The Mechanism and Diagnosis of Insulation Deterioration Caused by Moisture Ingress into Oil-Impregnated Paper Bushing

The healthy state of insulation in oil-impregnated bushings is traditionally evaluated by tanδ and capacitance at power frequency and mostly at 10 kV in the test standard. However, there has frequently been insulation accidents induced by moisture ingress (MI) for bushings that have passed...

Full description

Bibliographic Details
Main Authors: Bo Qi, Quanmin Dai, Chengrong Li, Zipeng Zeng, Mingli Fu, Ran Zhuo
Format: Article
Language:English
Published: MDPI AG 2018-06-01
Series:Energies
Subjects:
Online Access:http://www.mdpi.com/1996-1073/11/6/1496
_version_ 1811263125130838016
author Bo Qi
Quanmin Dai
Chengrong Li
Zipeng Zeng
Mingli Fu
Ran Zhuo
author_facet Bo Qi
Quanmin Dai
Chengrong Li
Zipeng Zeng
Mingli Fu
Ran Zhuo
author_sort Bo Qi
collection DOAJ
description The healthy state of insulation in oil-impregnated bushings is traditionally evaluated by tanδ and capacitance at power frequency and mostly at 10 kV in the test standard. However, there has frequently been insulation accidents induced by moisture ingress (MI) for bushings that have passed the standard. The mechanism and new diagnostic features for MI into bushings were not distinct enough and an accurate test method is urgently needed research. To address this technical gap, a bushing model with a transparent sheath was designed and an ultrasonic humidifier device was adopted to simulate the environment of MI in bushings and recorded by digital camera. The parameters of dielectric dissipation factor, capacitance, partial discharge (PD), frequency domain response, and moisture content in oil were measured at room temperature with time. The results presented that both the increment dissipation factor at low frequency of 0.001 Hz and the increment dissipation factor of 1.2 Um could be used for detecting the earlier insulation defect of oil-impregnated paper (OIP) bushings. The phase resolved partial discharge (PRPD) can serve as the diagnostic basis of the severe state (S3) of insulation deterioration caused by MI into bushings around the phases of 0–117°, 151–303°, and 325–360°. The research findings would provide a useful reference for the condition diagnosis and maintenance of OIP bushings. Especially, the increment detection of Frequency Domain Spectroscopy (FDS) at the frequency of 1 mHz and 10 kHz was recommended firstly for the operative bushings in real sites.
first_indexed 2024-04-12T19:39:04Z
format Article
id doaj.art-b5df352f2f814cdfb94c9aa1bcc3d550
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-04-12T19:39:04Z
publishDate 2018-06-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-b5df352f2f814cdfb94c9aa1bcc3d5502022-12-22T03:19:08ZengMDPI AGEnergies1996-10732018-06-01116149610.3390/en11061496en11061496The Mechanism and Diagnosis of Insulation Deterioration Caused by Moisture Ingress into Oil-Impregnated Paper BushingBo Qi0Quanmin Dai1Chengrong Li2Zipeng Zeng3Mingli Fu4Ran Zhuo5State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Chang Ping District, Beijing 102206, ChinaState Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Chang Ping District, Beijing 102206, ChinaState Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Chang Ping District, Beijing 102206, ChinaState Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Chang Ping District, Beijing 102206, ChinaElectric Power Research Institute of China Southern Power Grid, Guangzhou 510530, ChinaElectric Power Research Institute of China Southern Power Grid, Guangzhou 510530, ChinaThe healthy state of insulation in oil-impregnated bushings is traditionally evaluated by tanδ and capacitance at power frequency and mostly at 10 kV in the test standard. However, there has frequently been insulation accidents induced by moisture ingress (MI) for bushings that have passed the standard. The mechanism