Nylon Membrane-Based Electromembrane Extraction Coupled with Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry for the Determination of Insulin
A rapid and sensitive protein determination method that uses electromembrane extraction (EME) and is coupled with matrix-assisted laser desorption/ionization mass spectrometry (MALDI/MS) is developed. A flat nylon membrane is used to collect proteins from an aqueous solution and is directly analyzed...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2022-10-01
|
Series: | Separations |
Subjects: | |
Online Access: | https://www.mdpi.com/2297-8739/9/10/286 |
_version_ | 1797469938736168960 |
---|---|
author | Jun-Kai Huang Yi-Wen Hsiao Wen-Chi Chen Sarah Y. Chang |
author_facet | Jun-Kai Huang Yi-Wen Hsiao Wen-Chi Chen Sarah Y. Chang |
author_sort | Jun-Kai Huang |
collection | DOAJ |
description | A rapid and sensitive protein determination method that uses electromembrane extraction (EME) and is coupled with matrix-assisted laser desorption/ionization mass spectrometry (MALDI/MS) is developed. A flat nylon membrane is used to collect proteins from an aqueous solution and is directly analyzed by MALDI/MS after the addition of the MALDI matrix. Insulin is used as a model protein to investigate the optimum extraction of the parameters. The optimum EME conditions are obtained at 12 V of voltage, 10 min of extraction time, 12 mL sample volume, and 400 rpm agitation rate. The linear dynamic range (LDR) of insulin in an aqueous solution is in the range of 1.0–100.0 nM. The limit of detection (LOD) for insulin in an aqueous solution is 0.3 nM with 103-fold signal-to-noise (S/N) ratio enhancement. Furthermore, the applicability of this method to determine insulin in complicated sample matrices is also investigated. The LDR of insulin in human urine samples is in the range of 5.0–100.0 nM, and the LOD of insulin in urine samples is calculated to be 1.5 nM. The precision and accuracy of this method are evaluated at three different concentration levels, and the coefficient of variation (CV) and relative error are less than 6%. This approach is time-efficient and economical, as the flat membrane mode of EME coupled with MALDI/MS is suitable. |
first_indexed | 2024-03-09T19:30:01Z |
format | Article |
id | doaj.art-b7b73cb507a54fb3be7abf65271a53de |
institution | Directory Open Access Journal |
issn | 2297-8739 |
language | English |
last_indexed | 2024-03-09T19:30:01Z |
publishDate | 2022-10-01 |
publisher | MDPI AG |
record_format | Article |
series | Separations |
spelling | doaj.art-b7b73cb507a54fb3be7abf65271a53de2023-11-24T02:32:11ZengMDPI AGSeparations2297-87392022-10-0191028610.3390/separations9100286Nylon Membrane-Based Electromembrane Extraction Coupled with Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry for the Determination of InsulinJun-Kai Huang0Yi-Wen Hsiao1Wen-Chi Chen2Sarah Y. Chang3Department of Chemistry, National Kaohsiung Normal University, Yanchao, Kaohsiung 824, TaiwanDepartment of Chemistry, National Kaohsiung Normal University, Yanchao, Kaohsiung 824, TaiwanDivision of Gastroenterology and Hepatology, Department of Medicine, Kaohsiung Veterans General Hospital, Kaohsiung 813, TaiwanDepartment of Chemistry, National Kaohsiung Normal University, Yanchao, Kaohsiung 824, TaiwanA rapid and sensitive protein determination method that uses electromembrane extraction (EME) and is coupled with matrix-assisted laser desorption/ionization mass spectrometry (MALDI/MS) is developed. A flat nylon membrane is used to collect proteins from an aqueous solution and is directly analyzed by MALDI/MS after the addition of the MALDI matrix. Insulin is used as a model protein to investigate the optimum extraction of the parameters. The optimum EME conditions are obtained at 12 V of voltage, 10 min of extraction time, 12 mL sample volume, and 400 rpm agitation rate. The linear dynamic range (LDR) of insulin in an aqueous solution is in the range of 1.0–100.0 nM. The limit of detection (LOD) for insulin in an aqueous solution is 0.3 nM with 103-fold signal-to-noise (S/N) ratio enhancement. Furthermore, the applicability of this method to determine insulin in complicated sample matrices is also investigated. The LDR of insulin in human urine samples is in the range of 5.0–100.0 nM, and the LOD of insulin in urine samples is calculated to be 1.5 nM. The precision and accuracy of this method are evaluated at three different concentration levels, and the coefficient of variation (CV) and relative error are less than 6%. This approach is time-efficient and economical, as the flat membrane mode of EME coupled with MALDI/MS is suitable.https://www.mdpi.com/2297-8739/9/10/286electromembrane extractionmatrix-assisted laser desorption/ionization mass spectrometryproteinsinsulin |
spellingShingle | Jun-Kai Huang Yi-Wen Hsiao Wen-Chi Chen Sarah Y. Chang Nylon Membrane-Based Electromembrane Extraction Coupled with Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry for the Determination of Insulin Separations electromembrane extraction matrix-assisted laser desorption/ionization mass spectrometry proteins insulin |
title | Nylon Membrane-Based Electromembrane Extraction Coupled with Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry for the Determination of Insulin |
title_full | Nylon Membrane-Based Electromembrane Extraction Coupled with Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry for the Determination of Insulin |
title_fullStr | Nylon Membrane-Based Electromembrane Extraction Coupled with Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry for the Determination of Insulin |
title_full_unstemmed | Nylon Membrane-Based Electromembrane Extraction Coupled with Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry for the Determination of Insulin |
title_short | Nylon Membrane-Based Electromembrane Extraction Coupled with Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry for the Determination of Insulin |
title_sort | nylon membrane based electromembrane extraction coupled with matrix assisted laser desorption ionization mass spectrometry for the determination of insulin |
topic | electromembrane extraction matrix-assisted laser desorption/ionization mass spectrometry proteins insulin |
url | https://www.mdpi.com/2297-8739/9/10/286 |
work_keys_str_mv | AT junkaihuang nylonmembranebasedelectromembraneextractioncoupledwithmatrixassistedlaserdesorptionionizationmassspectrometryforthedeterminationofinsulin AT yiwenhsiao nylonmembranebasedelectromembraneextractioncoupledwithmatrixassistedlaserdesorptionionizationmassspectrometryforthedeterminationofinsulin AT wenchichen nylonmembranebasedelectromembraneextractioncoupledwithmatrixassistedlaserdesorptionionizationmassspectrometryforthedeterminationofinsulin AT sarahychang nylonmembranebasedelectromembraneextractioncoupledwithmatrixassistedlaserdesorptionionizationmassspectrometryforthedeterminationofinsulin |