Estimation to Practicability of the Building Substation by Voltage 330 sQ with Three Power Transformers
It is installed that hooking two lines and two transformers at scheme distributing device by voltage 330 sQ «transformers – a buses with joining line through two breakers» and three installed transformer on substations brings about reduction of the factor to unavailability in 18,2 times in contrast...
Main Authors: | , |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Belarusian National Technical University
2012-12-01
|
Series: | Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika |
Online Access: | https://energy.bntu.by/jour/article/view/180 |
_version_ | 1797879834965180416 |
---|---|
author | M. A. Korotkevich A. L. Starzhinsky |
author_facet | M. A. Korotkevich A. L. Starzhinsky |
author_sort | M. A. Korotkevich |
collection | DOAJ |
description | It is installed that hooking two lines and two transformers at scheme distributing device by voltage 330 sQ «transformers – a buses with joining line through two breakers» and three installed transformer on substations brings about reduction of the factor to unavailability in 18,2 times in contrast with scheme with two transformers. At connection of the third transformer through two breakers factor to unavailability practically does not change.At connection one of the transformer through two breakers, at one-and-a-half-breaker scheme RU 330 sQ factor to unavailability falls in 6,6 times to scheme RU 330 sQ «transformers – a buses with joining line through two breakers» under three transformers. |
first_indexed | 2024-04-10T02:55:07Z |
format | Article |
id | doaj.art-b91a30daa0cb485090915a10dd022913 |
institution | Directory Open Access Journal |
issn | 1029-7448 2414-0341 |
language | Russian |
last_indexed | 2024-04-10T02:55:07Z |
publishDate | 2012-12-01 |
publisher | Belarusian National Technical University |
record_format | Article |
series | Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika |
spelling | doaj.art-b91a30daa0cb485090915a10dd0229132023-03-13T07:41:48ZrusBelarusian National Technical UniversityIzvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika1029-74482414-03412012-12-0106174Estimation to Practicability of the Building Substation by Voltage 330 sQ with Three Power TransformersM. A. Korotkevich0A. L. Starzhinsky1Белорусский национальный технический университетБелорусский национальный технический университетIt is installed that hooking two lines and two transformers at scheme distributing device by voltage 330 sQ «transformers – a buses with joining line through two breakers» and three installed transformer on substations brings about reduction of the factor to unavailability in 18,2 times in contrast with scheme with two transformers. At connection of the third transformer through two breakers factor to unavailability practically does not change.At connection one of the transformer through two breakers, at one-and-a-half-breaker scheme RU 330 sQ factor to unavailability falls in 6,6 times to scheme RU 330 sQ «transformers – a buses with joining line through two breakers» under three transformers.https://energy.bntu.by/jour/article/view/180 |
spellingShingle | M. A. Korotkevich A. L. Starzhinsky Estimation to Practicability of the Building Substation by Voltage 330 sQ with Three Power Transformers Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika |
title | Estimation to Practicability of the Building Substation by Voltage 330 sQ with Three Power Transformers |
title_full | Estimation to Practicability of the Building Substation by Voltage 330 sQ with Three Power Transformers |
title_fullStr | Estimation to Practicability of the Building Substation by Voltage 330 sQ with Three Power Transformers |
title_full_unstemmed | Estimation to Practicability of the Building Substation by Voltage 330 sQ with Three Power Transformers |
title_short | Estimation to Practicability of the Building Substation by Voltage 330 sQ with Three Power Transformers |
title_sort | estimation to practicability of the building substation by voltage 330 sq with three power transformers |
url | https://energy.bntu.by/jour/article/view/180 |
work_keys_str_mv | AT makorotkevich estimationtopracticabilityofthebuildingsubstationbyvoltage330sqwiththreepowertransformers AT alstarzhinsky estimationtopracticabilityofthebuildingsubstationbyvoltage330sqwiththreepowertransformers |