and new diagnostic features for MI into bushings were not distinct enough and an accurate test method is urgently needed research. To address this technical gap, a bushing model with a transparent sheath was designed and an ultrasonic humidifier device was adopted to simulate the environment of MI in bushings and recorded by digital camera. The parameters of dielectric dissipation factor, capacitance, partial discharge (PD), frequency domain response, and moisture content in oil were measured at room temperature with time. The results presented that both the increment dissipation factor at low frequency of 0.001 Hz and the increment dissipation factor of 1.2 Um could be used for detecting the earlier insulation defect of oil-impregnated paper (OIP) bushings. The phase resolved partial discharge (PRPD) can serve as the diagnostic basis of the severe state (S3) of insulation deterioration caused by MI into bushings around the phases of 0–117°, 151–303°, and 325–360°. The research findings would provide a useful reference for the condition diagnosis and maintenance of OIP bushings. Especially, the increment detection of Frequency Domain Spectroscopy (FDS) at the frequency of 1 mHz and 10 kHz was recommended firstly for the operative bushings in real sites.http://www.mdpi.com/1996-1073/11/6/1496bushingmoisture ingressinsulation deteriorationfault diagnosis
spellingShingle Bo Qi
Quanmin Dai
Chengrong Li
Zipeng Zeng
Mingli Fu
Ran Zhuo
The Mechanism and Diagnosis of Insulation Deterioration Caused by Moisture Ingress into Oil-Impregnated Paper Bushing
Energies
bushing
moisture ingress
insulation deterioration
fault diagnosis
title The Mechanism and Diagnosis of Insulation Deterioration Caused by Moisture Ingress into Oil-Impregnated Paper Bushing
title_full The Mechanism and Diagnosis of Insulation Deterioration Caused by Moisture Ingress into Oil-Impregnated Paper Bushing
title_fullStr The Mechanism and Diagnosis of Insulation Deterioration Caused by Moisture Ingress into Oil-Impregnated Paper Bushing
title_full_unstemmed The Mechanism and Diagnosis of Insulation Deterioration Caused by Moisture Ingress into Oil-Impregnated Paper Bushing
title_short The Mechanism and Diagnosis of Insulation Deterioration Caused by Moisture Ingress into Oil-Impregnated Paper Bushing
title_sort mechanism and diagnosis of insulation deterioration caused by moisture ingress into oil impregnated paper bushing
topic bushing
moisture ingress
insulation deterioration
fault diagnosis
url http://www.mdpi.com/1996-1073/11/6/1496
work_keys_str_mv AT boqi themechanismanddiagnosisofinsulationdeteriorationcausedbymoistureingressintooilimpregnatedpaperbushing
AT quanmindai themechanismanddiagnosisofinsulationdeteriorationcausedbymoistureingressintooilimpregnatedpaperbushing
AT chengrongli themechanismanddiagnosisofinsulationdeteriorationcausedbymoistureingressintooilimpregnatedpaperbushing
AT zipengzeng themechanismanddiagnosisofinsulationdeteriorationcausedbymoistureingressintooilimpregnatedpaperbushing
AT minglifu themechanismanddiagnosisofinsulationdeteriorationcausedbymoistureingressintooilimpregnatedpaperbushing
AT ranzhuo themechanismanddiagnosisofinsulationdeteriorationcausedbymoistureingressintooilimpregnatedpaperbushing
AT boqi mechanismanddiagnosisofinsulationdeteriorationcausedbymoistureingressintooilimpregnatedpaperbushing
AT quanmindai mechanismanddiagnosisofinsulationdeteriorationcausedbymoistureingressintooilimpregnatedpaperbushing
AT chengrongli mechanismanddiagnosisofinsulationdeteriorationcausedbymoistureingressintooilimpregnatedpaperbushing
AT zipengzeng mechanismanddiagnosisofinsulationdeteriorationcausedbymoistureingressintooilimpregnatedpaperbushing
AT minglifu mechanismanddiagnosisofinsulationdeteriorationcausedbymoistureingressintooilimpregnatedpaperbushing
AT ranzhuo mechanismanddiagnosisofinsulationdeteriorationcausedbymoistureingressintooilimpregnatedpaperbushing