Accuracy of Patient-Specific Drilling Guides in Acetabular Fracture Surgery: A Human Cadaver Study
Due to the complex anatomical shape of the pelvis, screw placement can be challenging in acetabular fracture surgery. This study aims to assess the accuracy of screw placement using patient-specific surgical drilling guides applied to pre-contoured conventional implants in acetabular fracture surger...
Main Authors: | Anne M. L. Meesters, Nick Assink, Kaj ten Duis, Eelco M. Fennema, Joep Kraeima, Max J. H. Witjes, Jean-Paul P. M. de Vries, Vincent M. A. Stirler, Frank F. A. IJpma |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-08-01
|
Series: | Journal of Personalized Medicine |
Subjects: | |
Online Access: | https://www.mdpi.com/2075-4426/11/8/763 |
Similar Items
-
Does 3D-Assisted Acetabular Fracture Surgery Improve Surgical Outcome and Physical Functioning?—A Systematic Review
by: Anne M. L. Meesters, et al.
Published: (2021-09-01) -
Quantitative Three-Dimensional Measurements of Acetabular Fracture Displacement Could Be Predictive for Native Hip Survivorship
by: Anne M. L. Meesters, et al.
Published: (2022-09-01) -
Both-Column Acetabular Fractures: Does Surgical Approach Vary Based on Using Virtual 3D Reconstructions?
by: Judith F. Leemhuis, et al.
Published: (2023-05-01) -
3D surgical planning including patient-specific drilling guides for tibial plateau fractures: a prospective feasibility study
by: Nick Assink, et al.
Published: (2024-01-01) -
A Two-Step Approach for 3D-Guided Patient-Specific Corrective Limb Osteotomies
by: Nick Assink, et al.
Published: (2022-09-01)