Comparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplasty
Purpose: Post-Descemet stripping endothelial keratoplasty (DSEK) patients are prone for intraocular pressure (IOP) elevations and glaucoma. Corneal characteristics influence various IOP measuring devices in various ways. The aim of this study was to evaluate the agreement between four different IOP...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wolters Kluwer Medknow Publications
2017-01-01
|
Series: | Indian Journal of Ophthalmology |
Subjects: | |
Online Access: | http://www.ijo.in/article.asp?issn=0301-4738;year=2017;volume=65;issue=7;spage=579;epage=583;aulast=Ohana |
_version_ | 1819019932373876736 |
---|---|
author | Oded Ohana David Varssano Gabi Shemesh |
author_facet | Oded Ohana David Varssano Gabi Shemesh |
author_sort | Oded Ohana |
collection | DOAJ |
description | Purpose: Post-Descemet stripping endothelial keratoplasty (DSEK) patients are prone for intraocular pressure (IOP) elevations and glaucoma. Corneal characteristics influence various IOP measuring devices in various ways. The aim of this study was to evaluate the agreement between four different IOP measuring devices: Goldmann applanation tonometer (GAT), I-care pro, Tonopen XL, and Schiotz tonometr in patients who underwent DSEK. Methods: This was a prospective comparative study using a convenience cohort of post-DSEK patients with compact grafts. Post-DSEK patients had IOP measured using GAT, I-care Pro, Tonopen XL, and Schiotz tonometer. Measurements were compared and agreement assessed. Wilcoxon signed-rank test was used for comparison of means as variables did not show a normal distribution. Bland–Altman plots were used for assessing agreement. Results: Thirty eyes of 24 patients were included in the study. Mean time from DSEK surgery was 25.31 ± 13.05 months. Mean IOP with GAT, I-care pro, Tonopen XL, and Schiotz tonometer was 13.99 ± 3.76, 13.92 ± 3.36, 13.31 ± 3.89, and 12.83 ± 4.07, respectively. GAT, I-care pro, and Tonopen XL had similar mean IOP measurements (P = 0.135 and P = 0.551, respectively), while Schiotz tonometry measurements were higher (P = 0.046). Bland–Altman plots show good agreement between GAT, Tonopen XL, and I-care pro. GAT and Schiotz tonometry show less agreement, with large variations in the differences of measured IOP. Conclusions: IOP measurements in post-DSEK patients showed good agreement between GAT and either Tonopen XL or I-care pro. Schiotz tonometer has large variations in this patient group. IOP measurements and IOP difference between devices were not dependent on central corneal thickness. |
first_indexed | 2024-12-21T03:43:10Z |
format | Article |
id | doaj.art-bb680518977240b8a4dee986990cc932 |
institution | Directory Open Access Journal |
issn | 0301-4738 1998-3689 |
language | English |
last_indexed | 2024-12-21T03:43:10Z |
publishDate | 2017-01-01 |
publisher | Wolters Kluwer Medknow Publications |
record_format | Article |
series | Indian Journal of Ophthalmology |
spelling | doaj.art-bb680518977240b8a4dee986990cc9322022-12-21T19:17:09ZengWolters Kluwer Medknow PublicationsIndian Journal of Ophthalmology0301-47381998-36892017-01-0165757958310.4103/ijo.IJO_31_17Comparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplastyOded OhanaDavid VarssanoGabi ShemeshPurpose: Post-Descemet stripping endothelial keratoplasty (DSEK) patients are prone for intraocular pressure (IOP) elevations and glaucoma. Corneal characteristics influence various IOP measuring devices in various ways. The aim of this study was to evaluate the agreement between four different IOP measuring devices: Goldmann applanation tonometer (GAT), I-care pro, Tonopen XL, and Schiotz tonometr in patients who underwent DSEK. Methods: This was a prospective comparative study using a convenience cohort of post-DSEK patients with compact grafts. Post-DSEK patients had IOP measured using GAT, I-care Pro, Tonopen XL, and Schiotz tonometer. Measurements were compared and agreement assessed. Wilcoxon signed-rank test was used for comparison of means as variables did not show a normal distribution. Bland–Altman plots were used for assessing agreement. Results: Thirty eyes of 24 patients were included in the study. Mean time from DSEK surgery was 25.31 ± 13.05 months. Mean IOP with GAT, I-care pro, Tonopen XL, and Schiotz tonometer was 13.99 ± 3.76, 13.92 ± 3.36, 13.31 ± 3.89, and 12.83 ± 4.07, respectively. GAT, I-care pro, and Tonopen XL had similar mean IOP measurements (P = 0.135 and P = 0.551, respectively), while Schiotz tonometry measurements were higher (P = 0.046). Bland–Altman plots show good agreement between GAT, Tonopen XL, and I-care pro. GAT and Schiotz tonometry show less agreement, with large variations in the differences of measured IOP. Conclusions: IOP measurements in post-DSEK patients showed good agreement between GAT and either Tonopen XL or I-care pro. Schiotz tonometer has large variations in this patient group. IOP measurements and IOP difference between devices were not dependent on central corneal thickness.http://www.ijo.in/article.asp?issn=0301-4738;year=2017;volume=65;issue=7;spage=579;epage=583;aulast=OhanaDescemet stripping endothelial keratoplastyI-careintraocular pressurerebound tonometrySchiotzTonometryTonopen |
spellingShingle | Oded Ohana David Varssano Gabi Shemesh Comparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplasty Indian Journal of Ophthalmology Descemet stripping endothelial keratoplasty I-care intraocular pressure rebound tonometry Schiotz Tonometry Tonopen |
title | Comparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplasty |
title_full | Comparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplasty |
title_fullStr | Comparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplasty |
title_full_unstemmed | Comparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplasty |
title_short | Comparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplasty |
title_sort | comparison of intraocular pressure measurements using goldmann tonometer i care pro tonopen xl and schiotz tonometer in patients after descemet stripping endothelial keratoplasty |
topic | Descemet stripping endothelial keratoplasty I-care intraocular pressure rebound tonometry Schiotz Tonometry Tonopen |
url | http://www.ijo.in/article.asp?issn=0301-4738;year=2017;volume=65;issue=7;spage=579;epage=583;aulast=Ohana |
work_keys_str_mv | AT odedohana comparisonofintraocularpressuremeasurementsusinggoldmanntonometericareprotonopenxlandschiotztonometerinpatientsafterdescemetstrippingendothelialkeratoplasty AT davidvarssano comparisonofintraocularpressuremeasurementsusinggoldmanntonometericareprotonopenxlandschiotztonometerinpatientsafterdescemetstrippingendothelialkeratoplasty AT gabishemesh comparisonofintraocularpressuremeasurementsusinggoldmanntonometericareprotonopenxlandschiotztonometerinpatientsafterdescemetstrippingendothelialkeratoplasty |