Influence Factors and Elimination on Iron Content Using ICP-AES Method in Oilfield Produced Water

ICP-AES method can be used to determine multiple metallic elements simultaneously, and has the advantages of high sensitivity, good repeatability and high accuracy. In the paper, the detection limit of iron content was determined by stepwise dilution method. The influence of the cationic concentrati...

Full description

Bibliographic Details
Main Authors: Wang Xinqiang, Guo Zilong, Chen Xing, Liu Zhuang, Yang Nan, Xie Juan
Format: Article
Language:English
Published: EDP Sciences 2022-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2022/19/e3sconf_esat2022_01090.pdf
_version_ 1811227653830606848
author Wang Xinqiang
Guo Zilong
Chen Xing
Liu Zhuang
Yang Nan
Xie Juan
author_facet Wang Xinqiang
Guo Zilong
Chen Xing
Liu Zhuang
Yang Nan
Xie Juan
author_sort Wang Xinqiang
collection DOAJ
description ICP-AES method can be used to determine multiple metallic elements simultaneously, and has the advantages of high sensitivity, good repeatability and high accuracy. In the paper, the detection limit of iron content was determined by stepwise dilution method. The influence of the cationic concentration on the determination of iron element was studied, and the matrix matching method was proposed to eliminate the influence. The results show that, the determination limit of Iron element is 0.01 mg·L-1. Because the other cationic content is several times or even tens of times as much as iron ions, it has a great influence on the determination results of Iron element. The effects of cationic concentration can be effectively eliminated by establishing a standard curve using matrix matching. After digestion pretreatment on the oil and gas field produce water, The standard adding recovery rate was between 95% and 105%, and the RSD is less than 4%. Compare this method with o-phenanthroline spectrophotometry, its relative error is within 5%. Therefore, ICP-AES method can fully meet the requirements of determination of iron content in oil field produce water, and greatly improves the efficiency and accuracy of the laboratory analysis of oil and as field wastewater.
first_indexed 2024-04-12T09:45:44Z
format Article
id doaj.art-bb231040200e46268df6986b2d1ded43
institution Directory Open Access Journal
issn 2267-1242
language English
last_indexed 2024-04-12T09:45:44Z
publishDate 2022-01-01
publisher EDP Sciences
record_format Article
series E3S Web of Conferences
spelling doaj.art-bb231040200e46268df6986b2d1ded432022-12-22T03:37:57ZengEDP SciencesE3S Web of Conferences2267-12422022-01-013520109010.1051/e3sconf/202235201090e3sconf_esat2022_01090Influence Factors and Elimination on Iron Content Using ICP-AES Method in Oilfield Produced WaterWang Xinqiang0Guo Zilong1Chen Xing2Liu Zhuang3Yang Nan4Xie Juan5Shaanxi Province Key Laboratory of Environmental Pollution Control and Reservoir Protection Technology of Oilfields, College of Chemistry and Chemical Engineering, Xi’an Shiyou UniversityNo.4 Oil Production Plant, Changqing Oilfield CompanyNo.2 Gas Production Plant, Changqing Oilfield CompanyNo.2 Gas Production Plant, Changqing Oilfield CompanyXi’an Key Laboratory of Tight oil (Shale oil) Development, College of Petroleum Engineering, Xi’an Shiyou UniversityShaanxi Province Key Laboratory of Environmental Pollution Control and Reservoir Protection Technology of Oilfields, College of Chemistry and Chemical Engineering, Xi’an Shiyou UniversityICP-AES method can be used to determine multiple metallic elements simultaneously, and has the advantages of high sensitivity, good repeatability and high accuracy. In the paper, the detection limit of iron content was determined by stepwise dilution method. The influence of the cationic concentration on the determination of iron element was studied, and the matrix matching method was proposed to eliminate the influence. The results show that, the determination limit of Iron element is 0.01 mg·L-1. Because the other cationic content is several times or even tens of times as much as iron ions, it has a great influence on the determination results of Iron element. The effects of cationic concentration can be effectively eliminated by establishing a standard curve using matrix matching. After digestion pretreatment on the oil and gas field produce water, The standard adding recovery rate was between 95% and 105%, and the RSD is less than 4%. Compare this method with o-phenanthroline spectrophotometry, its relative error is within 5%. Therefore, ICP-AES method can fully meet the requirements of determination of iron content in oil field produce water, and greatly improves the efficiency and accuracy of the laboratory analysis of oil and as field wastewater.https://www.e3s-conferences.org/articles/e3sconf/pdf/2022/19/e3sconf_esat2022_01090.pdf
spellingShingle Wang Xinqiang
Guo Zilong
Chen Xing
Liu Zhuang
Yang Nan
Xie Juan
Influence Factors and Elimination on Iron Content Using ICP-AES Method in Oilfield Produced Water
E3S Web of Conferences
title Influence Factors and Elimination on Iron Content Using ICP-AES Method in Oilfield Produced Water
title_full Influence Factors and Elimination on Iron Content Using ICP-AES Method in Oilfield Produced Water
title_fullStr Influence Factors and Elimination on Iron Content Using ICP-AES Method in Oilfield Produced Water
title_full_unstemmed Influence Factors and Elimination on Iron Content Using ICP-AES Method in Oilfield Produced Water
title_short Influence Factors and Elimination on Iron Content Using ICP-AES Method in Oilfield Produced Water
title_sort influence factors and elimination on iron content using icp aes method in oilfield produced water
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2022/19/e3sconf_esat2022_01090.pdf
work_keys_str_mv AT wangxinqiang influencefactorsandeliminationonironcontentusingicpaesmethodinoilfieldproducedwater
AT guozilong influencefactorsandeliminationonironcontentusingicpaesmethodinoilfieldproducedwater
AT chenxing influencefactorsandeliminationonironcontentusingicpaesmethodinoilfieldproducedwater
AT liuzhuang influencefactorsandeliminationonironcontentusingicpaesmethodinoilfieldproducedwater
AT yangnan influencefactorsandeliminationonironcontentusingicpaesmethodinoilfieldproducedwater
AT xiejuan influencefactorsandeliminationonironcontentusingicpaesmethodinoilfieldproducedwater