The USER Study: A Chart Review of Patients Receiving a 0.2 µg/day Fluocinolone Acetonide Implant for Diabetic Macular Edema

Abstract Introduction To determine anatomical, functional, and intraocular pressure (IOP) responses to diabetic macular edema (DME) treatments pre- and post-0.2 µg/day fluocinolone acetonide (FAc) implant administration compared with baseline and the preceding 3 years. Methods This was a retrospecti...

Full description

Bibliographic Details
Main Authors: Alexander Eaton, Sean S. Koh, Jaime Jimenez, Christopher D. Riemann
Format: Article
Language:English
Published: Adis, Springer Healthcare 2018-12-01
Series:Ophthalmology and Therapy
Subjects:
Online Access:http://link.springer.com/article/10.1007/s40123-018-0155-5
_version_ 1830414445164101632
author Alexander Eaton
Sean S. Koh
Jaime Jimenez
Christopher D. Riemann
author_facet Alexander Eaton
Sean S. Koh
Jaime Jimenez
Christopher D. Riemann
author_sort Alexander Eaton
collection DOAJ
description Abstract Introduction To determine anatomical, functional, and intraocular pressure (IOP) responses to diabetic macular edema (DME) treatments pre- and post-0.2 µg/day fluocinolone acetonide (FAc) implant administration compared with baseline and the preceding 3 years. Methods This was a retrospective, chart review, cohort study in four U.S. centers. Patients received the 0.2 µg/day FAc implant for the treatment of DME in at least one eye before January 1, 2016. DME treatments administered up to 36 months pre-FAc implant and up to 24 months post-FAc implant were recorded, and treatment frequency was calculated. Visual acuity (VA) was assessed using a Snellen eye chart and converted to early treatment diabetic retinopathy study (ETDRS) letters, and central subfield thickness (CST) was measured using optical coherence tomography (OCT). Treatment frequency, mean VA, mean CST, percentage of patients with CST of ≤ 300 µm, mean IOP, IOP events, and IOP treatments pre- and post-FAc implant administration were measured. Positive and negative predictive values for the IOP response to prior steroid therapy were also determined. Results In total, 160 eyes of 130 patients were studied. VA was maintained at pre-FAc levels from baseline to month 24, despite a significant reduction in treatment frequency from one treatment every 2.9 months pre-FAc implant to one treatment every 14.3 months post-FAc implant. Patients with better baseline VA required fewer DME treatments post-FAc than did patients with worse baseline VA. The majority of patients did not require additional DME treatment during the post-FAc follow-up period. A significant reduction in CST and an increase in the percentage of patients with CST of ≤ 300 µm were seen up to month 21 post-FAc implant. Pre-FAc implant IOP was maintained during the post-FAc implant period; increased IOP with prior steroid therapy was found to be highly predictive of increased IOP post-FAc implant. Conclusion The results of this study confirm the positive safety and efficacy profile of the FAc implant and demonstrate for the first time the effectiveness of the U.S. label indication of FAc in reducing the incidence of post-treatment pressure elevation. The FAc implant significantly reduced treatment burden in the overall population without significantly increasing the risk of steroid-induced pressure elevation. Funding Alimera Sciences.
first_indexed 2024-12-20T20:45:10Z
format Article
id doaj.art-b839cf5cf6b9449daae98bcf56fbf6c4
institution Directory Open Access Journal
issn 2193-8245
2193-6528
language English
last_indexed 2024-12-20T20:45:10Z
publishDate 2018-12-01
publisher Adis, Springer Healthcare
record_format Article
series Ophthalmology and Therapy
spelling doaj.art-b839cf5cf6b9449daae98bcf56fbf6c42022-12-21T19:27:03ZengAdis, Springer HealthcareOphthalmology and Therapy2193-82452193-65282018-12-0181516210.1007/s40123-018-0155-5The USER Study: A Chart Review of Patients Receiving a 0.2 µg/day Fluocinolone Acetonide Implant for Diabetic Macular EdemaAlexander Eaton0Sean S. Koh1Jaime Jimenez2Christopher D. Riemann3Retina Health CenterGeorgia RetinaSouthern Eye CenterCincinnati Eye InstituteAbstract Introduction To determine anatomical, functional, and intraocular pressure (IOP) responses to diabetic macular edema (DME) treatments pre- and post-0.2 µg/day fluocinolone acetonide (FAc) implant administration compared with baseline and the preceding 3 years. Methods This was a retrospective, chart review, cohort study in four U.S. centers. Patients received the 0.2 µg/day