Comparative Performance of DFIG and PMSG Wind Turbines during Transient State in Weak and Strong Grid Conditions Considering Series Dynamic Braking Resistor

The recently stipulated grid codes require wind generators to re-initiate normal power production after grid voltage sag. This paper presents a comparative performance of two commonly employed variable speed wind turbines in today’s electricity market, the doubly fed induction generator (DFIG) and t...

Full description

Bibliographic Details
Main Authors: Kenneth E. Okedu, S. M. Muyeen
Format: Article
Language:English
Published: MDPI AG 2022-12-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/15/23/9228
_version_ 1797463231506153472
author Kenneth E. Okedu
S. M. Muyeen
author_facet Kenneth E. Okedu
S. M. Muyeen
author_sort Kenneth E. Okedu
collection DOAJ
description The recently stipulated grid codes require wind generators to re-initiate normal power production after grid voltage sag. This paper presents a comparative performance of two commonly employed variable speed wind turbines in today’s electricity market, the doubly fed induction generator (DFIG) and the permanent magnet synchronous generator (PMSG) wind turbines. The evaluation of both wind turbines was performed for weak, normal and strong grids, considering the same machine ratings of the wind turbines. Because of the critical situations of the wind turbines during faulty conditions in the weak grids, an analysis was done considering the use of effective series dynamic braking resistor (SDBR) for both wind turbines. The grid voltage variable was employed as the signal for switching the SDBR in both wind turbines during transient state. Additionally, an overvoltage protection system was considered for both wind turbines using the DC chopper in the DC-link excitation circuitry of both wind turbines. Furthermore, a combination of the SDBR over-voltage protection scheme (OVPS) was employed in both wind turbines at weak grid condition in order to improve the performance of the variable speed wind turbines and keep the operation of the power converters within their permissible limits. Furthermore, the performance of the DFIG and PMSG wind turbines in weak grids were further investigated, considering the combination of 75% and 50% effectively sized SDBR and OVPS. It was observed that, even with a 50% reduction in SDBR or OVPS, the performance of both wind turbines is still satisfactory with faulty conditions. Therefore, it is recommended to use a combination of the SDBR and OVPS with DFIG- or PMSG-based variable speed wind turbines to achieve a superior fault ride through performance, especially in weak grids. The system performance was evaluated using the power system computer design and electromagnetic transient including DC (PSCAD/EMTDC) platform.
first_indexed 2024-03-09T17:48:42Z
format Article
id doaj.art-b738e861a47541228c5a920f7b86a7af
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-03-09T17:48:42Z
publishDate 2022-12-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-b738e861a47541228c5a920f7b86a7af2023-11-24T10:57:23ZengMDPI AGEnergies1996-10732022-12-011523922810.3390/en15239228Comparative Performance of DFIG and PMSG Wind Turbines during Transient State in Weak and Strong Grid Conditions Considering Series Dynamic Braking ResistorKenneth E. Okedu0S. M. Muyeen1Department of Electrical and Communication Engineering, National University of Science and Technology, Al Hail, Muscat PC 111, OmanDepartment of Electrical and Electronic Engineering, Qatar University, Doha 2713, QatarThe recently stipulated grid codes require wind generators to re-initiate normal power production after grid voltage sag. This paper presents a comparative performance of two commonly employed variable speed wind turbines in today’s electricity market, the doubly fed induction generator (DFIG) and the permanent magnet synchronous generator (PMSG) wind turbines. The evaluation of both wind turbines was performed for weak, normal and strong grids, considering the same machine ratings of the wind turbines. Because of the critical situations of the wind turbines during faulty conditions in the weak grids, an analysis was done considering the use of effective series dynamic braking resistor (SDBR) for both wind turbines. The grid voltage variable was employed as the signal for switching the SDBR in both wind turbines during transient state. Additionally, an overvoltage protection system was considered for both wind turbines using the DC chopper in the DC-link excitation circuitry of both wind turbines. Furthermore, a combination of the SDBR over-voltage protection scheme (OVPS) was employed in both wind turbines at weak grid condition in order to improve the performance of the variable speed wind turbines and keep the operation of the power converters within their permissible limits. Furthermore, the performance of the DFIG and PMSG wind turbines in weak grids were further investigated, considering the combination of 75% and 50% effectively sized SDBR and OVPS. It was observed that, even with a 50% reduction in SDBR or OVPS, the performance of both wind turbines is still satisfactory with faulty conditions. Therefore, it is recommended to use a combination of the SDBR and OVPS with DFIG- or PMSG-based variable speed wind turbines to achieve a superior fault ride through performance, especially in weak grids. The system performance was evaluated using the power system computer design and electromagnetic transient including DC (PSCAD/EMTDC) platform.https://www.mdpi.com/1996-1073/15/23/9228DFIGPMSGstrong gridswind energyweak grids
spellingShingle Kenneth E. Okedu
S. M. Muyeen
Comparative Performance of DFIG and PMSG Wind Turbines during Transient State in Weak and Strong Grid Conditions Considering Series Dynamic Braking Resistor
Energies
DFIG
PMSG
strong grids
wind energy
weak grids
title Comparative Performance of DFIG and PMSG Wind Turbines during Transient State in Weak and Strong Grid Conditions Considering Series Dynamic Braking Resistor
title_full Comparative Performance of DFIG and PMSG Wind Turbines during Transient State in Weak and Strong Grid Conditions Considering Series Dynamic Braking Resistor
title_fullStr Comparative Performance of DFIG and PMSG Wind Turbines during Transient State in Weak and Strong Grid Conditions Considering Series Dynamic Braking Resistor
title_full_unstemmed Comparative Performance of DFIG and PMSG Wind Turbines during Transient State in Weak and Strong Grid Conditions Considering Series Dynamic Braking Resistor
title_short Comparative Performance of DFIG and PMSG Wind Turbines during Transient State in Weak and Strong Grid Conditions Considering Series Dynamic Braking Resistor
title_sort comparative performance of dfig and pmsg wind turbines during transient state in weak and strong grid conditions considering series dynamic braking resistor
topic DFIG
PMSG
strong grids
wind energy
weak grids
url https://www.mdpi.com/1996-1073/15/23/9228
work_keys_str_mv AT kennetheokedu comparativeperformanceofdfigandpmsgwindturbinesduringtransientstateinweakandstronggridconditionsconsideringseriesdynamicbrakingresistor
AT smmuyeen comparativeperformanceofdfigandpmsgwindturbinesduringtransientstateinweakandstronggridconditionsconsideringseriesdynamicbrakingresistor