Study of Corrosion Resistance of Co-Cr-Mo Surgical Implants Alloy in Artificial Saliva
Co-Cr-Mo alloy has been used for biomedical implant for a number of years. In this study, ASTM F-75 Cobalt-base substrate specimen was immersed in artificial saliva at 37 + 1 ºC to study the corrosion resistance properties. Surface of specimen before and after the immersion was analyzed by optical m...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Unviversity of Technology- Iraq
2014-10-01
|
Series: | Engineering and Technology Journal |
Subjects: | |
Online Access: | https://etj.uotechnology.edu.iq/article_99987_7a83f7ead04ec59c8445591e16e506c8.pdf |
_version_ | 1797325672739241984 |
---|---|
author | Muna Khethier Abbass Sami Abualnoun Ajeel Haitham M. Wadullah |
author_facet | Muna Khethier Abbass Sami Abualnoun Ajeel Haitham M. Wadullah |
author_sort | Muna Khethier Abbass |
collection | DOAJ |
description | Co-Cr-Mo alloy has been used for biomedical implant for a number of years. In this study, ASTM F-75 Cobalt-base substrate specimen was immersed in artificial saliva at 37 + 1 ºC to study the corrosion resistance properties. Surface of specimen before and after the immersion was analyzed by optical microscope and Scanning Electron Microscopy (SEM). X-Ray Diffraction (XRD) was used to study the phase structure present. The metallic ions in the artificial saliva were analyzed after the corrosion test by Absorption Spectrophotometer (AAS). Electrochemical Measurements by polarization experiments were performed to study the corrosion resistance, the main results obtained were expressed in terms of the corrosion potentials (Ecorr) and corrosion current density (icorr) in addition to measure the Tafel slops by Tafel extrapolation method, and also cyclic polarization are used in artificial saliva solution. The results of galvanic corrosion show that the Co-Cr-Mo alloy had localized corrosion in artificial saliva at 37+1ºC. |
first_indexed | 2024-03-08T06:12:46Z |
format | Article |
id | doaj.art-baa15f031ee642898076c9a667529170 |
institution | Directory Open Access Journal |
issn | 1681-6900 2412-0758 |
language | English |
last_indexed | 2024-03-08T06:12:46Z |
publishDate | 2014-10-01 |
publisher | Unviversity of Technology- Iraq |
record_format | Article |
series | Engineering and Technology Journal |
spelling | doaj.art-baa15f031ee642898076c9a6675291702024-02-04T17:31:32ZengUnviversity of Technology- IraqEngineering and Technology Journal1681-69002412-07582014-10-0132102331233910.30684/etj.32.10A.199987Study of Corrosion Resistance of Co-Cr-Mo Surgical Implants Alloy in Artificial SalivaMuna Khethier AbbassSami Abualnoun AjeelHaitham M. WadullahCo-Cr-Mo alloy has been used for biomedical implant for a number of years. In this study, ASTM F-75 Cobalt-base substrate specimen was immersed in artificial saliva at 37 + 1 ºC to study the corrosion resistance properties. Surface of specimen before and after the immersion was analyzed by optical microscope and Scanning Electron Microscopy (SEM). X-Ray Diffraction (XRD) was used to study the phase structure present. The metallic ions in the artificial saliva were analyzed after the corrosion test by Absorption Spectrophotometer (AAS). Electrochemical Measurements by polarization experiments were performed to study the corrosion resistance, the main results obtained were expressed in terms of the corrosion potentials (Ecorr) and corrosion current density (icorr) in addition to measure the Tafel slops by Tafel extrapolation method, and also cyclic polarization are used in artificial saliva solution. The results of galvanic corrosion show that the Co-Cr-Mo alloy had localized corrosion in artificial saliva at 37+1ºC.https://etj.uotechnology.edu.iq/article_99987_7a83f7ead04ec59c8445591e16e506c8.pdfcorrosion of como alloysurgical implantsartificial saliva |
spellingShingle | Muna Khethier Abbass Sami Abualnoun Ajeel Haitham M. Wadullah Study of Corrosion Resistance of Co-Cr-Mo Surgical Implants Alloy in Artificial Saliva Engineering and Technology Journal corrosion of co mo alloy surgical implants artificial saliva |
title | Study of Corrosion Resistance of Co-Cr-Mo Surgical Implants Alloy in Artificial Saliva |
title_full | Study of Corrosion Resistance of Co-Cr-Mo Surgical Implants Alloy in Artificial Saliva |
title_fullStr | Study of Corrosion Resistance of Co-Cr-Mo Surgical Implants Alloy in Artificial Saliva |
title_full_unstemmed | Study of Corrosion Resistance of Co-Cr-Mo Surgical Implants Alloy in Artificial Saliva |
title_short | Study of Corrosion Resistance of Co-Cr-Mo Surgical Implants Alloy in Artificial Saliva |
title_sort | study of corrosion resistance of co cr mo surgical implants alloy in artificial saliva |
topic | corrosion of co mo alloy surgical implants artificial saliva |
url | https://etj.uotechnology.edu.iq/article_99987_7a83f7ead04ec59c8445591e16e506c8.pdf |
work_keys_str_mv | AT munakhethierabbass studyofcorrosionresistanceofcocrmosurgicalimplantsalloyinartificialsaliva AT samiabualnounajeel studyofcorrosionresistanceofcocrmosurgicalimplantsalloyinartificialsaliva AT haithammwadullah studyofcorrosionresistanceofcocrmosurgicalimplantsalloyinartificialsaliva |