Analysis of the joint operation of the expander-generator unit and air heat pump
Calculations of the energy efficiency of the expander-generator unit under various operating conditions during heating of natural gas in front of the expander using a heat pump unit were carried out. It is shown that the introduction of expander-generator units in the gas supply system of the Republ...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2023-01-01
|
Series: | E3S Web of Conferences |
Online Access: | https://www.e3s-conferences.org/articles/e3sconf/pdf/2023/56/e3sconf_wfces2023_01016.pdf |
Summary: | Calculations of the energy efficiency of the expander-generator unit under various operating conditions during heating of natural gas in front of the expander using a heat pump unit were carried out. It is shown that the introduction of expander-generator units in the gas supply system of the Republic of Uzekistan, with a properly selected gas heating system, can be thermodynamically and technically and economically advantageous. The results of the thermodynamic analysis of the developed energy-technological complex in the production of electricity are presented. |
---|---|
ISSN: | 2267-1242 |