Comparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplasty

Purpose: Post-Descemet stripping endothelial keratoplasty (DSEK) patients are prone for intraocular pressure (IOP) elevations and glaucoma. Corneal characteristics influence various IOP measuring devices in various ways. The aim of this study was to evaluate the agreement between four different IOP...

Full description

Bibliographic Details
Main Authors: Oded Ohana, David Varssano, Gabi Shemesh
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2017-01-01
Series:Indian Journal of Ophthalmology
Subjects:
Online Access:http://www.ijo.in/article.asp?issn=0301-4738;year=2017;volume=65;issue=7;spage=579;epage=583;aulast=Ohana
_version_ 1819019932373876736
author Oded Ohana
David Varssano
Gabi Shemesh
author_facet Oded Ohana
David Varssano
Gabi Shemesh
author_sort Oded Ohana
collection DOAJ
description Purpose: Post-Descemet stripping endothelial keratoplasty (DSEK) patients are prone for intraocular pressure (IOP) elevations and glaucoma. Corneal characteristics influence various IOP measuring devices in various ways. The aim of this study was to evaluate the agreement between four different IOP measuring devices: Goldmann applanation tonometer (GAT), I-care pro, Tonopen XL, and Schiotz tonometr in patients who underwent DSEK. Methods: This was a prospective comparative study using a convenience cohort of post-DSEK patients with compact grafts. Post-DSEK patients had IOP measured using GAT, I-care Pro, Tonopen XL, and Schiotz tonometer. Measurements were compared and agreement assessed. Wilcoxon signed-rank test was used for comparison of means as variables did not show a normal distribution. Bland–Altman plots were used for assessing agreement. Results: Thirty eyes of 24 patients were included in the study. Mean time from DSEK surgery was 25.31 ± 13.05 months. Mean IOP with GAT, I-care pro, Tonopen XL, and Schiotz tonometer was 13.99 ± 3.76, 13.92 ± 3.36, 13.31 ± 3.89, and 12.83 ± 4.07, respectively. GAT, I-care pro, and Tonopen XL had similar mean IOP measurements (P = 0.135 and P = 0.551, respectively), while Schiotz tonometry measurements were higher (P = 0.046). Bland–Altman plots show good agreement between GAT, Tonopen XL, and I-care pro. GAT and Schiotz tonometry show less agreement, with large variations in the differences of measured IOP. Conclusions: IOP measurements in post-DSEK patients showed good agreement between GAT and either Tonopen XL or I-care pro. Schiotz tonometer has large variations in this patient group. IOP measurements and IOP difference between devices were not dependent on central corneal thickness.
first_indexed 2024-12-21T03:43:10Z
format Article
id doaj.art-bb680518977240b8a4dee986990cc932
institution Directory Open Access Journal
issn 0301-4738
1998-3689
language English
last_indexed 2024-12-21T03:43:10Z
publishDate 2017-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Indian Journal of Ophthalmology
spelling doaj.art-bb680518977240b8a4dee986990cc9322022-12-21T19:17:09ZengWolters Kluwer Medknow PublicationsIndian Journal of Ophthalmology0301-47381998-36892017-01-0165757958310.4103/ijo.IJO_31_17Comparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplastyOded OhanaDavid VarssanoGabi ShemeshPurpose: Post-Descemet stripping endothelial keratoplasty (DSEK) patients are prone for intraocular pressure (IOP) elevations and glaucoma. Corneal characteristics influence various IOP measuring devices in various ways. The aim of this study was to evaluate the agreement between four different IOP measuring devices: Goldmann applanation tonometer (GAT), I-care pro, Tonopen XL, and Schiotz tonometr in patients who underwent DSEK. Methods: This was a prospective comparative study using a convenience cohort of post-DSEK patients with compact grafts. Post-DSEK patients had IOP measured using GAT, I-care Pro, Tonopen XL, and Schiotz tonometer. Measurements were compared and agreement assessed. Wilcoxon signed-rank test was used for comparison of means as variables did not show a normal distribution. Bland–Altman plots were used for assessing agreement. Results: Thirty eyes of 24 patients were included in the study. Mean time from DSEK surgery was 25.31 ± 13.05 months. Mean IOP with GAT, I-care pro, Tonopen XL, and Schiotz tonometer was 13.99 ± 3.76, 13.92 ± 3.36, 13.31 ± 3.89, and 12.83 ± 4.07, respectively. GAT, I-care pro, and Tonopen XL had similar mean IOP measurements (P = 0.135 and P = 0.551, respectively), while Schiotz tonometry measurements were higher (P = 0.046). Bland–Altman plots show good agreement between GAT, Tonopen XL, and I-care pro. GAT and Schiotz tonometry show less agreement, with large variations in the differences of measured IOP. Conclusions: IOP measurements in post-DSEK patients showed good agreement between GAT and either Tonopen XL or I-care pro. Schiotz tonometer has large variations in this patient group. IOP measurements and IOP difference between devices were not dependent on central corneal thickness.http://www.ijo.in/article.asp?issn=0301-4738;year=2017;volume=65;issue=7;spage=579;epage=583;aulast=OhanaDescemet stripping endothelial keratoplastyI-careintraocular pressurerebound tonometrySchiotzTonometryTonopen
spellingShingle Oded Ohana
David Varssano
Gabi Shemesh
Comparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplasty
Indian Journal of Ophthalmology
Descemet stripping endothelial keratoplasty
I-care
intraocular pressure
rebound tonometry
Schiotz
Tonometry
Tonopen
title Comparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplasty
title_full Comparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplasty
title_fullStr Comparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplasty
title_full_unstemmed Comparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplasty
title_short Comparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplasty
title_sort comparison of intraocular pressure measurements using goldmann tonometer i care pro tonopen xl and schiotz tonometer in patients after descemet stripping endothelial keratoplasty
topic Descemet stripping endothelial keratoplasty
I-care
intraocular pressure
rebound tonometry
Schiotz
Tonometry
Tonopen
url http://www.ijo.in/article.asp?issn=0301-4738;year=2017;volume=65;issue=7;spage=579;epage=583;aulast=Ohana
work_keys_str_mv AT odedohana comparisonofintraocularpressuremeasurementsusinggoldmanntonometericareprotonopenxlandschiotztonometerinpatientsafterdescemetstrippingendothelialkeratoplasty
AT davidvarssano comparisonofintraocularpressuremeasurementsusinggoldmanntonometericareprotonopenxlandschiotztonometerinpatientsafterdescemetstrippingendothelialkeratoplasty
AT gabishemesh comparisonofintraocularpressuremeasurementsusinggoldmanntonometericareprotonopenxlandschiotztonometerinpatientsafterdescemetstrippingendothelialkeratoplasty