Influence Factors and Elimination on Iron Content Using ICP-AES Method in Oilfield Produced Water
ICP-AES method can be used to determine multiple metallic elements simultaneously, and has the advantages of high sensitivity, good repeatability and high accuracy. In the paper, the detection limit of iron content was determined by stepwise dilution method. The influence of the cationic concentrati...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2022-01-01
|
Series: | E3S Web of Conferences |
Online Access: | https://www.e3s-conferences.org/articles/e3sconf/pdf/2022/19/e3sconf_esat2022_01090.pdf |
_version_ | 1811227653830606848 |
---|---|
author | Wang Xinqiang Guo Zilong Chen Xing Liu Zhuang Yang Nan Xie Juan |
author_facet | Wang Xinqiang Guo Zilong Chen Xing Liu Zhuang Yang Nan Xie Juan |
author_sort | Wang Xinqiang |
collection | DOAJ |
description | ICP-AES method can be used to determine multiple metallic elements simultaneously, and has the advantages of high sensitivity, good repeatability and high accuracy. In the paper, the detection limit of iron content was determined by stepwise dilution method. The influence of the cationic concentration on the determination of iron element was studied, and the matrix matching method was proposed to eliminate the influence. The results show that, the determination limit of Iron element is 0.01 mg·L-1. Because the other cationic content is several times or even tens of times as much as iron ions, it has a great influence on the determination results of Iron element. The effects of cationic concentration can be effectively eliminated by establishing a standard curve using matrix matching. After digestion pretreatment on the oil and gas field produce water, The standard adding recovery rate was between 95% and 105%, and the RSD is less than 4%. Compare this method with o-phenanthroline spectrophotometry, its relative error is within 5%. Therefore, ICP-AES method can fully meet the requirements of determination of iron content in oil field produce water, and greatly improves the efficiency and accuracy of the laboratory analysis of oil and as field wastewater. |
first_indexed | 2024-04-12T09:45:44Z |
format | Article |
id | doaj.art-bb231040200e46268df6986b2d1ded43 |
institution | Directory Open Access Journal |
issn | 2267-1242 |
language | English |
last_indexed | 2024-04-12T09:45:44Z |
publishDate | 2022-01-01 |
publisher | EDP Sciences |
record_format | Article |
series | E3S Web of Conferences |
spelling | doaj.art-bb231040200e46268df6986b2d1ded432022-12-22T03:37:57ZengEDP SciencesE3S Web of Conferences2267-12422022-01-013520109010.1051/e3sconf/202235201090e3sconf_esat2022_01090Influence Factors and Elimination on Iron Content Using ICP-AES Method in Oilfield Produced WaterWang Xinqiang0Guo Zilong1Chen Xing2Liu Zhuang3Yang Nan4Xie Juan5Shaanxi Province Key Laboratory of Environmental Pollution Control and Reservoir Protection Technology of Oilfields, College of Chemistry and Chemical Engineering, Xi’an Shiyou UniversityNo.4 Oil Production Plant, Changqing Oilfield CompanyNo.2 Gas Production Plant, Changqing Oilfield CompanyNo.2 Gas Production Plant, Changqing Oilfield CompanyXi’an Key Laboratory of Tight oil (Shale oil) Development, College of Petroleum Engineering, Xi’an Shiyou UniversityShaanxi Province Key Laboratory of Environmental Pollution Control and Reservoir Protection Technology of Oilfields, College of Chemistry and Chemical Engineering, Xi’an Shiyou UniversityICP-AES method can be used to determine multiple metallic elements simultaneously, and has the advantages of high sensitivity, good repeatability and high accuracy. In the paper, the detection limit of iron content was determined by stepwise dilution method. The influence of the cationic concentration on the determination of iron element was studied, and the matrix matching method was proposed to eliminate the influence. The results show that, the determination limit of Iron element is 0.01 mg·L-1. Because the other cationic content is several times or even tens of times as much as iron ions, it has a great influence on the determination results of Iron element. The effects of cationic concentration can be effectively eliminated by establishing a standard curve using matrix matching. After digestion pretreatment on the oil and gas field produce water, The standard adding recovery rate was between 95% and 105%, and the RSD is less than 4%. Compare this method with o-phenanthroline spectrophotometry, its relative error is within 5%. Therefore, ICP-AES method can fully meet the requirements of determination of iron content in oil field produce water, and greatly improves the efficiency and accuracy of the laboratory analysis of oil and as field wastewater.https://www.e3s-conferences.org/articles/e3sconf/pdf/2022/19/e3sconf_esat2022_01090.pdf |
spellingShingle | Wang Xinqiang Guo Zilong Chen Xing Liu Zhuang Yang Nan Xie Juan Influence Factors and Elimination on Iron Content Using ICP-AES Method in Oilfield Produced Water E3S Web of Conferences |
title | Influence Factors and Elimination on Iron Content Using ICP-AES Method in Oilfield Produced Water |
title_full | Influence Factors and Elimination on Iron Content Using ICP-AES Method in Oilfield Produced Water |
title_fullStr | Influence Factors and Elimination on Iron Content Using ICP-AES Method in Oilfield Produced Water |
title_full_unstemmed | Influence Factors and Elimination on Iron Content Using ICP-AES Method in Oilfield Produced Water |
title_short | Influence Factors and Elimination on Iron Content Using ICP-AES Method in Oilfield Produced Water |
title_sort | influence factors and elimination on iron content using icp aes method in oilfield produced water |
url | https://www.e3s-conferences.org/articles/e3sconf/pdf/2022/19/e3sconf_esat2022_01090.pdf |
work_keys_str_mv | AT wangxinqiang influencefactorsandeliminationonironcontentusingicpaesmethodinoilfieldproducedwater AT guozilong influencefactorsandeliminationonironcontentusingicpaesmethodinoilfieldproducedwater AT chenxing influencefactorsandeliminationonironcontentusingicpaesmethodinoilfieldproducedwater AT liuzhuang influencefactorsandeliminationonironcontentusingicpaesmethodinoilfieldproducedwater AT yangnan influencefactorsandeliminationonironcontentusingicpaesmethodinoilfieldproducedwater AT xiejuan influencefactorsandeliminationonironcontentusingicpaesmethodinoilfieldproducedwater |