Correlation between impulse oscillometry parameters and asthma control in an adult population

Miguel Ángel Díaz Palacios,1 David Hervás Marín,2 Ana Giner Valero,1 Noelia Colomer Hernández,1 Carla Torán Barona,1 Dolores Hernández Fernández de Rojas11Department of Allergy, Hospital Universitari La Fe, Valen...

Full description

Bibliographic Details
Main Authors: Díaz Palacios MÁ, Hervás Marín D, Giner Valero A, Colomer Hernández N, Torán Barona C, Hernández Fernández de Rojas D
Format: Article
Language:English
Published: Dove Medical Press 2019-07-01
Series:Journal of Asthma and Allergy
Subjects:
Online Access:https://www.dovepress.com/correlation-between-impulse-oscillometry-parameters-and-asthma-control-peer-reviewed-article-JAA
_version_ 1811221970516180992
author Díaz Palacios MÁ
Hervás Marín D
Giner Valero A
Colomer Hernández N
Torán Barona C
Hernández Fernández de Rojas D
author_facet Díaz Palacios MÁ
Hervás Marín D
Giner Valero A
Colomer Hernández N
Torán Barona C
Hernández Fernández de Rojas D
author_sort Díaz Palacios MÁ
collection DOAJ
description Miguel Ángel Díaz Palacios,1 David Hervás Marín,2 Ana Giner Valero,1 Noelia Colomer Hernández,1 Carla Torán Barona,1 Dolores Hernández Fernández de Rojas11Department of Allergy, Hospital Universitari La Fe, Valencia, Spain; 2Department of Biostatistics, Instituto de Investigación Sanitaria La Fe, Valencia, SpainPurpose: Impulse oscillometry (IOS) has been proposed as an alternative test to evaluate the obstruction of small airways and to detect changes in airways earlier than spirometry. In this study, we sought to determine the utility and association of IOS parameters with spirometry and asthma control in an adult population.Patients and methods: Adults 14–82 years of age with asthma were classified into uncontrolled asthma (n=48), partially controlled asthma (n=45), and controlled asthma (n=49) groups, and characterized with fractional exhaled nitric oxide (FENO), IOS, and spirometry in a transversal analysis planned as a one-visit study. The basic parameters evaluated in IOS are resistance at 5 Hz (R5), an index affected by the large and small airway; resistance at 20 Hz (R20), an index of the resistance of large airways; difference between R5 and R20 (R5–R20), indicative of the function of the small peripheral airways; reactance at 5 Hz (X5), indicative of the capacitive reactance in the small peripheral airways; resonance frequency (Fres), the intermediate frequency at which the reactance is null, and reactance area (XA), which represents the total reactance (area under the curve) at all frequencies between 5 Hz to Fres.Results: There were statistical differences between groups in standard spirometry and IOS parameters reflecting small peripheral airways (R5, R10, R5–R20, Fres, XA and X5) (P<0.001). Accuracy of IOS and/or spirometry to discriminate between controlled asthma vs partially controlled asthma and uncontrolled asthma was low (AUC=0.61). Using linear regression models, we found a good association between spirometry and IOS. In order to evaluate IOS as an alternative or supplementary method for spirometry, we designed a predictive model for spirometry from IOS applying a penalized regression model (Lasso). Then, we compared the original spirometry values with the values obtained from the predictive model using Bland–Altman plots, and the models showed an acceptable bias in the case of FEV1/FVC, FEV1%, and FVC%.Conclusion: IOS did not show a discriminative capacity to correctly classify patients according to the degree of asthma control. However, values of IOS showed good association with values of spirometry. IOS could be considered as an alternative and accurate complement to spirometry in adults. In a predictive model, spirometry values estimated from IOS tended to overestimate in low values of “real” spirometry and underestimate in high values.Keywords: asthma, lung function tests, oscillometry, spirometry
first_indexed 2024-04-12T08:09:14Z
format Article
id doaj.art-b5d36df15073439bab19e44ec1710a34
institution Directory Open Access Journal
issn 1178-6965
language English
last_indexed 2024-04-12T08:09:14Z
publishDate 2019-07-01
publisher Dove Medical Press
record_format Article
series Journal of Asthma and Allergy
