A High Power Factor Symmetrical Switched-Mode Power Supply.

This paper proposes a switched-mode power supply (SMPS) with power factor correction. A preregulator boost converter is employed in order to obtain universal line voltage and reduced harmonic content of the input current. Two dc/dc forward converters are used so that two symmetrical output stages ar...

Full description

Bibliographic Details
Main Authors: Fernando Lessa Tofoli, Carlos Alberto Gallo
Format: Article
Language:Portuguese
Published: Universidade de Fortaleza 2009-06-01
Series:Revista Tecnologia
Subjects:
Online Access:https://periodicos.unifor.br/tec/article/view/105
_version_ 1818788772778606592
author Fernando Lessa Tofoli
Carlos Alberto Gallo
author_facet Fernando Lessa Tofoli
Carlos Alberto Gallo
author_sort Fernando Lessa Tofoli
collection DOAJ
description This paper proposes a switched-mode power supply (SMPS) with power factor correction. A preregulator boost converter is employed in order to obtain universal line voltage and reduced harmonic content of the input current. Two dc/dc forward converters are used so that two symmetrical output stages are obtained. The association of the aforementioned ac/dc and dc/dc converters results in a high power factor SMPS.
first_indexed 2024-12-18T14:28:59Z
format Article
id doaj.art-bc6b37fb83ac4efbbe3f7c3f593ce03f
institution Directory Open Access Journal
issn 0101-8191
2318-0730
language Portuguese
last_indexed 2024-12-18T14:28:59Z
publishDate 2009-06-01
publisher Universidade de Fortaleza
record_format Article
series Revista Tecnologia
spelling doaj.art-bc6b37fb83ac4efbbe3f7c3f593ce03f2022-12-21T21:04:38ZporUniversidade de FortalezaRevista Tecnologia0101-81912318-07302009-06-01261103A High Power Factor Symmetrical Switched-Mode Power Supply.Fernando Lessa Tofoli0Carlos Alberto Gallo1Universidade Federal de UberlândiaUniversidade Federal de UberlândiaThis paper proposes a switched-mode power supply (SMPS) with power factor correction. A preregulator boost converter is employed in order to obtain universal line voltage and reduced harmonic content of the input current. Two dc/dc forward converters are used so that two symmetrical output stages are obtained. The association of the aforementioned ac/dc and dc/dc converters results in a high power factor SMPS.https://periodicos.unifor.br/tec/article/view/105correção de fator de potência, fontes chaveadas.
spellingShingle Fernando Lessa Tofoli
Carlos Alberto Gallo
A High Power Factor Symmetrical Switched-Mode Power Supply.
Revista Tecnologia
correção de fator de potência, fontes chaveadas.
title A High Power Factor Symmetrical Switched-Mode Power Supply.
title_full A High Power Factor Symmetrical Switched-Mode Power Supply.
title_fullStr A High Power Factor Symmetrical Switched-Mode Power Supply.
title_full_unstemmed A High Power Factor Symmetrical Switched-Mode Power Supply.
title_short A High Power Factor Symmetrical Switched-Mode Power Supply.
title_sort high power factor symmetrical switched mode power supply
topic correção de fator de potência, fontes chaveadas.
url https://periodicos.unifor.br/tec/article/view/105
work_keys_str_mv AT fernandolessatofoli ahighpowerfactorsymmetricalswitchedmodepowersupply
AT carlosalbertogallo ahighpowerfactorsymmetricalswitchedmodepowersupply
AT fernandolessatofoli highpowerfactorsymmetricalswitchedmodepowersupply
AT carlosalbertogallo highpowerfactorsymmetricalswitchedmodepowersupply