Determination of Capacities of Two-Circuit Open-Air Electric Power Lines with Voltage of 35 kV

Calculations of phase capacity of two-circuit open-air electric power lines with voltage of 35 kV relative to the ground have been carried out. The paper gives values of capacities of open-air electric power lines with voltage of 35 kV which are located on two-circuit supports depending on the opera...

Full description

Bibliographic Details
Main Authors: M. A. Korotkevich, A. J. Ohremenko
Format: Article
Language:Russian
Published: Belarusian National Technical University 2004-10-01
Series:Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
Online Access:https://energy.bntu.by/jour/article/view/1165
_version_ 1797879985598365696
author M. A. Korotkevich
A. J. Ohremenko
author_facet M. A. Korotkevich
A. J. Ohremenko
author_sort M. A. Korotkevich
collection DOAJ
description Calculations of phase capacity of two-circuit open-air electric power lines with voltage of 35 kV relative to the ground have been carried out. The paper gives values of capacities of open-air electric power lines with voltage of 35 kV which are located on two-circuit supports depending on the operational mode of the second circuit. The values of capacity of a two- circuit electric power line have been determined provided that circuits of various rated voltage are located on a line. Changes in capacity of an electric power line with voltage of 35 kV have been calculated in comparison with the capacity of an one-circuit line depending on a distance between axes and the operational mode of the second line, if the lines are parallel.
first_indexed 2024-04-10T02:57:14Z
format Article
id doaj.art-ba839eae11224466a8fdcf825406458f
institution Directory Open Access Journal
issn 1029-7448
2414-0341
language Russian
last_indexed 2024-04-10T02:57:14Z
publishDate 2004-10-01
publisher Belarusian National Technical University
record_format Article
series Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
spelling doaj.art-ba839eae11224466a8fdcf825406458f2023-03-13T07:41:42ZrusBelarusian National Technical UniversityIzvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika1029-74482414-03412004-10-0105354110.21122/1029-7448-2004-0-5-35-411124Determination of Capacities of Two-Circuit Open-Air Electric Power Lines with Voltage of 35 kVM. A. Korotkevich0A. J. Ohremenko1Белорусский национальный технический университетБелорусский национальный технический университетCalculations of phase capacity of two-circuit open-air electric power lines with voltage of 35 kV relative to the ground have been carried out. The paper gives values of capacities of open-air electric power lines with voltage of 35 kV which are located on two-circuit supports depending on the operational mode of the second circuit. The values of capacity of a two- circuit electric power line have been determined provided that circuits of various rated voltage are located on a line. Changes in capacity of an electric power line with voltage of 35 kV have been calculated in comparison with the capacity of an one-circuit line depending on a distance between axes and the operational mode of the second line, if the lines are parallel.https://energy.bntu.by/jour/article/view/1165
spellingShingle M. A. Korotkevich
A. J. Ohremenko
Determination of Capacities of Two-Circuit Open-Air Electric Power Lines with Voltage of 35 kV
Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika
title Determination of Capacities of Two-Circuit Open-Air Electric Power Lines with Voltage of 35 kV
title_full Determination of Capacities of Two-Circuit Open-Air Electric Power Lines with Voltage of 35 kV
title_fullStr Determination of Capacities of Two-Circuit Open-Air Electric Power Lines with Voltage of 35 kV
title_full_unstemmed Determination of Capacities of Two-Circuit Open-Air Electric Power Lines with Voltage of 35 kV
title_short Determination of Capacities of Two-Circuit Open-Air Electric Power Lines with Voltage of 35 kV
title_sort determination of capacities of two circuit open air electric power lines with voltage of 35 kv
url https://energy.bntu.by/jour/article/view/1165
work_keys_str_mv AT makorotkevich determinationofcapacitiesoftwocircuitopenairelectricpowerlineswithvoltageof35kv
AT ajohremenko determinationofcapacitiesoftwocircuitopenairelectricpowerlineswithvoltageof35kv