spelling doaj.art-b5d36df15073439bab19e44ec1710a342022-12-22T03:41:03ZengDove Medical PressJournal of Asthma and Allergy1178-69652019-07-01Volume 1219520347199Correlation between impulse oscillometry parameters and asthma control in an adult populationDíaz Palacios MÁHervás Marín DGiner Valero AColomer Hernández NTorán Barona CHernández Fernández de Rojas DMiguel Ángel Díaz Palacios,1 David Hervás Marín,2 Ana Giner Valero,1 Noelia Colomer Hernández,1 Carla Torán Barona,1 Dolores Hernández Fernández de Rojas11Department of Allergy, Hospital Universitari La Fe, Valencia, Spain; 2Department of Biostatistics, Instituto de Investigación Sanitaria La Fe, Valencia, SpainPurpose: Impulse oscillometry (IOS) has been proposed as an alternative test to evaluate the obstruction of small airways and to detect changes in airways earlier than spirometry. In this study, we sought to determine the utility and association of IOS parameters with spirometry and asthma control in an adult population.Patients and methods: Adults 14–82 years of age with asthma were classified into uncontrolled asthma (n=48), partially controlled asthma (n=45), and controlled asthma (n=49) groups, and characterized with fractional exhaled nitric oxide (FENO), IOS, and spirometry in a transversal analysis planned as a one-visit study. The basic parameters evaluated in IOS are resistance at 5 Hz (R5), an index affected by the large and small airway; resistance at 20 Hz (R20), an index of the resistance of large airways; difference between R5 and R20 (R5–R20), indicative of the function of the small peripheral airways; reactance at 5 Hz (X5), indicative of the capacitive reactance in the small peripheral airways; resonance frequency (Fres), the intermediate frequency at which the reactance is null, and reactance area (XA), which represents the total reactance (area under the curve) at all frequencies between 5 Hz to Fres.Results: There were statistical differences between groups in standard spirometry and IOS parameters reflecting small peripheral airways (R5, R10, R5–R20, Fres, XA and X5) (P<0.001). Accuracy of IOS and/or spirometry to discriminate between controlled asthma vs partially controlled asthma and uncontrolled asthma was low (AUC=0.61). Using linear regression models, we found a good association between spirometry and IOS. In order to evaluate IOS as an alternative or supplementary method for spirometry, we designed a predictive model for spirometry from IOS applying a penalized regression model (Lasso). Then, we compared the original spirometry values with the values obtained from the predictive model using Bland–Altman plots, and the models showed an acceptable bias in the case of FEV1/FVC, FEV1%, and FVC%.Conclusion: IOS did not show a discriminative capacity to correctly classify patients according to the degree of asthma control. However, values of IOS showed good association with values of spirometry. IOS could be considered as an alternative and accurate complement to spirometry in adults. In a predictive model, spirometry values estimated from IOS tended to overestimate in low values of “real” spirometry and underestimate in high values.Keywords: asthma, lung function tests, oscillometry, spirometryhttps://www.dovepress.com/correlation-between-impulse-oscillometry-parameters-and-asthma-control-peer-reviewed-article-JAAAsthma. Control. Impulse Oscillometry.Spirometery
spellingShingle Díaz Palacios MÁ
Hervás Marín D
Giner Valero A
Colomer Hernández N
Torán Barona C
Hernández Fernández de Rojas D
Correlation between impulse oscillometry parameters and asthma control in an adult population
Journal of Asthma and Allergy
Asthma. Control. Impulse Oscillometry.Spirometery
title Correlation between impulse oscillometry parameters and asthma control in an adult population
title_full Correlation between impulse oscillometry parameters and asthma control in an adult population
title_fullStr Correlation between impulse oscillometry parameters and asthma control in an adult population
title_full_unstemmed Correlation between impulse oscillometry parameters and asthma control in an adult population
title_short Correlation between impulse oscillometry parameters and asthma control in an adult population
title_sort correlation between impulse oscillometry parameters and asthma control in an adult population
topic Asthma. Control. Impulse Oscillometry.Spirometery
url https://www.dovepress.com/correlation-between-impulse-oscillometry-parameters-and-asthma-control-peer-reviewed-article-JAA
work_keys_str_mv AT diazpalaciosma correlationbetweenimpulseoscillometryparametersandasthmacontrolinanadultpopulation
AT hervasmarind correlationbetweenimpulseoscillometryparametersandasthmacontrolinanadultpopulation
AT ginervaleroa correlationbetweenimpulseoscillometryparametersandasthmacontrolinanadultpopulation
AT colomerhernandezn correlationbetweenimpulseoscillometryparametersandasthmacontrolinanadultpopulation
AT toranbaronac correlationbetweenimpulseoscillometryparametersandasthmacontrolinanadultpopulation
AT hernandezfernandezderojasd correlationbetweenimpulseoscillometryparametersandasthmacontrolinanadultpopulation