Patient Specific Instrumentation and Total Ankle Arthroplasty

Category: Ankle Arthritis; Ankle Introduction/Purpose: Total Ankle Arthroplasty (TAA) can now be performed using Patient Specific Instrumentation (PSI). Advantages include the ability to pre-operatively plan bone resections and implant position and reduce the number of intra- operative surgical step...

Full description

Bibliographic Details
Main Authors: James K. Yau, An Murty, Rajesh Kakwani, David N. Townshend MBBS, FRCS(Tr&Orth)
Format: Article
Language:English
Published: SAGE Publishing 2022-11-01
Series:Foot & Ankle Orthopaedics
Online Access:https://doi.org/10.1177/2473011421S01012
_version_ 1811217038279966720
author James K. Yau
An Murty
Rajesh Kakwani
David N. Townshend MBBS, FRCS(Tr&Orth)
author_facet James K. Yau
An Murty
Rajesh Kakwani
David N. Townshend MBBS, FRCS(Tr&Orth)
author_sort James K. Yau
collection DOAJ
description Category: Ankle Arthritis; Ankle Introduction/Purpose: Total Ankle Arthroplasty (TAA) can now be performed using Patient Specific Instrumentation (PSI). Advantages include the ability to pre-operatively plan bone resections and implant position and reduce the number of intra- operative surgical steps. The aim of this study was to compare PSI with Standard Instrumentation (SI) in a non-randomised retrospective cohort study with respect to patient reported outcomes, tourniquet time, fluoroscopy time and post-operative alignment. Methods: 159 patients (111 male, 48 female) undergoing a total of 168 INFINITY TAA using PSI (Prophecy, Wright Medical Technology) or SI between 2014 and 2020 were included with a minimum follow up of 12 months. Patient reported outcome measures (PROMS) were obtained pre-operatively and at one year and included the Manchester-Oxford Foot Questionnaire (MOXFQ), Ankle Osteoarthritis Scale (AOS) and EQ-5D Index. Coronal plane deformity correction was assessed using the midline tibiotalar angle (MTTA). Demographics, tourniquet time and intra-operative fluoroscopy times were obtained from the hospital records. Results: There were 106 TAA in the SI group and 62 TAA in the PSI group. The was no significant difference in total MOXFQ, AOS or EQ5D. There was however a significant difference (p=.032) in favour of PSI in the walking/standing domain of the MOXFQ at 12 months. There was a significantly reduced tourniquet time (PSI mean: 95.39 mins, SI mean: 116.87 mins, p<.001) and radiation exposure (PSI mean: 31 seconds, SI mean: 53 seconds, p<.001). Angular correction was more accurate in the PSI group (PSI mean: 1.29°, SI mean: 2.26°, p=.005). Conclusion: This study supports the use of patient specific instrumentation to decrease operative time, reduce intraoperative fluoroscopy and improve accuracy of implantation in TAA. The walking/standing domain of the MOXFQ has been shown to be the most sensitive to change and in this study demonstrated a further potential benefit.
first_indexed 2024-04-12T06:47:17Z
format Article
id doaj.art-b9accd6714d14dea94f1a45888edee37
institution Directory Open Access Journal
issn 2473-0114
language English
last_indexed 2024-04-12T06:47:17Z
publishDate 2022-11-01
publisher SAGE Publishing
record_format Article
series Foot & Ankle Orthopaedics
spelling doaj.art-b9accd6714d14dea94f1a45888edee372022-12-22T03:43:29ZengSAGE PublishingFoot & Ankle Orthopaedics2473-01142022-11-01710.1177/2473011421S01012Patient Specific Instrumentation and Total Ankle ArthroplastyJames K. YauAn MurtyRajesh KakwaniDavid N. Townshend MBBS, FRCS(Tr&Orth)Category: Ankle Arthritis; Ankle Introduction/Purpose: Total Ankle Arthroplasty (TAA) can now be performed using Patient Specific Instrumentation (PSI). Advantages include the ability to pre-operatively plan bone resections and implant position and reduce the number of intra- operative surgical steps. The aim of this study was to compare PSI with Standard Instrumentation (SI) in a non-randomised retrospective cohort study with respect to patient reported outcomes, tourniquet time, fluoroscopy time and post-operative alignment. Methods: 159 patients (111 male, 48 female) undergoing a total of 168 INFINITY TAA using PSI (Prophecy, Wright Medical Technology) or SI between 2014 and 2020 were included with a minimum follow up of 12 months. Patient reported outcome measures (PROMS) were obtained pre-operatively and at one year and included the Manchester-Oxford Foot Questionnaire (MOXFQ), Ankle Osteoarthritis Scale (AOS) and EQ-5D Index. Coronal plane deformity correction was assessed using the midline tibiotalar angle (MTTA). Demographics, tourniquet time and intra-operative fluoroscopy times were obtained from the hospital records. Results: There were 106 TAA in the SI group and 62 TAA in the PSI group. The was no significant difference in total MOXFQ, AOS or EQ5D. There was however a significant difference (p=.032) in favour of PSI in the walking/standing domain of the MOXFQ at 12 months. There was a significantly reduced tourniquet time (PSI mean: 95.39 mins, SI mean: 116.87 mins, p<.001) and radiation exposure (PSI mean: 31 seconds, SI mean: 53 seconds, p<.001). Angular correction was more accurate in the PSI group (PSI mean: 1.29°, SI mean: 2.26°, p=.005). Conclusion: This study supports the use of patient specific instrumentation to decrease operative time, reduce intraoperative fluoroscopy and improve accuracy of implantation in TAA. The walking/standing domain of the MOXFQ has been shown to be the most sensitive to change and in this study demonstrated a further potential benefit.https://doi.org/10.1177/2473011421S01012
spellingShingle James K. Yau
An Murty
Rajesh Kakwani
David N. Townshend MBBS, FRCS(Tr&Orth)
Patient Specific Instrumentation and Total Ankle Arthroplasty
Foot & Ankle Orthopaedics
title Patient Specific Instrumentation and Total Ankle Arthroplasty
title_full Patient Specific Instrumentation and Total Ankle Arthroplasty
title_fullStr Patient Specific Instrumentation and Total Ankle Arthroplasty
title_full_unstemmed Patient Specific Instrumentation and Total Ankle Arthroplasty
title_short Patient Specific Instrumentation and Total Ankle Arthroplasty
title_sort patient specific instrumentation and total ankle arthroplasty
url https://doi.org/10.1177/2473011421S01012
work_keys_str_mv AT jameskyau patientspecificinstrumentationandtotalanklearthroplasty
AT anmurty patientspecificinstrumentationandtotalanklearthroplasty
AT rajeshkakwani patientspecificinstrumentationandtotalanklearthroplasty
AT davidntownshendmbbsfrcstrorth patientspecificinstrumentationandtotalanklearthroplasty