Evaluation of reproductibility and detection limit of CaSO4: dy radiation detectors
Measurement response of thermoluminescent dosimeter, TLD, used by workers or placed at positions where gamma radiation field could be in action affecting biological tissues, should be completely characterized, in order to achieve the radiation quantity with precision and confidence. Among the evalua...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Instituto de Tecnologia do Paraná (Tecpar)
2006-01-01
|
Series: | Brazilian Archives of Biology and Technology |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132006000200009 |
_version_ | 1818620504317100032 |
---|---|
author | José Eduardo Manzoli Vicente de Paulo de Campos Mirian Saori Doi |
author_facet | José Eduardo Manzoli Vicente de Paulo de Campos Mirian Saori Doi |
author_sort | José Eduardo Manzoli |
collection | DOAJ |
description | Measurement response of thermoluminescent dosimeter, TLD, used by workers or placed at positions where gamma radiation field could be in action affecting biological tissues, should be completely characterized, in order to achieve the radiation quantity with precision and confidence. Among the evaluations concerned to its characterization, the detector reproductibility is of fundamental importance, because detectors present inside the TLD will be used many times in routine. Reproductibility is studied by repeated exposure to the same radiation field. The minimum detection limit is another important characteristics of a TLD. In this work evaluations of reproductibility and minimum detection are presented, for dosimeters produced at IPEN.<br>A resposta de um dosímetro termoluminescente, TLD, utilizado por um trabalhador ou colocado em um local que possa estar sujeito a um campo de radiação gama afetando tecidos biológicos, deve ser muito bem caracterizada afim de se obter o valor da grandeza de medição da radiação desejada, com precisão e confiança. Entre as avaliações envolvidas nesta caracterização encontra-se sua reprodutividade, de fundamental importância pois o detector é re-utilizado várias vezes na rotina de serviços. A reprodutividade é estudada pela exposição do detector a um mesmo campo de radiação repetidas vezes. O seu limite de detecção é outra importante característica. Neste trabalho são apresentadas avaliações da reprodutividade e do limite de detecção dos detectores produzidos no IPEN. |
first_indexed | 2024-12-16T17:54:26Z |
format | Article |
id | doaj.art-bd094047792b46ba8bf096aa3faaa581 |
institution | Directory Open Access Journal |
issn | 1516-8913 1678-4324 |
language | English |
last_indexed | 2024-12-16T17:54:26Z |
publishDate | 2006-01-01 |
publisher | Instituto de Tecnologia do Paraná (Tecpar) |
record_format | Article |
series | Brazilian Archives of Biology and Technology |
spelling | doaj.art-bd094047792b46ba8bf096aa3faaa5812022-12-21T22:22:12ZengInstituto de Tecnologia do Paraná (Tecpar)Brazilian Archives of Biology and Technology1516-89131678-43242006-01-0149spe535810.1590/S1516-89132006000200009Evaluation of reproductibility and detection limit of CaSO4: dy radiation detectorsJosé Eduardo ManzoliVicente de Paulo de CamposMirian Saori DoiMeasurement response of thermoluminescent dosimeter, TLD, used by workers or placed at positions where gamma radiation field could be in action affecting biological tissues, should be completely characterized, in order to achieve the radiation quantity with precision and confidence. Among the evaluations concerned to its characterization, the detector reproductibility is of fundamental importance, because detectors present inside the TLD will be used many times in routine. Reproductibility is studied by repeated exposure to the same radiation field. The minimum detection limit is another important characteristics of a TLD. In this work evaluations of reproductibility and minimum detection are presented, for dosimeters produced at IPEN.<br>A resposta de um dosímetro termoluminescente, TLD, utilizado por um trabalhador ou colocado em um local que possa estar sujeito a um campo de radiação gama afetando tecidos biológicos, deve ser muito bem caracterizada afim de se obter o valor da grandeza de medição da radiação desejada, com precisão e confiança. Entre as avaliações envolvidas nesta caracterização encontra-se sua reprodutividade, de fundamental importância pois o detector é re-utilizado várias vezes na rotina de serviços. A reprodutividade é estudada pela exposição do detector a um mesmo campo de radiação repetidas vezes. O seu limite de detecção é outra importante característica. Neste trabalho são apresentadas avaliações da reprodutividade e do limite de detecção dos detectores produzidos no IPEN.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132006000200009Detector selectionpersonal dosimetryenvironmental dosimetry |
spellingShingle | José Eduardo Manzoli Vicente de Paulo de Campos Mirian Saori Doi Evaluation of reproductibility and detection limit of CaSO4: dy radiation detectors Brazilian Archives of Biology and Technology Detector selection personal dosimetry environmental dosimetry |
title | Evaluation of reproductibility and detection limit of CaSO4: dy radiation detectors |
title_full | Evaluation of reproductibility and detection limit of CaSO4: dy radiation detectors |
title_fullStr | Evaluation of reproductibility and detection limit of CaSO4: dy radiation detectors |
title_full_unstemmed | Evaluation of reproductibility and detection limit of CaSO4: dy radiation detectors |
title_short | Evaluation of reproductibility and detection limit of CaSO4: dy radiation detectors |
title_sort | evaluation of reproductibility and detection limit of caso4 dy radiation detectors |
topic | Detector selection personal dosimetry environmental dosimetry |
url | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132006000200009 |
work_keys_str_mv | AT joseeduardomanzoli evaluationofreproductibilityanddetectionlimitofcaso4dyradiationdetectors AT vicentedepaulodecampos evaluationofreproductibilityanddetectionlimitofcaso4dyradiationdetectors AT miriansaoridoi evaluationofreproductibilityanddetectionlimitofcaso4dyradiationdetectors |