Parametric optimization of autoclave curing for energy cost reduction of fiber cement panels

The results of experimental research on parametric optimization of autoclave curing for energy cost reduction of fiber cement panels are presented. Relation between the flexural strength of fiber cement panels and heating rate, the time of isothermal aging, the cooling rate of the autoclave has been...

Full description

Bibliographic Details
Main Authors: Mukhametrakhimov Rustem, Lukmanova Liliya
Format: Article
Language:English
Published: EDP Sciences 2018-01-01
Series:MATEC Web of Conferences
Online Access:https://doi.org/10.1051/matecconf/201817003029
_version_ 1818737326543601664
author Mukhametrakhimov Rustem
Lukmanova Liliya
author_facet Mukhametrakhimov Rustem
Lukmanova Liliya
author_sort Mukhametrakhimov Rustem
collection DOAJ
description The results of experimental research on parametric optimization of autoclave curing for energy cost reduction of fiber cement panels are presented. Relation between the flexural strength of fiber cement panels and heating rate, the time of isothermal aging, the cooling rate of the autoclave has been established by the three-factor design of the second order.
first_indexed 2024-12-18T00:51:16Z
format Article
id doaj.art-bb1ef32b87b947dda355ce789938ede4
institution Directory Open Access Journal
issn 2261-236X
language English
last_indexed 2024-12-18T00:51:16Z
publishDate 2018-01-01
publisher EDP Sciences
record_format Article
series MATEC Web of Conferences
spelling doaj.art-bb1ef32b87b947dda355ce789938ede42022-12-21T21:26:39ZengEDP SciencesMATEC Web of Conferences2261-236X2018-01-011700302910.1051/matecconf/201817003029matecconf_spbwosce2018_03029Parametric optimization of autoclave curing for energy cost reduction of fiber cement panelsMukhametrakhimov RustemLukmanova LiliyaThe results of experimental research on parametric optimization of autoclave curing for energy cost reduction of fiber cement panels are presented. Relation between the flexural strength of fiber cement panels and heating rate, the time of isothermal aging, the cooling rate of the autoclave has been established by the three-factor design of the second order.https://doi.org/10.1051/matecconf/201817003029
spellingShingle Mukhametrakhimov Rustem
Lukmanova Liliya
Parametric optimization of autoclave curing for energy cost reduction of fiber cement panels
MATEC Web of Conferences
title Parametric optimization of autoclave curing for energy cost reduction of fiber cement panels
title_full Parametric optimization of autoclave curing for energy cost reduction of fiber cement panels
title_fullStr Parametric optimization of autoclave curing for energy cost reduction of fiber cement panels
title_full_unstemmed Parametric optimization of autoclave curing for energy cost reduction of fiber cement panels
title_short Parametric optimization of autoclave curing for energy cost reduction of fiber cement panels
title_sort parametric optimization of autoclave curing for energy cost reduction of fiber cement panels
url https://doi.org/10.1051/matecconf/201817003029
work_keys_str_mv AT mukhametrakhimovrustem parametricoptimizationofautoclavecuringforenergycostreductionoffibercementpanels
AT lukmanovaliliya parametricoptimizationofautoclavecuringforenergycostreductionoffibercementpanels