Shape-memory sawtooth-arm embracing clamp used in complex femoral revision hip arthroplasty for stem stability: average 9-year follow-up study

Abstract Background Nickel-Titanium shape-memory sawtooth-arm embracing clamps (SSECs) have been used in revision total hip arthroplasties (rTHAs) to protect stem stability. This study was to introduce this technique and report its mid to long-term clinical and radiographic outcomes. Methods We retr...

Full description

Bibliographic Details
Main Authors: Yi Hu, Zhengquan Xu, Hua Qiao, Keyu Kong, Huiwu Li, Jingwei Zhang
Format: Article
Language:English
Published: BMC 2023-12-01
Series:BMC Musculoskeletal Disorders
Subjects:
Online Access:https://doi.org/10.1186/s12891-023-07080-8
_version_ 1797388564271464448
author Yi Hu
Zhengquan Xu
Hua Qiao
Keyu Kong
Huiwu Li
Jingwei Zhang
author_facet Yi Hu
Zhengquan Xu
Hua Qiao
Keyu Kong
Huiwu Li
Jingwei Zhang
author_sort Yi Hu
collection DOAJ
description Abstract Background Nickel-Titanium shape-memory sawtooth-arm embracing clamps (SSECs) have been used in revision total hip arthroplasties (rTHAs) to protect stem stability. This study was to introduce this technique and report its mid to long-term clinical and radiographic outcomes. Methods We retrospectively reviewed all patients implanted with SSECs in our department from January 2008 to December 2015. 41 patients (41 hips) were finally included. Radiographs and Harris hip scores (HHS) were collected. Radiographs were blindly analyzed for evidence of loosening, subsidence and stress shielding. HHS were compared to previous records by student’s t tests. The average follow-up period was 9.3 years. Results All stems were stably fixed with no signs of loosening. The mean stem subsidence was 0.9 mm (range, 0 to 3 mm). Only one patient (2.4%) demonstrated the fourth degree of stress shielding, with the others none or minor bone resorption. The mean HHS at the final follow-up was 84.2 (range, 81 to 91), which was improved from 17.4 (range, 0 to 37) before surgery. No implant failures or re-revisions occurred. Dislocation occurred in 1 case during the follow-up period. Conclusions The SSEC protected stem fixation and achieved favorable clinical and radiographic outcomes in this 9-year follow-up study. It offered an additional extramedullary fixation option for surgeons to choose from in treating complex femoral revision arthroplasties.
first_indexed 2024-03-08T22:42:38Z
format Article
id doaj.art-bda770671c0e4b34aa289aaed41904a1
institution Directory Open Access Journal
issn 1471-2474
language English
last_indexed 2024-03-08T22:42:38Z
publishDate 2023-12-01
publisher BMC
record_format Article
series BMC Musculoskeletal Disorders
spelling doaj.art-bda770671c0e4b34aa289aaed41904a12023-12-17T12:04:15ZengBMCBMC Musculoskeletal Disorders1471-24742023-12-012411810.1186/s12891-023-07080-8Shape-memory sawtooth-arm embracing clamp used in complex femoral revision hip arthroplasty for stem stability: average 9-year follow-up studyYi Hu0Zhengquan Xu1Hua Qiao2Keyu Kong3Huiwu Li4Jingwei Zhang5Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People’s Hospital, Shanghai Jiaotong University School of MedicineDepartment of Orthopaedic Surgery, Suzhou Hospital, Nanjing Medical UniversityShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People’s Hospital, Shanghai Jiaotong University School of MedicineShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People’s Hospital, Shanghai Jiaotong University School of MedicineShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People’s Hospital, Shanghai Jiaotong University School of MedicineShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People’s Hospital, Shanghai Jiaotong University School of MedicineAbstract Background Nickel-Titanium shape-memory sawtooth-arm embracing clamps (SSECs) have been used in revision total hip arthroplasties (rTHAs) to protect stem stability. This study was to introduce this technique and report its mid to long-term clinical and radiographic outcomes. Methods We retrospectively reviewed all patients implanted with SSECs in our department from January 2008 to December 2015. 41 patients (41 hips) were finally included. Radiographs and Harris hip scores (HHS) were collected. Radiographs were blindly analyzed for evidence of loosening, subsidence and stress shielding. HHS were compared to previous records by student’s t tests. The average follow-up period was 9.3 years. Results All stems were stably fixed with no signs of loosening. The mean stem subsidence was 0.9 mm (range, 0 to 3 mm). Only one patient (2.4%) demonstrated the fourth degree of stress shielding, with the others none or minor bone resorption. The mean HHS at the final follow-up was 84.2 (range, 81 to 91), which was improved from 17.4 (range, 0 to 37) before surgery. No implant failures or re-revisions occurred. Dislocation occurred in 1 case during the follow-up period. Conclusions The SSEC protected stem fixation and achieved favorable clinical and radiographic outcomes in this 9-year follow-up study. It offered an additional extramedullary fixation option for surgeons to choose from in treating complex femoral revision arthroplasties.https://doi.org/10.1186/s12891-023-07080-8Shape-memory sawtooth-arm embracing clampRevision hip arthroplastyFemoral revisionMid to long-term follow-up
spellingShingle Yi Hu
Zhengquan Xu
Hua Qiao
Keyu Kong
Huiwu Li
Jingwei Zhang
Shape-memory sawtooth-arm embracing clamp used in complex femoral revision hip arthroplasty for stem stability: average 9-year follow-up study
BMC Musculoskeletal Disorders
Shape-memory sawtooth-arm embracing clamp
Revision hip arthroplasty
Femoral revision
Mid to long-term follow-up
title Shape-memory sawtooth-arm embracing clamp used in complex femoral revision hip arthroplasty for stem stability: average 9-year follow-up study
title_full Shape-memory sawtooth-arm embracing clamp used in complex femoral revision hip arthroplasty for stem stability: average 9-year follow-up study
title_fullStr Shape-memory sawtooth-arm embracing clamp used in complex femoral revision hip arthroplasty for stem stability: average 9-year follow-up study
title_full_unstemmed Shape-memory sawtooth-arm embracing clamp used in complex femoral revision hip arthroplasty for stem stability: average 9-year follow-up study
title_short Shape-memory sawtooth-arm embracing clamp used in complex femoral revision hip arthroplasty for stem stability: average 9-year follow-up study
title_sort shape memory sawtooth arm embracing clamp used in complex femoral revision hip arthroplasty for stem stability average 9 year follow up study
topic Shape-memory sawtooth-arm embracing clamp
Revision hip arthroplasty
Femoral revision
Mid to long-term follow-up
url https://doi.org/10.1186/s12891-023-07080-8
work_keys_str_mv AT yihu shapememorysawtootharmembracingclampusedincomplexfemoralrevisionhiparthroplastyforstemstabilityaverage9yearfollowupstudy
AT zhengquanxu shapememorysawtootharmembracingclampusedincomplexfemoralrevisionhiparthroplastyforstemstabilityaverage9yearfollowupstudy
AT huaqiao shapememorysawtootharmembracingclampusedincomplexfemoralrevisionhiparthroplastyforstemstabilityaverage9yearfollowupstudy
AT keyukong shapememorysawtootharmembracingclampusedincomplexfemoralrevisionhiparthroplastyforstemstabilityaverage9yearfollowupstudy
AT huiwuli shapememorysawtootharmembracingclampusedincomplexfemoralrevisionhiparthroplastyforstemstabilityaverage9yearfollowupstudy
AT jingweizhang shapememorysawtootharmembracingclampusedincomplexfemoralrevisionhiparthroplastyforstemstabilityaverage9yearfollowupstudy