Ultrasound-guided radial artery cannulation: A report of a simple and low-cost model for training
Introduction: Practicing models for invasive procedure have proven useful in achieving better rates of success for physicians in training. Often, these models are not easy to get because of its expensive price. Radial artery cannulation is a common practice and its performance with ultrasonographic...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2023-01-01
|
Series: | Educación Médica |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S1575181322000808 |
_version_ | 1811159985905729536 |
---|---|
author | Alejandro Sierra-González de Cossio Carlos Dattoli-García Enma Toledo-Alemán Fabio Solís-Jimenez Montserrat Villalobos-Pedroza Jesús Antonio Viana-Rojas Jose Omar Arenas-Díaz Daniel Manzur-Sandoval |
author_facet | Alejandro Sierra-González de Cossio Carlos Dattoli-García Enma Toledo-Alemán Fabio Solís-Jimenez Montserrat Villalobos-Pedroza Jesús Antonio Viana-Rojas Jose Omar Arenas-Díaz Daniel Manzur-Sandoval |
author_sort | Alejandro Sierra-González de Cossio |
collection | DOAJ |
description | Introduction: Practicing models for invasive procedure have proven useful in achieving better rates of success for physicians in training. Often, these models are not easy to get because of its expensive price. Radial artery cannulation is a common practice and its performance with ultrasonographic guidance has proven to be more efficient than traditional ways. We developed a low-cost practicing model that may aid physicians in training to master the ultrasound-guided radial artery cannulation technique and achieve better rates of success when performing this procedure. Methods: Using ordinary materials such as a piece of pork ham and rubber torniquets, we were able to build a 3-vessel artery model with pulsatile flow. Results: Ultrasonographic imaging revealed a vessel-like material embedded inside the piece of ham. This material resembles an artery which can be punctured with an in-plane or out-of-plane technique and cannulated afterwards, either with a Seldinger or a modified Seldinger technique. Once cannulated, pulsatile flow can be obtained through the catheter used. Conclusion: Our model building time was 30 minutes, and its price doesn’t exceed more than $7.50 USD. This model can be used by physicians in training to practice the cannulation of a radial artery using ultrasonographic guidance. Resumen: Introducción: Los modelos de práctica para procedimientos invasivos han probado ser útiles en mejorar las tasas de éxito de los médicos en entrenamiento que llevan a cabo tales procedimientos.Frecuentemente, estos modelos son de difícil acceso debido a su elevado precio. La canulación de la arteria radial es una práctica común y la técnica con guía ultrasonográfica ha demostrado ser más eficiente que la técnica convencional. Desarrollamos un modelo de bajo costo que puede ayudar a los médicos en entrenamiento a perfeccionar ésta técnica y conseguir mejores tasas de éxito al realizar este procedimiento. Métodos: Utilizando materiales ordinaries como una pieza de jamón de cerdo y torniquetes huecos de hule, pudimos construir un modelo de simulación de 3 vasos arteriales con flujo pulsátil. Resultados: La ultrasonografía del modelo reveló que el material dentro del jamón tiene un gran parecido a una arteria radial. Este material tiene flujo pulsátil y mediante guía ultrasonográfica con técnica “En-plano” o “Fuera-de-plano” puede ser puncionado y canulado posteriormente ya sea con técnica Seldinger o Seldinger modificado y también permite observar el retorno de un flujo pulsátil a través de la cánula utilizada. Conclusión: El tiempo de construcción de nuestro modelo no excede los 30 minutos y el precio para hacerlo no asciende a más de $7.50 USD. Este modelo puede ser utilizado por personal de la salud en entrenamiento para practicar y perfeccionar la técnica de canulación radial con guía ultrasonográfica. |
first_indexed | 2024-04-10T05:50:00Z |
format | Article |
id | doaj.art-bb0650679d354c219e88907b2246d4d4 |
institution | Directory Open Access Journal |
issn | 1575-1813 |
language | English |
last_indexed | 2024-04-10T05:50:00Z |
publishDate | 2023-01-01 |
publisher | Elsevier |
record_format | Article |
series | Educación Médica |
spelling | doaj.art-bb0650679d354c219e88907b2246d4d42023-03-05T04:23:38ZengElsevierEducación Médica1575-18132023-01-01241100788Ultrasound-guided radial artery cannulation: A report of a simple and low-cost model for trainingAlejandro Sierra-González de Cossio0Carlos Dattoli-García1Enma Toledo-Alemán2Fabio Solís-Jimenez3Montserrat Villalobos-Pedroza4Jesús Antonio Viana-Rojas5Jose Omar Arenas-Díaz6Daniel Manzur-Sandoval7Education Department, Instituto Nacional de Cardiología Ignacio Chávez, Mexico City, MexicoEducation Department, Instituto Nacional de Cardiología Ignacio Chávez, Mexico City, MexicoEducation Department, Instituto Nacional de Cardiología Ignacio Chávez, Mexico City, MexicoEducation Department, Instituto Nacional de Cardiología Ignacio Chávez, Mexico City, MexicoEducation Department, Instituto Nacional de Cardiología Ignacio Chávez, Mexico City, MexicoEducation Department, Instituto Nacional de Cardiología Ignacio Chávez, Mexico City, MexicoEducation Department, Instituto Nacional de Cardiología Ignacio