Validity and reliability of total body volume and relative body fat mass from a 3-dimensional photonic body surface scanner.

Three-dimensional photonic body surface scanners (3DPS) feature a tool to estimate total body volume (BV) from 3D images of the human body, from which the relative body fat mass (%BF) can be calculated. However, information on validity and reliability of these measurements for application in epidemi...

Full description

Bibliographic Details
Main Authors: Carolin Adler, Astrid Steinbrecher, Lina Jaeschke, Anja Mähler, Michael Boschmann, Stephanie Jeran, Tobias Pischon
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2017-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC5495384?pdf=render
_version_ 1818691772584296448
author Carolin Adler
Astrid Steinbrecher
Lina Jaeschke
Anja Mähler
Michael Boschmann
Stephanie Jeran
Tobias Pischon
author_facet Carolin Adler
Astrid Steinbrecher
Lina Jaeschke
Anja Mähler
Michael Boschmann
Stephanie Jeran
Tobias Pischon
author_sort Carolin Adler
collection DOAJ
description Three-dimensional photonic body surface scanners (3DPS) feature a tool to estimate total body volume (BV) from 3D images of the human body, from which the relative body fat mass (%BF) can be calculated. However, information on validity and reliability of these measurements for application in epidemiological studies is limited.Validity was assessed among 32 participants (men, 50%) aged 20-58 years. BV and %BF were assessed using a 3DPS (VitusSmart XXL) and air displacement plethysmography (ADP) with a BOD POD® device using equations by Siri and Brozek. Three scans were obtained per participant (standard, relaxed, exhaled scan). Validity was evaluated based on the agreement of 3DPS with ADP using Bland Altman plots, correlation analysis and Wilcoxon signed ranks test for paired samples. Reliability was investigated in a separate sample of 18 participants (men, 67%) aged 25-66 years using intraclass correlation coefficients (ICC) based on two repeated 3DPS measurements four weeks apart.Mean BV and %BF were higher using 3DPS compared to ADP, (3DPS-ADP BV difference 1.1 ± 0.9 L, p<0.01; %BF difference 7.0 ± 5.6, p<0.01), yet the disagreement was not associated with gender, age or body mass index (BMI). Reliability was excellent for 3DPS BV (ICC, 0.998) and good for 3DPS %BF (ICC, 0.982). Results were similar for the standard scan and the relaxed scan but somewhat weaker for the exhaled scan.Although BV and %BF are higher than ADP measurements, our data indicate good validity and reliability for an application of 3DPS in epidemiological studies.
first_indexed 2024-12-17T12:47:12Z
format Article
id doaj.art-bb772d59b6b64d5d97eed881c4b55f7c
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-12-17T12:47:12Z
publishDate 2017-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-bb772d59b6b64d5d97eed881c4b55f7c2022-12-21T21:47:41ZengPublic Library of Science (PLoS)PLoS ONE1932-62032017-01-01127e018020110.1371/journal.pone.0180201Validity and reliability of total body volume and relative body fat mass from a 3-dimensional photonic body surface scanner.Carolin AdlerAstrid SteinbrecherLina JaeschkeAnja MählerMichael BoschmannStephanie JeranTobias PischonThree-dimensional photonic body surface scanners (3DPS) feature a tool to estimate total body volume (BV) from 3D images of the human body, from which the relative body fat mass (%BF) can be calculated. However, information on validity and reliability of these measurements for application in epidemiological studies is limited.Validity was assessed among 32 participants (men, 50%) aged 20-58 years. BV and %BF were assessed using a 3DPS (VitusSmart XXL) and air displacement plethysmography (ADP) with a BOD POD® device using equations by Siri and Brozek. Three scans were obtained per participant (standard, relaxed, exhaled scan). Validity was evaluated based on the agreement of 3DPS with ADP using Bland Altman plots, correlation analysis and Wilcoxon signed ranks test for paired samples. Reliability was investigated in a separate sample of 18 participants (men, 67%) aged 25-66 years using intraclass correlation coefficients (ICC) based on two repeated 3DPS measurements four weeks apart.Mean BV and %BF were higher using 3DPS compared to ADP, (3DPS-ADP BV difference 1.1 ± 0.9 L, p<0.01; %BF difference 7.0 ± 5.6, p<0.01), yet the disagreement was not associated with gender, age or body mass index (BMI). Reliability was excellent for 3DPS BV (ICC, 0.998) and good for 3DPS %BF (ICC, 0.982). Results were similar for the standard scan and the relaxed scan but somewhat weaker for the exhaled scan.Although BV and %BF are higher than ADP measurements, our data indicate good validity and reliability for an application of 3DPS in epidemiological studies.http://europepmc.org/articles/PMC5495384?pdf=render
spellingShingle Carolin Adler
Astrid Steinbrecher
Lina Jaeschke
Anja Mähler
Michael Boschmann
Stephanie Jeran
Tobias Pischon
Validity and reliability of total body volume and relative body fat mass from a 3-dimensional photonic body surface scanner.
PLoS ONE
title Validity and reliability of total body volume and relative body fat mass from a 3-dimensional photonic body surface scanner.
title_full Validity and reliability of total body volume and relative body fat mass from a 3-dimensional photonic body surface scanner.
title_fullStr Validity and reliability of total body volume and relative body fat mass from a 3-dimensional photonic body surface scanner.
title_full_unstemmed Validity and reliability of total body volume and relative body fat mass from a 3-dimensional photonic body surface scanner.
title_short Validity and reliability of total body volume and relative body fat mass from a 3-dimensional photonic body surface scanner.
title_sort validity and reliability of total body volume and relative body fat mass from a 3 dimensional photonic body surface scanner
url http://europepmc.org/articles/PMC5495384?pdf=render
work_keys_str_mv AT carolinadler validityandreliabilityoftotalbodyvolumeandrelativebodyfatmassfroma3dimensionalphotonicbodysurfacescanner
AT astridsteinbrecher validityandreliabilityoftotalbodyvolumeandrelativebodyfatmassfroma3dimensionalphotonicbodysurfacescanner
AT linajaeschke validityandreliabilityoftotalbodyvolumeandrelativebodyfatmassfroma3dimensionalphotonicbodysurfacescanner
AT anjamahler validityandreliabilityoftotalbodyvolumeandrelativebodyfatmassfroma3dimensionalphotonicbodysurfacescanner
AT michaelboschmann validityandreliabilityoftotalbodyvolumeandrelativebodyfatmassfroma3dimensionalphotonicbodysurfacescanner
AT stephaniejeran validityandreliabilityoftotalbodyvolumeandrelativebodyfatmassfroma3dimensionalphotonicbodysurfacescanner
AT tobiaspischon validityandreliabilityoftotalbodyvolumeandrelativebodyfatmassfroma3dimensionalphotonicbodysurfacescanner