Study on the effect of a cold environment on the quality of three video laryngoscopes: McGrath MAC, GlideScope Ranger, and Pentax Airway Scope

Objective Several environmental factors influence the prehospital use of video laryngoscopes (VLs). For example, fogging of the VL lens can occur in cold environments, and the low temperature can cause the VLs to malfunction. As relevant research on the effect of environment on VLs is lacking, we ai...

Full description

Bibliographic Details
Main Authors: Jin Won Park, Hyuk Joong Choi
Format: Article
Language:English
Published: The Korean Society of Emergency Medicine 2019-12-01
Series:Clinical and Experimental Emergency Medicine
Subjects:
Online Access:http://www.ceemjournal.org/upload/pdf/ceem-18-063.pdf
_version_ 1797895569171021824
author Jin Won Park
Hyuk Joong Choi
author_facet Jin Won Park
Hyuk Joong Choi
author_sort Jin Won Park
collection DOAJ
description Objective Several environmental factors influence the prehospital use of video laryngoscopes (VLs). For example, fogging of the VL lens can occur in cold environments, and the low temperature can cause the VLs to malfunction. As relevant research on the effect of environment on VLs is lacking, we aimed to study the effect of a cold environment on three commonly used VLs. Methods McGrath MAC, Pentax Airway Scope (AWS), and GlideScope Ranger were exposed to temperatures of -5°C, -10°C, -20°C, and -25°C for 1 hour each and then applied to a manikin in a thermohydrostat room 5 times. Immediately after turning on the power and inserting the blade, the time until an appropriate glottic image appeared on the screen was measured. Results McGrath MAC was able to accomplish immediate intubation regardless of the temperature drop. However, GlideScope Ranger required an average of 4.9 seconds (-5°C to -20°C) and 10.1 seconds (-25°C) until appropriate images were obtained for intubation. AWS showed adequate image acquisition immediately after blade insertion despite slight fogging at -20°C, but at -25°C, images suitable for intubation did not appear on the screen for an average of 4.7 minutes. Conclusion All three devices appear to be usable without any limitations up to -20°C. However, GlideScope Ranger and AWS may not produce images immediately at temperatures below -25°C. Thus, medical practitioners performing VL in a cold environment should be aware of the characteristics of the VL devices in advance.
first_indexed 2024-04-10T07:29:08Z
format Article
id doaj.art-bc0f6d132f83435fad793ccf46cb595c
institution Directory Open Access Journal
issn 2383-4625
language English
last_indexed 2024-04-10T07:29:08Z
publishDate 2019-12-01
publisher The Korean Society of Emergency Medicine
record_format Article
series Clinical and Experimental Emergency Medicine
spelling doaj.art-bc0f6d132f83435fad793ccf46cb595c2023-02-24T04:20:17ZengThe Korean Society of Emergency MedicineClinical and Experimental Emergency Medicine2383-46252019-12-016435135510.15441/ceem.18.063256Study on the effect of a cold environment on the quality of three video laryngoscopes: McGrath MAC, GlideScope Ranger, and Pentax Airway ScopeJin Won Park0Hyuk Joong Choi1 Department of Emergency Medicine, Hanyang University College of Medicine, Seoul, Korea Department of Emergency Medicine, Hanyang University College of Medicine, Seoul, KoreaObjective Several environmental factors influence the prehospital use of video laryngoscopes (VLs). For example, fogging of the VL lens can occur in cold environments, and the low temperature can cause the VLs to malfunction. As relevant research on the effect of environment on VLs is lacking, we aimed to study the effect of a cold environment on three commonly used VLs. Methods McGrath MAC, Pentax Airway Scope (AWS), and GlideScope Ranger were exposed to temperatures of -5°C, -10°C, -20°C, and -25°C for 1 hour each and then applied to a manikin in a thermohydrostat room 5 times. Immediately after turning on the power and inserting the blade, the time until an appropriate glottic image appeared on the screen was measured. Results McGrath MAC was able to accomplish immediate intubation regardless of the temperature drop. However, GlideScope Ranger required an average of 4.9 seconds (-5°C to -20°C) and 10.1 seconds (-25°C) until appropriate images were obtained for intubation. AWS showed adequate image acquisition immediately after blade insertion despite slight fogging at -20°C, but at -25°C, images suitable for intubation did not appear on the screen for an average of 4.7 minutes. Conclusion All three devices appear to be usable without any limitations up to -20°C. However, GlideScope Ranger and AWS may not produce images immediately at temperatures below -25°C. Thus, medical practitioners performing VL in a cold environment should be aware of the characteristics of the VL devices in advance.http://www.ceemjournal.org/upload/pdf/ceem-18-063.pdfintubation, intratrachealcold temperaturelaryngoscopes
spellingShingle Jin Won Park
Hyuk Joong Choi
Study on the effect of a cold environment on the quality of three video laryngoscopes: McGrath MAC, GlideScope Ranger, and Pentax Airway Scope
Clinical and Experimental Emergency Medicine
intubation, intratracheal
cold temperature
laryngoscopes
title Study on the effect of a cold environment on the quality of three video laryngoscopes: McGrath MAC, GlideScope Ranger, and Pentax Airway Scope
title_full Study on the effect of a cold environment on the quality of three video laryngoscopes: McGrath MAC, GlideScope Ranger, and Pentax Airway Scope
title_fullStr Study on the effect of a cold environment on the quality of three video laryngoscopes: McGrath MAC, GlideScope Ranger, and Pentax Airway Scope
title_full_unstemmed Study on the effect of a cold environment on the quality of three video laryngoscopes: McGrath MAC, GlideScope Ranger, and Pentax Airway Scope
title_short Study on the effect of a cold environment on the quality of three video laryngoscopes: McGrath MAC, GlideScope Ranger, and Pentax Airway Scope
title_sort study on the effect of a cold environment on the quality of three video laryngoscopes mcgrath mac glidescope ranger and pentax airway scope
topic intubation, intratracheal
cold temperature
laryngoscopes
url http://www.ceemjournal.org/upload/pdf/ceem-18-063.pdf
work_keys_str_mv AT jinwonpark studyontheeffectofacoldenvironmentonthequalityofthreevideolaryngoscopesmcgrathmacglidescoperangerandpentaxairwayscope
AT hyukjoongchoi studyontheeffectofacoldenvironmentonthequalityofthreevideolaryngoscopesmcgrathmacglidescoperangerandpentaxairwayscope