Validity of the CALERA Research Sensor to Assess Body Core Temperature during Maximum Exercise in Patients with Heart Failure

(1) Background: It is important to monitor the body core temperature (Tc) of individuals with chronic heart failure (CHF) during rest or exercise, as they are susceptible to complications. Gastrointestinal capsules are a robust indicator of the Tc at rest and during exercise. A practical and non-inv...

Full description

Bibliographic Details
Main Authors: Antonia Kaltsatou, Maria Anifanti, Andreas D. Flouris, Georgia Xiromerisiou, Evangelia Kouidi
Format: Article
Language:English
Published: MDPI AG 2024-01-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/24/3/807
_version_ 1797318277131665408
author Antonia Kaltsatou
Maria Anifanti
Andreas D. Flouris
Georgia Xiromerisiou
Evangelia Kouidi
author_facet Antonia Kaltsatou
Maria Anifanti
Andreas D. Flouris
Georgia Xiromerisiou
Evangelia Kouidi
author_sort Antonia Kaltsatou
collection DOAJ
description (1) Background: It is important to monitor the body core temperature (Tc) of individuals with chronic heart failure (CHF) during rest or exercise, as they are susceptible to complications. Gastrointestinal capsules are a robust indicator of the Tc at rest and during exercise. A practical and non-invasive sensor called CALERA Research was recently introduced, promising accuracy, sensitivity, continuous real-time analysis, repeatability, and reproducibility. This study aimed to assess the validity of the CALERA Research sensor when monitoring patients with CHF during periods of rest, throughout brief cardiopulmonary exercise testing, and during their subsequent recovery. (2) Methods: Twelve male CHF patients volunteered to participate in a 70-min protocol in a laboratory at 28 °C and 39% relative humidity. After remaining calm for 20 min, they underwent a symptom-limited stress test combined with ergospirometry on a treadmill, followed by 40 min of seated recovery. The Tc was continuously monitored by both Tc devices. (3) Results: The Tc values from the CALERA Research sensor and the gastrointestinal sensor showed no associations at rest (r = 0.056, <i>p</i> = 0.154) and during exercise (r = −0.015, <i>p</i> = 0.829) and a weak association during recovery (r = 0.292, <i>p</i> < 0.001). The Cohen’s effect size of the differences between the two Tc assessment methods for rest, exercise, and recovery was 1.04 (large), 0.18 (none), and 0.45 (small), respectively. The 95% limit of agreement for the CALERA Research sensor was −0.057 ± 1.03 °C. (4) Conclusions: The CALERA sensor is a practical and, potentially, promising device, but it does not provide an accurate Tc estimation in CHF patients at rest, during brief exercise testing, and during recovery.
first_indexed 2024-03-08T03:49:04Z
format Article
id doaj.art-b6a980d75b1c47a9ae7d777b0c98483b
institution Directory Open Access Journal
issn 1424-8220
language English
last_indexed 2024-03-08T03:49:04Z
publishDate 2024-01-01
publisher MDPI AG
record_format Article
series Sensors
spelling doaj.art-b6a980d75b1c47a9ae7d777b0c98483b2024-02-09T15:21:54ZengMDPI AGSensors1424-82202024-01-0124380710.3390/s24030807Validity of the CALERA Research Sensor to Assess Body Core Temperature during Maximum Exercise in Patients with Heart FailureAntonia Kaltsatou0Maria Anifanti1Andreas D. Flouris2Georgia Xiromerisiou3Evangelia Kouidi4FAME Laboratory, Department of Physical Education and Sport Science, University of Thessaly, 42100 Trikala, GreeceSportsmedicine Laboratory, Department of Physical Education and Sport Science, Aristotle University of Thessaloniki, 57000 Thermi, GreeceFAME Laboratory, Department of Physical Education and Sport Science, University of Thessaly, 42100 Trikala, GreeceDepartment of Neurology, University Hospital of Larissa, University of Thessaly, 41110 Larissa, GreeceSportsmedicine Laboratory, Department of Physical