Correlative 3D Imaging and Microfluidic Modelling of Human Pulmonary Lymphatics using Immunohistochemistry and High-resolution μCT

Abstract Lung lymphatics maintain fluid homoeostasis by providing a drainage system that returns fluid, cells and metabolites to the circulatory system. The 3D structure of the human pulmonary lymphatic network is essential to lung function, but it is poorly characterised. Image-based 3D mathematica...

Full description

Bibliographic Details
Main Authors: Stephanie K. Robinson, Jonathan J. Ramsden, Jane Warner, Peter M. Lackie, Tiina Roose
Format: Article
Language:English
Published: Nature Portfolio 2019-04-01
Series:Scientific Reports
Online Access:https://doi.org/10.1038/s41598-019-42794-7
_version_ 1818344026231799808
author Stephanie K. Robinson
Jonathan J. Ramsden
Jane Warner
Peter M. Lackie
Tiina Roose
author_facet Stephanie K. Robinson
Jonathan J. Ramsden
Jane Warner
Peter M. Lackie
Tiina Roose
author_sort Stephanie K. Robinson
collection DOAJ
description Abstract Lung lymphatics maintain fluid homoeostasis by providing a drainage system that returns fluid, cells and metabolites to the circulatory system. The 3D structure of the human pulmonary lymphatic network is essential to lung function, but it is poorly characterised. Image-based 3D mathematical modelling of pulmonary lymphatic microfluidics has been limited by the lack of accurate and representative image geometries. This is due to the microstructural similarity of the lymphatics to the blood vessel network, the lack of lymphatic-specific biomarkers, the technical limitations associated with image resolution in 3D, and sectioning artefacts present in 2D techniques. We present a method that combines lymphatic specific (D240 antibody) immunohistochemistry (IHC), optimised high-resolution X-ray microfocus computed tomography (μCT) and finite-element mathematical modelling to assess the function of human peripheral lung tissue. The initial results identify lymphatic heterogeneity within and between lung tissue. Lymphatic vessel volume fraction and fractal dimension significantly decreases away from the lung pleural surface (p < 0.001, n = 25 and p < 0.01, n = 20, respectively). Microfluidic modelling successfully shows that in lung tissue the fluid derived from the blood vessels drains through the interstitium into the lymphatic vessel network and this drainage is different in the subpleural space compared to the intralobular space. When comparing lung tissue from health and disease, human pulmonary lymphatics were significantly different across five morphometric measures used in this study (p ≤ 0.0001). This proof of principle study establishes a new engineering technology and workflow for further studies of pulmonary lymphatics and demonstrates for the first time the combination of correlative μCT and IHC to enable 3D mathematical modelling of human lung microfluidics at micrometre resolution.
first_indexed 2024-12-13T16:39:56Z
format Article
id doaj.art-b58fc3cc5e714adfbe6a2de50ebebe48
institution Directory Open Access Journal
issn 2045-2322
language English
last_indexed 2024-12-13T16:39:56Z
publishDate 2019-04-01
publisher Nature Portfolio
record_format Article
series Scientific Reports
spelling doaj.art-b58fc3cc5e714adfbe6a2de50ebebe482022-12-21T23:38:18ZengNature PortfolioScientific Reports2045-23222019-04-019111410.1038/s41598-019-42794-7Correlative 3D Imaging and Microfluidic Modelling of Human Pulmonary Lymphatics using Immunohistochemistry and High-resolution μCTStephanie K. Robinson0Jonathan J. Ramsden1Jane Warner2Peter M. Lackie3Tiina Roose4Bioengineering Sciences Research Group, School of Engineering, Faculty of Engineering and Physical Science, University of SouthamptonClinical and Experimental Sciences, Faculty of Medicine, Southampton General Hospital, University of SouthamptonClinical and Experimental Sciences, Faculty of Medicine, Southampton General Hospital, University of SouthamptonClinical and Experimental Sciences, Faculty