr Determined the bulk etch rate VB by different methods for nuclear track detector CR-39
title_full_unstemmed Determined the bulk etch rate VB by different methods for nuclear track detector CR-39
title_short Determined the bulk etch rate VB by different methods for nuclear track detector CR-39
title_sort determined the bulk etch rate vb by different methods for nuclear track detector cr 39
topic alpha particles
cr_39 detector
bulk etch rate
track depth
removed layer
url https://edusj.mosuljournals.com/article_176776_963d04a9e61b20e97834796001d35088.pdf
work_keys_str_mv AT zainabmohialdeen determinedthebulketchratevbbydifferentmethodsfornucleartrackdetectorcr39
AT mushtaqaljubbori determinedthebulketchratevbbydifferentmethodsfornucleartrackdetectorcr39