Compliance with the north American Society of Pacing and Electrophysiology guidelines on amiodarone monitoring in Riyadh, Saudi Arabia: a retrospective charts review study

Background Amiodarone is known for its efficacy as an antiarrhythmic agent; however, its extensive side-effect profile requires careful selection of patients and frequent monitoring. The purpose of this study was to evaluate the performance of the baseline tests before initiating amiodarone therapy...

Full description

Bibliographic Details
Main Authors: Bander Ahmed Albassam, Nouf Mohammed Almutairi, Sarah Fahad Aldosari, Hind Saleh Almodaimegh
Format: Article
Language:English
Published: Taylor & Francis Group 2020-12-01
Series:Journal of Pharmaceutical Policy and Practice
Subjects:
Online Access:http://dx.doi.org/10.1186/s40545-020-00235-1
_version_ 1827593270155280384
author Bander Ahmed Albassam
Nouf Mohammed Almutairi
Sarah Fahad Aldosari
Hind Saleh Almodaimegh
author_facet Bander Ahmed Albassam
Nouf Mohammed Almutairi
Sarah Fahad Aldosari
Hind Saleh Almodaimegh
author_sort Bander Ahmed Albassam
collection DOAJ
description Background Amiodarone is known for its efficacy as an antiarrhythmic agent; however, its extensive side-effect profile requires careful selection of patients and frequent monitoring. The purpose of this study was to evaluate the performance of the baseline tests before initiating amiodarone therapy and the on-going monitoring based on the North American Society of Pacing and Electrophysiology guidelines recommendations. Methods A retrospective descriptive charts review study included all patients who are 18 years of age and older and were started on oral amiodarone with a primary diagnosis of any type of cardiac arrhythmia from January 2016 to December 2018 in King Abdualziz Medical City, Riyadh, Saudi Arabia. The medical charts were reviewed and evaluated based on the performance of the recommended baseline and follow-up of chest X-ray (CXR), liver function test (LFT), thyroid function test (TFT) and electrocardiogram (ECG). The continuous variables were analyzed and presented as mean ± SD and the categorical variables were presented as percentages. Results Over the study period, 143 eligible participants on amiodarone therapy were included, with an average of 165 ± 207 days on amiodarone. Of patients, 36.4% had the entire recommended baseline assessments before initiating amiodarone. Our results indicated optimal compliance rates to the baseline tests of CXR (79.7%), LFT (79.7%) and ECG (86.7%). However, there was a lower compliance rate to TFT recommendations (40.6%). The compliance rate to the guideline recommendations related to the follow-up tests was minimal. On-going monitoring performance rates were 47.6% of CXR, 49% of LFT, 54.5% of ECG and 22.4% of TFT. Conclusion The compliance with the guideline recommendations related to amiodarone baseline assessments was optimal for all the baseline tests, except for TFT. However, the proportion of patients who received all the recommended baseline assessments was minimal. In addition, the performance of on-going monitoring was suboptimal for all the follow-up tests. Improvements could be made by establishing a local protocol for amiodarone monitoring and pharmacists participating in amiodarone therapy assessments.
first_indexed 2024-03-09T02:07:54Z
format Article
id doaj.art-b9b1d056290c4f5da3cf69621e25a6c3
institution Directory Open Access Journal
issn 2052-3211
language English
last_indexed 2024-03-09T02:07:54Z
publishDate 2020-12-01
publisher Taylor & Francis Group
record_format Article
series Journal of Pharmaceutical Policy and Practice
spelling doaj.art-b9b1d056290c4f5da3cf69621e25a6c32023-12-07T15:28:02ZengTaylor & Francis GroupJournal of Pharmaceutical Policy and Practice2052-32112020-12-0113110.1186/s40545-020-00235-112315161Compliance with the north American Society of Pacing and Electrophysiology guidelines on amiodarone monitoring in Riyadh, Saudi Arabia: a retrospective charts review studyBander Ahmed Albassam0Nouf Mohammed Almutairi1Sarah Fahad Aldosari2Hind Saleh Almodaimegh3College of Pharmacy,College of Pharmacy,College of Pharmacy,College of Pharmacy,Background Amiodarone is known for its efficacy as an antiarrhythmic agent; however, its extensive side-effect profile requires careful selection of patients and frequent monitoring. The purpose of this study was to evaluate the