of Medicine, Southampton General Hospital, University of SouthamptonBioengineering Sciences Research Group, School of Engineering, Faculty of Engineering and Physical Science, University of SouthamptonAbstract Lung lymphatics maintain fluid homoeostasis by providing a drainage system that returns fluid, cells and metabolites to the circulatory system. The 3D structure of the human pulmonary lymphatic network is essential to lung function, but it is poorly characterised. Image-based 3D mathematical modelling of pulmonary lymphatic microfluidics has been limited by the lack of accurate and representative image geometries. This is due to the microstructural similarity of the lymphatics to the blood vessel network, the lack of lymphatic-specific biomarkers, the technical limitations associated with image resolution in 3D, and sectioning artefacts present in 2D techniques. We present a method that combines lymphatic specific (D240 antibody) immunohistochemistry (IHC), optimised high-resolution X-ray microfocus computed tomography (μCT) and finite-element mathematical modelling to assess the function of human peripheral lung tissue. The initial results identify lymphatic heterogeneity within and between lung tissue. Lymphatic vessel volume fraction and fractal dimension significantly decreases away from the lung pleural surface (p < 0.001, n = 25 and p < 0.01, n = 20, respectively). Microfluidic modelling successfully shows that in lung tissue the fluid derived from the blood vessels drains through the interstitium into the lymphatic vessel network and this drainage is different in the subpleural space compared to the intralobular space. When comparing lung tissue from health and disease, human pulmonary lymphatics were significantly different across five morphometric measures used in this study (p ≤ 0.0001). This proof of principle study establishes a new engineering technology and workflow for further studies of pulmonary lymphatics and demonstrates for the first time the combination of correlative μCT and IHC to enable 3D mathematical modelling of human lung microfluidics at micrometre resolution.https://doi.org/10.1038/s41598-019-42794-7
spellingShingle Stephanie K. Robinson
Jonathan J. Ramsden
Jane Warner
Peter M. Lackie
Tiina Roose
Correlative 3D Imaging and Microfluidic Modelling of Human Pulmonary Lymphatics using Immunohistochemistry and High-resolution μCT
Scientific Reports
title Correlative 3D Imaging and Microfluidic Modelling of Human Pulmonary Lymphatics using Immunohistochemistry and High-resolution μCT
title_full Correlative 3D Imaging and Microfluidic Modelling of Human Pulmonary Lymphatics using Immunohistochemistry and High-resolution μCT
title_fullStr Correlative 3D Imaging and Microfluidic Modelling of Human Pulmonary Lymphatics using Immunohistochemistry and High-resolution μCT
title_full_unstemmed Correlative 3D Imaging and Microfluidic Modelling of Human Pulmonary Lymphatics using Immunohistochemistry and High-resolution μCT
title_short Correlative 3D Imaging and Microfluidic Modelling of Human Pulmonary Lymphatics using Immunohistochemistry and High-resolution μCT
title_sort correlative 3d imaging and microfluidic modelling of human pulmonary lymphatics using immunohistochemistry and high resolution μct
url https://doi.org/10.1038/s41598-019-42794-7
work_keys_str_mv AT stephaniekrobinson correlative3dimagingandmicrofluidicmodellingofhumanpulmonarylymphaticsusingimmunohistochemistryandhighresolutionmct
AT jonathanjramsden correlative3dimagingandmicrofluidicmodellingofhumanpulmonarylymphaticsusingimmunohistochemistryandhighresolutionmct
AT janewarner correlative3dimagingandmicrofluidicmodellingofhumanpulmonarylymphaticsusingimmunohistochemistryandhighresolutionmct
AT petermlackie correlative3dimagingandmicrofluidicmodellingofhumanpulmonarylymphaticsusingimmunohistochemistryandhighresolutionmct
AT tiinaroose correlative3dimagingandmicrofluidicmodellingofhumanpulmonarylymphaticsusingimmunohistochemistryandhighresolutionmct