Spiral Deployment of Optical Fiber Sensors for Distributed Strain Measurement in Seven-Wire Twisted Steel Cables, Post-Tensioned against Precast Concrete Bars

On-time monitoring and condition assessments of steel cables provide mission-critical data for informed decision making, ensuring the structural safety of post-tensioned concrete structures. This study aimed to develop a spiral deployment scheme of distributed fiber optic sensors (DFOS) and to monit...

Full description

Bibliographic Details
Main Authors: Yanping Zhu, Genda Chen
Format: Article
Language:English
Published: MDPI AG 2022-10-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/22/19/7636
_version_ 1797476841327427584
author Yanping Zhu
Genda Chen
author_facet Yanping Zhu
Genda Chen
author_sort Yanping Zhu
collection DOAJ
description On-time monitoring and condition assessments of steel cables provide mission-critical data for informed decision making, ensuring the structural safety of post-tensioned concrete structures. This study aimed to develop a spiral deployment scheme of distributed fiber optic sensors (DFOS) and to monitor/assess the post-tensioned force in seven-wire twisted steel cables, based on the pulse-pre-pump Brillouin optical time domain analysis. Each DFOS was placed in a spiral shape between two surface wires of a steel cable and glued to the steel cable by epoxy. Image observations were conducted to investigate the entireness and bonding condition between the optical fiber and the steel wires. Eight concrete bar specimens were cast, each with a pre-embedded plastic or metal duct at its center and each was post-tensioned by a steel strand through the duct once they were instrumented with two strain and two temperature sensors. The strand was loaded/unloaded and monitored by measuring the Brillouin frequency shifts and correlating them with the applied strains and the resulting cable force after temperature compensation. The maximum, minimum, and average cable forces integrated from the measured stain data were compared and validated with those from a load cell. The maximum (or average) cable force was linearly related to the ground truth data with a less than 10% error between them, after any initial slack had been removed from the test setup. The post-tensioned force loss was bounded by approximately 30%, using the test setup designed in this study.
first_indexed 2024-03-09T21:09:30Z
format Article
id doaj.art-b732780b87854bdb8fef31a20a867b3e
institution Directory Open Access Journal
issn 1424-8220
language English
last_indexed 2024-03-09T21:09:30Z
publishDate 2022-10-01
publisher MDPI AG
record_format Article
series Sensors
spelling doaj.art-b732780b87854bdb8fef31a20a867b3e2023-11-23T21:52:24ZengMDPI AGSensors1424-82202022-10-012219763610.3390/s22197636Spiral Deployment of Optical Fiber Sensors for Distributed Strain Measurement in Seven-Wire Twisted Steel Cables, Post-Tensioned against Precast Concrete BarsYanping Zhu0Genda Chen1Department of Civil, Architectural, and Environmental Engineering, Missouri University of Science and Technology, Rolla, MO 65401, USADepartment of Civil, Architectural, and Environmental Engineering, Missouri University of Science and Technology, Rolla, MO 65401, USAOn-time monitoring and condition assessments of steel cables provide mission-critical data for informed decision making, ensuring the structural safety of post-tensioned concrete structures. This study aimed to develop a spiral deployment scheme of distributed fiber optic sensors (DFOS) and to monitor/assess the post-tensioned force in seven-wire twisted steel cables, based on the pulse-pre-pump Brillouin optical time domain analysis. Each DFOS was placed in a spiral shape between two surface wires of a steel cable and glued to the steel cable by epoxy. Image observations were conducted to investigate the entireness and bonding condition between the optical fiber and the steel wires. Eight concrete bar specimens were cast, each with a pre-embedded plastic or metal duct at its center and each was post-tensioned by a steel strand through the duct once they were instrumented with two strain and two temperature sensors. The strand was loaded/unloaded and monitored by measuring the Brillouin frequency shifts and correlating them with the applied strains and the resulting cable force after temperature compensation. The maximum, minimum, and average cable forces integrated from the measured stain data were compared and validated with those from a load cell. The maximum (or average) cable force was linearly related to the ground truth data with a less than 10% error between them, after any initial slack had been removed from the test setup. The post-tensioned force loss was bounded by approximately 30%, using the test setup designed in this study.https://www.mdpi.com/1424-8220/22/19/7636distributed fiber optic sensorspost-tensioned concrete structurescable forcesprestress losses
spellingShingle Yanping Zhu
Genda Chen
Spiral Deployment of Optical Fiber Sensors for Distributed Strain Measurement in Seven-Wire Twisted Steel Cables, Post-Tensioned against Precast Concrete Bars
Sensors
distributed fiber optic sensors
post-tensioned concrete structures
cable forces
prestress losses
title Spiral Deployment of Optical Fiber Sensors for Distributed Strain Measurement in Seven-Wire Twisted Steel Cables, Post-Tensioned against Precast Concrete Bars
title_full Spiral Deployment of Optical Fiber Sensors for Distributed Strain Measurement in Seven-Wire Twisted Steel Cables, Post-Tensioned against Precast Concrete Bars
title_fullStr Spiral Deployment of Optical Fiber Sensors for Distributed Strain Measurement in Seven-Wire Twisted Steel Cables, Post-Tensioned against Precast Concrete Bars
title_full_unstemmed Spiral Deployment of Optical Fiber Sensors for Distributed Strain Measurement in Seven-Wire Twisted Steel Cables, Post-Tensioned against Precast Concrete Bars
title_short Spiral Deployment of Optical Fiber Sensors for Distributed Strain Measurement in Seven-Wire Twisted Steel Cables, Post-Tensioned against Precast Concrete Bars
title_sort spiral deployment of optical fiber sensors for distributed strain measurement in seven wire twisted steel cables post tensioned against precast concrete bars
topic distributed fiber optic sensors
post-tensioned concrete structures
cable forces
prestress losses
url https://www.mdpi.com/1424-8220/22/19/7636
work_keys_str_mv AT yanpingzhu spiraldeploymentofopticalfibersensorsfordistributedstrainmeasurementinsevenwiretwistedsteelcablesposttensionedagainstprecastconcretebars
AT gendachen spiraldeploymentofopticalfibersensorsfordistributedstrainmeasurementinsevenwiretwistedsteelcablesposttensionedagainstprecastconcretebars