FAc implant for the treatment of DME in at least one eye before January 1, 2016. DME treatments administered up to 36 months pre-FAc implant and up to 24 months post-FAc implant were recorded, and treatment frequency was calculated. Visual acuity (VA) was assessed using a Snellen eye chart and converted to early treatment diabetic retinopathy study (ETDRS) letters, and central subfield thickness (CST) was measured using optical coherence tomography (OCT). Treatment frequency, mean VA, mean CST, percentage of patients with CST of ≤ 300 µm, mean IOP, IOP events, and IOP treatments pre- and post-FAc implant administration were measured. Positive and negative predictive values for the IOP response to prior steroid therapy were also determined. Results In total, 160 eyes of 130 patients were studied. VA was maintained at pre-FAc levels from baseline to month 24, despite a significant reduction in treatment frequency from one treatment every 2.9 months pre-FAc implant to one treatment every 14.3 months post-FAc implant. Patients with better baseline VA required fewer DME treatments post-FAc than did patients with worse baseline VA. The majority of patients did not require additional DME treatment during the post-FAc follow-up period. A significant reduction in CST and an increase in the percentage of patients with CST of ≤ 300 µm were seen up to month 21 post-FAc implant. Pre-FAc implant IOP was maintained during the post-FAc implant period; increased IOP with prior steroid therapy was found to be highly predictive of increased IOP post-FAc implant. Conclusion The results of this study confirm the positive safety and efficacy profile of the FAc implant and demonstrate for the first time the effectiveness of the U.S. label indication of FAc in reducing the incidence of post-treatment pressure elevation. The FAc implant significantly reduced treatment burden in the overall population without significantly increasing the risk of steroid-induced pressure elevation. Funding Alimera Sciences.http://link.springer.com/article/10.1007/s40123-018-0155-5Diabetic macular edemaFluocinolone acetonideIntravitreal corticosteroidIntravitreal implantTreatment burdenTreatment frequency
spellingShingle Alexander Eaton
Sean S. Koh
Jaime Jimenez
Christopher D. Riemann
The USER Study: A Chart Review of Patients Receiving a 0.2 µg/day Fluocinolone Acetonide Implant for Diabetic Macular Edema
Ophthalmology and Therapy
Diabetic macular edema
Fluocinolone acetonide
Intravitreal corticosteroid
Intravitreal implant
Treatment burden
Treatment frequency
title The USER Study: A Chart Review of Patients Receiving a 0.2 µg/day Fluocinolone Acetonide Implant for Diabetic Macular Edema
title_full The USER Study: A Chart Review of Patients Receiving a 0.2 µg/day Fluocinolone Acetonide Implant for Diabetic Macular Edema
title_fullStr The USER Study: A Chart Review of Patients Receiving a 0.2 µg/day Fluocinolone Acetonide Implant for Diabetic Macular Edema
title_full_unstemmed The USER Study: A Chart Review of Patients Receiving a 0.2 µg/day Fluocinolone Acetonide Implant for Diabetic Macular Edema
title_short The USER Study: A Chart Review of Patients Receiving a 0.2 µg/day Fluocinolone Acetonide Implant for Diabetic Macular Edema
title_sort user study a chart review of patients receiving a 0 2 µg day fluocinolone acetonide implant for diabetic macular edema
topic Diabetic macular edema
Fluocinolone acetonide
Intravitreal corticosteroid
Intravitreal implant
Treatment burden
Treatment frequency
url http://link.springer.com/article/10.1007/s40123-018-0155-5
work_keys_str_mv AT alexandereaton theuserstudyachartreviewofpatientsreceivinga02μgdayfluocinoloneacetonideimplantfordiabeticmacularedema
AT seanskoh theuserstudyachartreviewofpatientsreceivinga02μgdayfluocinoloneacetonideimplantfordiabeticmacularedema
AT jaimejimenez theuserstudyachartreviewofpatientsreceivinga02μgdayfluocinoloneacetonideimplantfordiabeticmacularedema
AT christopherdriemann theuserstudyachartreviewofpatientsreceivinga02μgdayfluocinoloneacetonideimplantfordiabeticmacularedema
AT alexandereaton userstudyachartreviewofpatientsreceivinga02μgdayfluocinoloneacetonideimplantfordiabeticmacularedema
AT seanskoh userstudyachartreviewofpatientsreceivinga02μgdayfluocinoloneacetonideimplantfordiabeticmacularedema
AT jaimejimenez userstudyachartreviewofpatientsreceivinga02μgdayfluocinoloneacetonideimplantfordiabeticmacularedema
AT christopherdriemann userstudyachartreviewofpatientsreceivinga02μgdayfluocinoloneacetonideimplantfordiabeticmacularedema