Study of heat shielding qualities of brick wall angle with additional insulation located on the outside fences

The results of theoretical studies of heat-shielding properties of the angle of external wall a residential building are presented. The brick wall thickness of 510 mm was considered. The studies were performed for the I-st temperature zone of Ukraine. Heat insulation was located on the external side...

Full description

Bibliographic Details
Main Authors: Yurin Oleg, Galinska Tatiana
Format: Article
Language:English
Published: EDP Sciences 2017-01-01
Series:MATEC Web of Conferences
Online Access:https://doi.org/10.1051/matecconf/201711602039
_version_ 1818368189448323072
author Yurin Oleg
Galinska Tatiana
author_facet Yurin Oleg
Galinska Tatiana
author_sort Yurin Oleg
collection DOAJ
description The results of theoretical studies of heat-shielding properties of the angle of external wall a residential building are presented. The brick wall thickness of 510 mm was considered. The studies were performed for the I-st temperature zone of Ukraine. Heat insulation was located on the external side of enclosure. Thermal protection problems of the angle are consideration of the impact of heat-conductive inclusion on adjusted heat transfer resistance of enclosure. Conductive inclusion on the external angle area is its configuration. An additional layer of insulation in the angle area is necessary to use for bringing the level of thermal protection of angle area to the standards. The results of calculations of two-dimensional temperature fields were used for the analysis of thermal protection. Two options for additional insulation were studied. The first option: continuous strip insulation covering the external wall angle. Another one provides division of additional insulation layer into two parts and displacement them from the angle within the design scheme. Studies were performed for different thickness of additional insulation. There was additionally taking into account the value of insulation displacement from the angle for the second option. The optimal location and size of additional insulation were determined. The minimum amount of additional insulation under which the thermal protection requirements are performed was accepted like optimality criterion.
first_indexed 2024-12-13T23:04:00Z
format Article
id doaj.art-b74ac5bfde5f4b2387ce2903a4a3ff47
institution Directory Open Access Journal
issn 2261-236X
language English
last_indexed 2024-12-13T23:04:00Z
publishDate 2017-01-01
publisher EDP Sciences
record_format Article
series MATEC Web of Conferences
spelling doaj.art-b74ac5bfde5f4b2387ce2903a4a3ff472022-12-21T23:28:20ZengEDP SciencesMATEC Web of Conferences2261-236X2017-01-011160203910.1051/matecconf/201711602039matecconf_trs2017_02039Study of heat shielding qualities of brick wall angle with additional insulation located on the outside fencesYurin Oleg0Galinska Tatiana1Poltava National Technical Yuri Kondratyuk University, Department of Civil EngineeringPoltava National Technical Yuri Kondratyuk University, Department of Civil EngineeringThe results of theoretical studies of heat-shielding properties of the angle of external wall a residential building are presented. The brick wall thickness of 510 mm was considered. The studies were performed for the I-st temperature zone of Ukraine. Heat insulation was located on the external side of enclosure. Thermal protection problems of the angle are consideration of the impact of heat-conductive inclusion on adjusted heat transfer resistance of enclosure. Conductive inclusion on the external angle area is its configuration. An additional layer of insulation in the angle area is necessary to use for bringing the level of thermal protection of angle area to the standards. The results of calculations of two-dimensional temperature fields were used for the analysis of thermal protection. Two options for additional insulation were studied. The first option: continuous strip insulation covering the external wall angle. Another one provides division of additional insulation layer into two parts and displacement them from the angle within the design scheme. Studies were performed for different thickness of additional insulation. There was additionally taking into account the value of insulation displacement from the angle for the second option. The optimal location and size of additional insulation were determined. The minimum amount of additional insulation under which the thermal protection requirements are performed was accepted like optimality criterion.https://doi.org/10.1051/matecconf/201711602039
spellingShingle Yurin Oleg
Galinska Tatiana
Study of heat shielding qualities of brick wall angle with additional insulation located on the outside fences
MATEC Web of Conferences
title Study of heat shielding qualities of brick wall angle with additional insulation located on the outside fences
title_full Study of heat shielding qualities of brick wall angle with additional insulation located on the outside fences
title_fullStr Study of heat shielding qualities of brick wall angle with additional insulation located on the outside fences
title_full_unstemmed Study of heat shielding qualities of brick wall angle with additional insulation located on the outside fences
title_short Study of heat shielding qualities of brick wall angle with additional insulation located on the outside fences
title_sort study of heat shielding qualities of brick wall angle with additional insulation located on the outside fences
url https://doi.org/10.1051/matecconf/201711602039
work_keys_str_mv AT yurinoleg studyofheatshieldingqualitiesofbrickwallanglewithadditionalinsulationlocatedontheoutsidefences
AT galinskatatiana studyofheatshieldingqualitiesofbrickwallanglewithadditionalinsulationlocatedontheoutsidefences