Education and Sport Science, Aristotle University of Thessaloniki, 57000 Thermi, Greece(1) Background: It is important to monitor the body core temperature (Tc) of individuals with chronic heart failure (CHF) during rest or exercise, as they are susceptible to complications. Gastrointestinal capsules are a robust indicator of the Tc at rest and during exercise. A practical and non-invasive sensor called CALERA Research was recently introduced, promising accuracy, sensitivity, continuous real-time analysis, repeatability, and reproducibility. This study aimed to assess the validity of the CALERA Research sensor when monitoring patients with CHF during periods of rest, throughout brief cardiopulmonary exercise testing, and during their subsequent recovery. (2) Methods: Twelve male CHF patients volunteered to participate in a 70-min protocol in a laboratory at 28 °C and 39% relative humidity. After remaining calm for 20 min, they underwent a symptom-limited stress test combined with ergospirometry on a treadmill, followed by 40 min of seated recovery. The Tc was continuously monitored by both Tc devices. (3) Results: The Tc values from the CALERA Research sensor and the gastrointestinal sensor showed no associations at rest (r = 0.056, <i>p</i> = 0.154) and during exercise (r = −0.015, <i>p</i> = 0.829) and a weak association during recovery (r = 0.292, <i>p</i> < 0.001). The Cohen’s effect size of the differences between the two Tc assessment methods for rest, exercise, and recovery was 1.04 (large), 0.18 (none), and 0.45 (small), respectively. The 95% limit of agreement for the CALERA Research sensor was −0.057 ± 1.03 °C. (4) Conclusions: The CALERA sensor is a practical and, potentially, promising device, but it does not provide an accurate Tc estimation in CHF patients at rest, during brief exercise testing, and during recovery.https://www.mdpi.com/1424-8220/24/3/807wearable sensorsbody core temperaturechronic heart failurethermoregulation
spellingShingle Antonia Kaltsatou
Maria Anifanti
Andreas D. Flouris
Georgia Xiromerisiou
Evangelia Kouidi
Validity of the CALERA Research Sensor to Assess Body Core Temperature during Maximum Exercise in Patients with Heart Failure
Sensors
wearable sensors
body core temperature
chronic heart failure
thermoregulation
title Validity of the CALERA Research Sensor to Assess Body Core Temperature during Maximum Exercise in Patients with Heart Failure
title_full Validity of the CALERA Research Sensor to Assess Body Core Temperature during Maximum Exercise in Patients with Heart Failure
title_fullStr Validity of the CALERA Research Sensor to Assess Body Core Temperature during Maximum Exercise in Patients with Heart Failure
title_full_unstemmed Validity of the CALERA Research Sensor to Assess Body Core Temperature during Maximum Exercise in Patients with Heart Failure
title_short Validity of the CALERA Research Sensor to Assess Body Core Temperature during Maximum Exercise in Patients with Heart Failure
title_sort validity of the calera research sensor to assess body core temperature during maximum exercise in patients with heart failure
topic wearable sensors
body core temperature
chronic heart failure
thermoregulation
url https://www.mdpi.com/1424-8220/24/3/807
work_keys_str_mv AT antoniakaltsatou validityofthecaleraresearchsensortoassessbodycoretemperatureduringmaximumexerciseinpatientswithheartfailure
AT mariaanifanti validityofthecaleraresearchsensortoassessbodycoretemperatureduringmaximumexerciseinpatientswithheartfailure
AT andreasdflouris validityofthecaleraresearchsensortoassessbodycoretemperatureduringmaximumexerciseinpatientswithheartfailure
AT georgiaxiromerisiou validityofthecaleraresearchsensortoassessbodycoretemperatureduringmaximumexerciseinpatientswithheartfailure
AT evangeliakouidi validityofthecaleraresearchsensortoassessbodycoretemperatureduringmaximumexerciseinpatientswithheartfailure