Successful removal of an intra-pericardic Kirschner wire via fluoroscopy-guided minimal invasive approach: a case report

Abstract Background Kirschner wires are widely used in trauma surgery. Their migration into the pericardium is a rare but often fatal phenomenon, requiring urgent management. Case presentation We describe the case of a 65-year-old patient who underwent Kirschner wire placement to treat a humeral hea...

Full description

Bibliographic Details
Main Authors: Olivier Georges, Florence De Dominicis, Malek Ben Rahal, Jules Le Pessot, Pascal Berna, Osama Abou Arab, Christophe Beyls
Format: Article
Language:English
Published: SpringerOpen 2024-03-01
Series:Surgical Case Reports
Subjects:
Online Access:https://doi.org/10.1186/s40792-023-01803-8
Description
Summary:Abstract Background Kirschner wires are widely used in trauma surgery. Their migration into the pericardium is a rare but often fatal phenomenon, requiring urgent management. Case presentation We describe the case of a 65-year-old patient who underwent Kirschner wire placement to treat a humeral head fracture. Three months after the operation, pleural and pericardial effusions with cardiac tamponade were observed, leading to the diagnosis of wire migration within the pericardium. A minimally invasive approach guided by fluoroscopy allowed emergency wire extraction without needing a median sternotomy. The postoperative clinical course was uncomplicated. Conclusions The use of pre- and per-operative multimodal imaging allowed for the safe extraction of an intra-pericardial Kirschner wire through a minimally invasive approach.