Cold Atmospheric Pressure Plasma Jet Operated in Ar and He: From Basic Plasma Properties to Vacuum Ultraviolet, Electric Field and Safety Thresholds Measurements in Plasma Medicine

Application desired functionality as well as operation expenses of cold atmospheric pressure plasma (CAP) devices scale with properties like gas selection. The present contribution provides a comparative investigation for a CAP system operated in argon or helium at different operation voltages and d...

Full description

Bibliographic Details
Main Authors: Andrei Vasile Nastuta, Torsten Gerling
Format: Article
Language:English
Published: MDPI AG 2022-01-01
Series:Applied Sciences
Subjects:
Online Access:https://www.mdpi.com/2076-3417/12/2/644
_version_ 1827666902493691904
author Andrei Vasile Nastuta
Torsten Gerling
author_facet Andrei Vasile Nastuta
Torsten Gerling
author_sort Andrei Vasile Nastuta
collection DOAJ
description Application desired functionality as well as operation expenses of cold atmospheric pressure plasma (CAP) devices scale with properties like gas selection. The present contribution provides a comparative investigation for a CAP system operated in argon or helium at different operation voltages and distance to the surface. Comparison of power dissipation, electrical field strength and optical emission spectroscopy from vacuum ultraviolet over visible up to near infrared ((V)UV-VIS-NIR) spectral range is carried out. This study is extended to safety relevant investigation of patient leakage current, induced surface temperature and species density for ozone (O<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msub><mrow></mrow><mn>3</mn></msub></semantics></math></inline-formula>) and nitrogen oxides (NO<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msub><mrow></mrow><mi>x</mi></msub></semantics></math></inline-formula>). It is found that in identical operation conditions (applied voltage, distance to surface and gas flow rate) the dissipated plasma power is about equal (up to 10 W), but the electrical field strength differs, having peak values of 320 kV/m for Ar and up to 300 kV/m for He. However, only for Ar CAP could we measure O<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msub><mrow></mrow><mn>3</mn></msub></semantics></math></inline-formula> up to 2 ppm and NO<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msub><mrow></mrow><mi>x</mi></msub></semantics></math></inline-formula> up to 7 ppm. The surface temperature and leakage values of both systems showed different slopes, with the biggest surprise being a constant leakage current over distance for argon. These findings may open a new direction in the plasma source development for Plasma Medicine.
first_indexed 2024-03-10T01:59:09Z
format Article
id doaj.art-b828f2cafe3f44808713c655e0f52e7c
institution Directory Open Access Journal
issn 2076-3417
language English
last_indexed 2024-03-10T01:59:09Z
publishDate 2022-01-01
publisher MDPI AG
record_format Article
series Applied Sciences
spelling doaj.art-b828f2cafe3f44808713c655e0f52e7c2023-11-23T12:50:25ZengMDPI AGApplied Sciences2076-34172022-01-0112264410.3390/app12020644Cold Atmospheric Pressure Plasma Jet Operated in Ar and He: From Basic Plasma Properties to Vacuum Ultraviolet, Electric Field and Safety Thresholds Measurements in Plasma MedicineAndrei Vasile Nastuta0Torsten Gerling1Physics and Biophysics Education Research Laboratory (P&B-EduResLab), Biomedical Science Department, Faculty of Medical Bioengineering, ‘Grigore T. Popa’ University of Medicine and Pharmacy Iasi, Str. M. Kogalniceanu No. 9-13, 700454 Iasi, RomaniaZIK <i>plasmatis</i>, Leibniz Institute for Plasma Science and Technology (INP), Felix-Hausdorff-Str. 2, 17489 Greifswald, GermanyApplication desired functionality as well as operation expenses of cold atmospheric pressure plasma (CAP) devices scale with properties like gas selection. The present contribution provides a comparative investigation for a CAP system operated in argon or helium at different operation voltages and distance to the surface. Comparison of power dissipation, electrical field strength and optical emission spectroscopy from vacuum ultraviolet over visible up to near infrared ((V)UV-VIS-NIR) spectral range is carried out. This study is extended to safety relevant investigation of patient leakage current, induced surface temperature and species density for ozone (O<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msub><mrow></mrow><mn>3</mn></msub></semantics></math></inline-formula>) and nitrogen oxides (NO<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msub><mrow></mrow><mi>x</mi></msub></semantics></math></inline-formula>). It is found that in identical operation conditions (applied voltage, distance to surface and gas flow rate) the dissipated plasma power is about equal (up to 10 W), but the electrical field strength differs, having peak values of 320 kV/m for Ar and up to 300 kV/m for He. However, only for Ar CAP could we measure O<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msub><mrow></mrow><mn>3</mn></msub></semantics></math></inline-formula> up to 2 ppm and NO<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msub><mrow></mrow><mi>x</mi></msub></semantics></math></inline-formula> up to 7 ppm. The surface temperature and leakage values of both systems showed different slopes, with the biggest surprise being a constant leakage current over distance for argon. These findings may open a new direction in the plasma source development for Plasma Medicine.https://www.mdpi.com/2076-3417/12/2/644CAPelectric diagnosisE-field measurementsvacuum-ultraviolet spectroscopypatient leakage currentpower measurement
spellingShingle Andrei Vasile Nastuta
Torsten Gerling
Cold Atmospheric Pressure Plasma Jet Operated in Ar and He: From Basic Plasma Properties to Vacuum Ultraviolet, Electric Field and Safety Thresholds Measurements in Plasma Medicine
Applied Sciences
CAP
electric diagnosis
E-field measurements
vacuum-ultraviolet spectroscopy
patient leakage current
power measurement
title Cold Atmospheric Pressure Plasma Jet Operated in Ar and He: From Basic Plasma Properties to Vacuum Ultraviolet, Electric Field and Safety Thresholds Measurements in Plasma Medicine
title_full Cold Atmospheric Pressure Plasma Jet Operated in Ar and He: From Basic Plasma Properties to Vacuum Ultraviolet, Electric Field and Safety Thresholds Measurements in Plasma Medicine
title_fullStr Cold Atmospheric Pressure Plasma Jet Operated in Ar and He: From Basic Plasma Properties to Vacuum Ultraviolet, Electric Field and Safety Thresholds Measurements in Plasma Medicine
title_full_unstemmed Cold Atmospheric Pressure Plasma Jet Operated in Ar and He: From Basic Plasma Properties to Vacuum Ultraviolet, Electric Field and Safety Thresholds Measurements in Plasma Medicine
title_short Cold Atmospheric Pressure Plasma Jet Operated in Ar and He: From Basic Plasma Properties to Vacuum Ultraviolet, Electric Field and Safety Thresholds Measurements in Plasma Medicine
title_sort cold atmospheric pressure plasma jet operated in ar and he from basic plasma properties to vacuum ultraviolet electric field and safety thresholds measurements in plasma medicine
topic CAP
electric diagnosis
E-field measurements
vacuum-ultraviolet spectroscopy
patient leakage current
power measurement
url https://www.mdpi.com/2076-3417/12/2/644
work_keys_str_mv AT andreivasilenastuta coldatmosphericpressureplasmajetoperatedinarandhefrombasicplasmapropertiestovacuumultravioletelectricfieldandsafetythresholdsmeasurementsinplasmamedicine
AT torstengerling coldatmosphericpressureplasmajetoperatedinarandhefrombasicplasmapropertiestovacuumultravioletelectricfieldandsafetythresholdsmeasurementsinplasmamedicine