Chávez, Mexico City, MexicoEducation Department, Instituto Nacional de Cardiología Ignacio Chávez, Mexico City, Mexico; Cardiovascular Critical Care Unit, Instituto Nacional de Cardiología Ignacio Chávez, Mexico City, Mexico; Corresponding author.Introduction: Practicing models for invasive procedure have proven useful in achieving better rates of success for physicians in training. Often, these models are not easy to get because of its expensive price. Radial artery cannulation is a common practice and its performance with ultrasonographic guidance has proven to be more efficient than traditional ways. We developed a low-cost practicing model that may aid physicians in training to master the ultrasound-guided radial artery cannulation technique and achieve better rates of success when performing this procedure. Methods: Using ordinary materials such as a piece of pork ham and rubber torniquets, we were able to build a 3-vessel artery model with pulsatile flow. Results: Ultrasonographic imaging revealed a vessel-like material embedded inside the piece of ham. This material resembles an artery which can be punctured with an in-plane or out-of-plane technique and cannulated afterwards, either with a Seldinger or a modified Seldinger technique. Once cannulated, pulsatile flow can be obtained through the catheter used. Conclusion: Our model building time was 30 minutes, and its price doesn’t exceed more than $7.50 USD. This model can be used by physicians in training to practice the cannulation of a radial artery using ultrasonographic guidance. Resumen: Introducción: Los modelos de práctica para procedimientos invasivos han probado ser útiles en mejorar las tasas de éxito de los médicos en entrenamiento que llevan a cabo tales procedimientos.Frecuentemente, estos modelos son de difícil acceso debido a su elevado precio. La canulación de la arteria radial es una práctica común y la técnica con guía ultrasonográfica ha demostrado ser más eficiente que la técnica convencional. Desarrollamos un modelo de bajo costo que puede ayudar a los médicos en entrenamiento a perfeccionar ésta técnica y conseguir mejores tasas de éxito al realizar este procedimiento. Métodos: Utilizando materiales ordinaries como una pieza de jamón de cerdo y torniquetes huecos de hule, pudimos construir un modelo de simulación de 3 vasos arteriales con flujo pulsátil. Resultados: La ultrasonografía del modelo reveló que el material dentro del jamón tiene un gran parecido a una arteria radial. Este material tiene flujo pulsátil y mediante guía ultrasonográfica con técnica “En-plano” o “Fuera-de-plano” puede ser puncionado y canulado posteriormente ya sea con técnica Seldinger o Seldinger modificado y también permite observar el retorno de un flujo pulsátil a través de la cánula utilizada. Conclusión: El tiempo de construcción de nuestro modelo no excede los 30 minutos y el precio para hacerlo no asciende a más de $7.50 USD. Este modelo puede ser utilizado por personal de la salud en entrenamiento para practicar y perfeccionar la técnica de canulación radial con guía ultrasonográfica.http://www.sciencedirect.com/science/article/pii/S1575181322000808Arteria radialEducación médicaCanulación guiada por ultrasonido |
spellingShingle | Alejandro Sierra-González de Cossio Carlos Dattoli-García Enma Toledo-Alemán Fabio Solís-Jimenez Montserrat Villalobos-Pedroza Jesús Antonio Viana-Rojas Jose Omar Arenas-Díaz Daniel Manzur-Sandoval Ultrasound-guided radial artery cannulation: A report of a simple and low-cost model for training Educación Médica Arteria radial Educación médica Canulación guiada por ultrasonido |
title | Ultrasound-guided radial artery cannulation: A report of a simple and low-cost model for training |
title_full | Ultrasound-guided radial artery cannulation: A report of a simple and low-cost model for training |
title_fullStr | Ultrasound-guided radial artery cannulation: A report of a simple and low-cost model for training |
title_full_unstemmed | Ultrasound-guided radial artery cannulation: A report of a simple and low-cost model for training |
title_short | Ultrasound-guided radial artery cannulation: A report of a simple and low-cost model for training |
title_sort | ultrasound guided radial artery cannulation a report of a simple and low cost model for training |
topic | Arteria radial Educación médica Canulación guiada por ultrasonido |
url | http://www.sciencedirect.com/science/article/pii/S1575181322000808 |
work_keys_str_mv | AT alejandrosierragonzalezdecossio ultrasoundguidedradialarterycannulationareportofasimpleandlowcostmodelfortraining AT carlosdattoligarcia ultrasoundguidedradialarterycannulationareportofasimpleandlowcostmodelfortraining AT enmatoledoaleman ultrasoundguidedradialarterycannulationareportofasimpleandlowcostmodelfortraining AT fabiosolisjimenez ultrasoundguidedradialarterycannulationareportofasimpleandlowcostmodelfortraining AT montserratvillalobospedroza ultrasoundguidedradialarterycannulationareportofasimpleandlowcostmodelfortraining AT jesusantoniovianarojas ultrasoundguidedradialarterycannulationareportofasimpleandlowcostmodelfortraining AT joseomararenasdiaz ultrasoundguidedradialarterycannulationareportofasimpleandlowcostmodelfortraining AT danielmanzursandoval ultrasoundguidedradialarterycannulationareportofasimpleandlowcostmodelfortraining |