Method for Assessment of Operation of Analog Filters Installed in the Measuring Lines for Electrical Quantities of a Mining Machine’s Converter Power Supply System

A method for assessing the operation of analog filters installed in the measuring paths of current and voltage converters in the power supply system of a mining machine motor, using the example of the driving unit of a roadheader’s cutterhead, is presented. The suggested method is based on the ident...

Full description

Bibliographic Details
Main Authors: Jarosław Joostberens, Arkadiusz Pawlikowski, Dariusz Prostański, Krzysztof Nieśpiałowski
Format: Article
Language:English
Published: MDPI AG 2021-04-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/14/9/2384
_version_ 1797536672553893888
author Jarosław Joostberens
Arkadiusz Pawlikowski
Dariusz Prostański
Krzysztof Nieśpiałowski
author_facet Jarosław Joostberens
Arkadiusz Pawlikowski
Dariusz Prostański
Krzysztof Nieśpiałowski
author_sort Jarosław Joostberens
collection DOAJ
description A method for assessing the operation of analog filters installed in the measuring paths of current and voltage converters in the power supply system of a mining machine motor, using the example of the driving unit of a roadheader’s cutterhead, is presented. The suggested method is based on the identification of the fundamental harmonic of signals from the current and voltage sensors observed at the input and output of the tested filters, respectively. The identified parameters of the fundamental harmonic of signals before and after the filter allow the determination of points of the filter frequency’s characteristics and their comparison with the reference values. In the suggested method of assessing the operation of analog filters, the new approach consists of checking the frequency characteristics on the basis of identification of the basic harmonics of the signal at the input and output of the tested filter (installed in the measuring line of the electrical quantity) using data acquired during the frequency start-up of the mining machine driving motor under normal operational conditions. Results are presented of the filter performance assessment, using the suggested method, after three years of its operation in the measuring system. For this purpose, empirical data recorded during the operation of a roadheader on a test stand are used. The results are compared with the theoretical frequency characteristics of the tested filters.
first_indexed 2024-03-10T12:04:05Z
format Article
id doaj.art-ba8e1a67f02a4857ac08f4cbe9dfbd75
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-03-10T12:04:05Z
publishDate 2021-04-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-ba8e1a67f02a4857ac08f4cbe9dfbd752023-11-21T16:43:41ZengMDPI AGEnergies1996-10732021-04-01149238410.3390/en14092384Method for Assessment of Operation of Analog Filters Installed in the Measuring Lines for Electrical Quantities of a Mining Machine’s Converter Power Supply SystemJarosław Joostberens0Arkadiusz Pawlikowski1Dariusz Prostański2Krzysztof Nieśpiałowski3Department of Electrical Engineering and Automation in Industry, Faculty of Mining, Safety Engineering and Industrial Automation, Silesian University of Technology, Akademicka 2 St., 44-100 Gliwice, PolandDepartment of Mechanization and Robotization of Mining, Faculty of Mining, Safety Engineering and Industrial Automation, Silesian University of Technology, Akademicka 2 St., 44-100 Gliwice, PolandKOMAG Institute of Mining Technology, Pszczynska 37 St., 44-101 Gliwice, PolandKOMAG Institute of Mining Technology, Pszczynska 37 St., 44-101 Gliwice, PolandA method for assessing the operation of analog filters installed in the measuring paths of current and voltage converters in the power supply system of a mining machine motor, using the example of the driving unit of a roadheader’s cutterhead, is presented. The suggested method is based on the identification of the fundamental harmonic of signals from the current and voltage sensors observed at the input and output of the tested filters, respectively. The identified parameters of the fundamental harmonic of signals before and after the filter allow the determination of points of the filter frequency’s characteristics and their comparison with the reference values. In the suggested method of assessing the operation of analog filters, the new approach consists of checking the frequency characteristics on the basis of identification of the basic harmonics of the signal at the input and output of the tested filter (installed in the measuring line of the electrical quantity) using data acquired during the frequency start-up of the mining machine driving motor under normal operational conditions. Results are presented of the filter performance assessment, using the suggested method, after three years of its operation in the measuring system. For this purpose, empirical data recorded during the operation of a roadheader on a test stand are used. The results are compared with the theoretical frequency characteristics of the tested filters.https://www.mdpi.com/1996-1073/14/9/2384analog filterfrequency characteristicsinduction motorinverterroadheader
spellingShingle Jarosław Joostberens
Arkadiusz Pawlikowski
Dariusz Prostański
Krzysztof Nieśpiałowski
Method for Assessment of Operation of Analog Filters Installed in the Measuring Lines for Electrical Quantities of a Mining Machine’s Converter Power Supply System
Energies
analog filter
frequency characteristics
induction motor
inverter
roadheader
title Method for Assessment of Operation of Analog Filters Installed in the Measuring Lines for Electrical Quantities of a Mining Machine’s Converter Power Supply System
title_full Method for Assessment of Operation of Analog Filters Installed in the Measuring Lines for Electrical Quantities of a Mining Machine’s Converter Power Supply System
title_fullStr Method for Assessment of Operation of Analog Filters Installed in the Measuring Lines for Electrical Quantities of a Mining Machine’s Converter Power Supply System
title_full_unstemmed Method for Assessment of Operation of Analog Filters Installed in the Measuring Lines for Electrical Quantities of a Mining Machine’s Converter Power Supply System
title_short Method for Assessment of Operation of Analog Filters Installed in the Measuring Lines for Electrical Quantities of a Mining Machine’s Converter Power Supply System
title_sort method for assessment of operation of analog filters installed in the measuring lines for electrical quantities of a mining machine s converter power supply system
topic analog filter
frequency characteristics
induction motor
inverter
roadheader
url https://www.mdpi.com/1996-1073/14/9/2384
work_keys_str_mv AT jarosławjoostberens methodforassessmentofoperationofanalogfiltersinstalledinthemeasuringlinesforelectricalquantitiesofaminingmachinesconverterpowersupplysystem
AT arkadiuszpawlikowski methodforassessmentofoperationofanalogfiltersinstalledinthemeasuringlinesforelectricalquantitiesofaminingmachinesconverterpowersupplysystem
AT dariuszprostanski methodforassessmentofoperationofanalogfiltersinstalledinthemeasuringlinesforelectricalquantitiesofaminingmachinesconverterpowersupplysystem
AT krzysztofniespiałowski methodforassessmentofoperationofanalogfiltersinstalledinthemeasuringlinesforelectricalquantitiesofaminingmachinesconverterpowersupplysystem