performance of the baseline tests before initiating amiodarone therapy and the on-going monitoring based on the North American Society of Pacing and Electrophysiology guidelines recommendations. Methods A retrospective descriptive charts review study included all patients who are 18 years of age and older and were started on oral amiodarone with a primary diagnosis of any type of cardiac arrhythmia from January 2016 to December 2018 in King Abdualziz Medical City, Riyadh, Saudi Arabia. The medical charts were reviewed and evaluated based on the performance of the recommended baseline and follow-up of chest X-ray (CXR), liver function test (LFT), thyroid function test (TFT) and electrocardiogram (ECG). The continuous variables were analyzed and presented as mean ± SD and the categorical variables were presented as percentages. Results Over the study period, 143 eligible participants on amiodarone therapy were included, with an average of 165 ± 207 days on amiodarone. Of patients, 36.4% had the entire recommended baseline assessments before initiating amiodarone. Our results indicated optimal compliance rates to the baseline tests of CXR (79.7%), LFT (79.7%) and ECG (86.7%). However, there was a lower compliance rate to TFT recommendations (40.6%). The compliance rate to the guideline recommendations related to the follow-up tests was minimal. On-going monitoring performance rates were 47.6% of CXR, 49% of LFT, 54.5% of ECG and 22.4% of TFT. Conclusion The compliance with the guideline recommendations related to amiodarone baseline assessments was optimal for all the baseline tests, except for TFT. However, the proportion of patients who received all the recommended baseline assessments was minimal. In addition, the performance of on-going monitoring was suboptimal for all the follow-up tests. Improvements could be made by establishing a local protocol for amiodarone monitoring and pharmacists participating in amiodarone therapy assessments.http://dx.doi.org/10.1186/s40545-020-00235-1amiodaronemonitoringbaselinefollow-upcomplianceadherenceguidelines
spellingShingle Bander Ahmed Albassam
Nouf Mohammed Almutairi
Sarah Fahad Aldosari
Hind Saleh Almodaimegh
Compliance with the north American Society of Pacing and Electrophysiology guidelines on amiodarone monitoring in Riyadh, Saudi Arabia: a retrospective charts review study
Journal of Pharmaceutical Policy and Practice
amiodarone
monitoring
baseline
follow-up
compliance
adherence
guidelines
title Compliance with the north American Society of Pacing and Electrophysiology guidelines on amiodarone monitoring in Riyadh, Saudi Arabia: a retrospective charts review study
title_full Compliance with the north American Society of Pacing and Electrophysiology guidelines on amiodarone monitoring in Riyadh, Saudi Arabia: a retrospective charts review study
title_fullStr Compliance with the north American Society of Pacing and Electrophysiology guidelines on amiodarone monitoring in Riyadh, Saudi Arabia: a retrospective charts review study
title_full_unstemmed Compliance with the north American Society of Pacing and Electrophysiology guidelines on amiodarone monitoring in Riyadh, Saudi Arabia: a retrospective charts review study
title_short Compliance with the north American Society of Pacing and Electrophysiology guidelines on amiodarone monitoring in Riyadh, Saudi Arabia: a retrospective charts review study
title_sort compliance with the north american society of pacing and electrophysiology guidelines on amiodarone monitoring in riyadh saudi arabia a retrospective charts review study
topic amiodarone
monitoring
baseline
follow-up
compliance
adherence
guidelines
url http://dx.doi.org/10.1186/s40545-020-00235-1
work_keys_str_mv AT banderahmedalbassam compliancewiththenorthamericansocietyofpacingandelectrophysiologyguidelinesonamiodaronemonitoringinriyadhsaudiarabiaaretrospectivechartsreviewstudy
AT noufmohammedalmutairi compliancewiththenorthamericansocietyofpacingandelectrophysiologyguidelinesonamiodaronemonitoringinriyadhsaudiarabiaaretrospectivechartsreviewstudy
AT sarahfahadaldosari compliancewiththenorthamericansocietyofpacingandelectrophysiologyguidelinesonamiodaronemonitoringinriyadhsaudiarabiaaretrospectivechartsreviewstudy
AT hindsalehalmodaimegh compliancewiththenorthamericansocietyofpacingandelectrophysiologyguidelinesonamiodaronemonitoringinriyadhsaudiarabiaaretrospectivechartsreviewstudy