Microstructure, mechanical property and corrosion behavior of porous Ti–Ta–Nb–Zr
In this paper, biomedical porous Ti–Nb–Ta–Zr with 40% porosity and 166 ± 21 μm macro-pore size was successfully fabricated by space holder method. The microstructure, Vickers hardness, compressive and electrochemistry behavior were studied. It results that a few second phases exist in β matrix of th...
Main Authors: | B.Q. Li, R.Z. Xie, X. Lu |
---|---|
Format: | Article |
Language: | English |
Published: |
KeAi Communications Co., Ltd.
2020-09-01
|
Series: | Bioactive Materials |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2452199X20300748 |